KIESELMANN GmbH | Operating instruction
Technical data | 5
6164_EN
11 / 21
5.3 Pneumatic actuator
Type 76
6162 076 900 – 032
Type 104
6162 104 900 – 032
Total height
85 mm
Total height
97 mm
Installation height
67 mm
Installation height
83 mm
Outside diameter
76 mm
Outside diameter
104 mm
Stroke
9 mm
Stroke
9 mm
Lifting force *
)
1.844 N
Lifting force *
)
3.822 N
Weight
1,05 kg
Weight
2,1 kg
*
)
at control air pressure: 5,0 bar
(g)
The selection of the actuator size can be made according to the following table:
Valve size
Control air
Actuator size at tank overpressure
0.5 bar
0.7 bar
1.0 bar
1.5 bar
2.0 bar
DN 50
5 bar
Ø 76
Ø 76
Ø 76
Ø 76
Ø 76
DN 65
5 bar
Ø 76
Ø 76
Ø 76
Ø 76
Ø 76
DN 80
5 bar
Ø 76
Ø 76
Ø 76
Ø 76
Ø 76
DN 100
5 bar
Ø 76
Ø 76
Ø 76
Ø 76
Ø 104
DN 125
5 bar
Ø 76
Ø 76
Ø 76
Ø 104
Ø 104
DN 150
5 bar
Ø 76
Ø 76
Ø 104
Ø 104
-
DN 200
5 bar
Ø 76
Ø 104
Ø 104
-
-
DN 250
5 bar
Ø 104
Ø 104
-
-
-
5.4 heating system
The heating of the vacuum valves via resistance heating cable with a defined heating zone, which
run in an annular groove in the housing flange.
The heat tracing must be operated with a temperature control, so that exceeding the limit temperat-
ures of the electric heating cables and the products to be heated is not exceeded. In the hole (B), a
sensor (Ø5mm) can be used for temperature monitoring.
Valve size Usable cable
length
Item number
Heating cable
B
DN 50
-
-
DN 65
382 mm
8615 483 038 – 000
DN 80
482 mm
8615 483 048 – 000
DN 100
525 mm
8615 483 052 – 000
DN 125
622 mm
8615 483 062 – 000
DN 150
738 mm
8615 483 073 – 000
DN 200
888 mm
8615 483 088 – 000
DN 250
1.074 mm
8615 483 107 – 000
-
1.100 mm
8615 483 110 – 000
www.sks-online.com
www.sks-webshop.com