Model RF-SM-ACDC has a HUSH

®

button that is extremely useful in a kitchen

area or other areas prone to nuisance alarms. For more information, refer to
Section 4 OPERATION AND TESTING. If the alarm does sound, check for fires
first. If a fire is discovered, get out and call the fire department. If no fire is pres-
ent, check to see if one of the reasons listed in Section 2 may have caused the
alarm.

In rare occasions, interference from other electronic devices may cause nuisance
alarms. If you do get nuisance alarms, please refer to the trouble-shooting guide
at the end of this and each of your Kidde Wireless products’ user’s guides.

6. MAINTENANCE 

ALARM REMOVAL

IF THE SMOKE ALARM’S TAMPER RESIST FEATURE HAS BEEN ACTIVATED,
REFER TO THE PARAGRAPH ON SMOKE ALARM TAMPER RESIST FEATURE
IN SECTION 3 FOR REMOVAL INSTRUCTIONS.

To remove the alarm from the trim ring, rotate the alarm counter clockwise in
the direction of the "OFF" arrow on the cover. To disconnect the AC power,
squeeze the locking arms on the sides of the AC Quick Connector while pulling
the connector away from the bottom of the alarm (see Section 3, Figure 3).

ALARM REPLACEMENT

Ten years after initial power-up, this unit will “chirp” every 30 seconds to indi-
cate that it is time to replace the alarm. A label has been provided on the side
of the alarm that has “Replace by” printed on it. Write the replace by date on
the label.  The date written on the label should be after ten (10) years of cumu-
lative power. NOTE: Chirping once a minute is an indication of a low battery
where as the indication for replacement is once every 30 seconds.

BATTERY INSTALLATION AND REMOVAL

Battery Replacement

If any form of battery failure is detected, the red LED light will flash and the unit
will “chirp” once every minute.

Refer to Section 3, BATTERY INSTALLATION and the inside of the battery
door. 

USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR SMOKE ALARM REPLACE-
MENT.

 

Summary of Contents for RF-SM-ACDC

Page 1: ...fire by linking alarms so that when one unit sounds it will trigger all other units to sound thereby giving a family more time to escape Kidde estimates that nearly 100 million U S homes either do not...

Page 2: ...Wireless AC Powered Smoke Alarm Never connect two as doing so will result in the wireless alarms triggering each other They will not stop alarming until one is disconnected from the electrical circuit...

Page 3: ...IDE NEAR THE ALARM FOR FUTURE REFERENCE This alarm is interconnect compatible with the following alarms and accessories Smoke alarms 1235 1275 1276 1285 1296 i12020 i12040 i12060 i12080 PE120 PI2000 K...

Page 4: ...alarm in the center of the ceiling places it clos est to all points in the room Ceiling mounting is preferred in ordinary resi dential construction For mobile home installation select locations carefu...

Page 5: ...the top edge of the alarm at a minimum of 4 10 cm and a maximum of 12 30 5 cm below the ceiling see Figure 1 If you are not sure about the insulation in your mobile home or if you notice that the oute...

Page 6: ...devices known to transmit in the RF band Electronic noise may cause nuisance alarms Near large metal surfaces and bundles of wire Smoke alarms are not to be used with detector guards unless the combin...

Page 7: ...Wireless smoke alarms enter alarm mode first check to see if there is a fire If a fire does not exist and the test buttons have not been activated on any of the units it is likely that you are receiv...

Page 8: ...d it is still possible to intercon nect up to a total of 6 remote signaling devices and or relay modules Kidde alarms and accessories CAN ONLY BE interconnected with other Kidde alarms and accessories...

Page 9: ...battery backup once the unit has been connected to AC power and mounted to the electrical box with the included trim ring See MOUNTING INSTRUCTIONS in the following section To install a battery for t...

Page 10: ...uses a 9V alkaline battery lithium batteries may also be used A fresh battery should last for one year under normal operating conditions This alarm has a low missing battery monitor circuit that will...

Page 11: ...ap into place Then push the excess wire back into the electrical box through the hole in the center of the mounting bracket 5 Install the alarm on the mounting bracket and rotate the alarm clockwise u...

Page 12: ...complete When the smoke alarm ionization chamber senses products of combustion the horn will sound a loud 85db temporal alarm until the sensing chamber is cleared of smoke particles Smart HUSH CONTRO...

Page 13: ...ace the battery at a more convenient time without sacrificing your safety by disconnecting the alarm from power During this Low Battery HUSH period your alarm is performing normally and is not desensi...

Page 14: ...rms to enter alarm mode in response to a remote push to test If the alarm does not sound check the fuse or circuit breaker supplying power to the alarm circuit If the alarm still does not sound the un...

Page 15: ...m ring rotate the alarm counter clockwise in the direction of the OFF arrow on the cover To disconnect the AC power squeeze the locking arms on the sides of the AC Quick Connector while pulling the co...

Page 16: ...all your alarm verify the green LED is on and test your alarm by using the test button If cleaning does not restore the alarm to normal operation the alarm should be replaced 7 LIMITATIONS OF SMOKE AL...

Page 17: ...on a different floor it may not wake up a sound sleeper The use of alcohol or drugs may also impair one s ability to hear the smoke alarm For maximum protection a smoke alarm should be installed in ea...

Page 18: ...nside door without first feeling its surface If hot or if you see smoke seeping through cracks don t open that door Instead use your alternate exit If the inside of the door is cool place your shoulde...

Page 19: ...rms For this reason it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dinin...

Page 20: ...rm is receiving AC power or that it blinks every ten seconds this tells you that it is receiving only battery power If not make sure the batteries are installed correctly and AC Quick Connector is ins...

Page 21: ...tional radiators The user is not permitted to make any modifications to this equipment or use it in any manner inconsistent with the methods described in this User s Guide without express approval fro...

Page 22: ...EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE OR ANY OF ITS PARENT OR SUB SIDIARY CORPORATIONS BE LIABLE FOR CONSEQUENTIAL LOSS OR DAMAGES RESULTING FROM THE FAILURE OF THE...

Reviews: