KDS6-0.2TR
Remote Control 45
4.4
Message Table
A table of the remote interface messages is given below. R/W represents the query
message (R) or command message (W).
Table 4-3
†
1: For more information, refer to the detailed description for each message.
Header
Data
Function and response data
R/W
Min
Max
Resolution
Unit
1
SILent
W
OFF(0)
ON(1)
–
–
Acknowledge message (RS-232C)
2
*RST
W
–
–
–
–
Device initialization (resets to factory-settings)
3
*IDN?
R
–
–
–
–
“KIKUSUI ELECTRONICS CORP.,KDS6-0.2TR,0,x.xx”
is returned.
(x.xx is the version No.)
4
ERR?
R
–
–
–
–
An error register value is returned to clear the error register.
5
*STB?
R
–
–
–
–
A status byte register is read out.
6
*SRE
R/W
0
255
1
–
Setting of service request enable register/read-out of setting
value
7
*CLS
W
–
–
–
–
Clearing of status byte register
8
V1Set
R/W
0.0000
6.5000
0.0001
V
Channel-1 voltage setting or read-out of setting value
9
V2Set
R/W
0.0000
6.5000
0.0001
V
Channel-2 voltage setting or read-out of setting value
10 V3Set
R/W
0.0000
6.5000
0.0001
V
Channel-3 voltage setting or read-out of setting value
11
VSET
R/W
0.0000
6.5000
0.0001
V
En-bloc setting or read-out of Channel-1 to Channel-3 out-
put voltages
12 I1Out?
R
–
–
†
1
mA
Read-out of Channel-1 output current value
If OCP has occurred, “CH<n>OCP” is returned (n = 1 to 3).
13 I2Out?
R
–
–
†
1
mA
Read-out of Channel-2 output current value
If OCP has occurred, “CH<n>OCP” is returned (n = 1 to 3).
14 I3Out?
R
–
–
†
1
mA
Read-out of Channel-3 output current value
If OCP has occurred, “CH<n>OCP” is returned (n = 1 to 3).
15 IOUT?
R
–
–
†
1
mA
En-bloc read-out of Channel-1 to Channel-3 output volt-
ages
If OCP has occurred, “CH<n>OCP” is returned (n = 1 to 3).
16 OUTPut
R/W
OFF(0)
ON(1)
1
–
On/off or status read-out of all-channel outputs
To clear OCP, OUTPut Off or OUTPut 0 is sent.
17 RANGeset
R/W
0
1
1
–
Switching/inquiry of current range of Channel 1
0:10 mA 1:200 mA
18 SAMPlerate
R/W
0
1
1
–
Switching the sampling rate of the output ammeter
0: Normal mode
1: High-speed mode
19 KEYLock
R/W
OFF(0)
ON(1)
1
–
Locks all keys but the LOCAL key.
20 ACHSel
R/W
0
1
1
–
On/off setting of the function to switch panel indication
with every voltage setting or current read-out
Summary of Contents for KDS6-0.2TR
Page 1: ...OPERATION MANUAL Precision DC Source Part No Z1 003 132 I0040701 May 2021 KDS6 0 2TR ...
Page 4: ...ii KDS6 0 2TR ...
Page 8: ...4 Safety Precautions KDS6 0 2TR ...
Page 12: ...8 Introduction KDS6 0 2TR ...
Page 22: ...18 Names and Functions of Parts KDS6 0 2TR ...
Page 30: ...26 Basic Operations and Connections KDS6 0 2TR ...
Page 52: ...48 Maintenance and Calibration KDS6 0 2TR ...
Page 58: ...54 Index KDS6 0 2TR ...
Page 59: ......