background image

Operation

13

Testing

Test by pushing the Test button on the cover and hold it
down for a minimum of 5 seconds. This will sound the
alarm if all the electronic circuitry, horn and battery are
working. If no alarm sounds, the unit has defective
batteries or other failure. DO NOT use an open flame to
test your alarm, you could damage the alarm or ignite
combustible materials and start a structure fire.

Test the alarm weekly to ensure proper operation.

Erratic or

low sound coming from your alarm may indicate a defective
alarm, and it should be returned to place of purchase (see

Warranty

section).

NOTE: WEEKLY TESTING IS REQUIRED!

Alarm Removal

If the smoke alarm tamper resist feature has been activated, refer
to the alarm tamper-resist feature section for removal instructions.
To remove the alarm from the mounting plate, rotate the alarm
in the direction of the "OFF" arrow on the cover.

Battery Replacement

This smoke alarm uses a 9 V alkaline battery (a lithium battery
may also be used). A fresh alkaline battery should last for one
year under normal operating conditions. This alarm has a low
battery monitor circuit which will cause the alarm to “chirp”
approximately every 30 seconds for a minimum of 7 days when
the battery loses power. Replace when this condition occurs.
Continued “chirping” after the battery replacement may indicate
defective circuitry, and the alarm should be returned to place
of purchase.

Use only the following 9 V batteries for replacement:

Alkaline Type

Energizer  522
Duracell MN1604 or MX1604
Gold Peak 1604A
Panasonic 6AM6, 6AM-6, 6AM-6PI,
6AM6X, and 6LR61(GA)

Lithium Type

Ultralife  U9VL-J

Maintenance

Summary of Contents for PI9000CA

Page 1: ...tect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires s...

Page 2: ...ly are at stake Please take a few minutes to thoroughly read this alarm manual and save it for future reference Teach children how to respond to the alarms and that they should never play with the uni...

Page 3: ...32 27 The purchaser is exempt from any regulatory requirements This smoke alarm uses an extremely small amount of radioactive element in the ionization sensor chamber Do not try to repair the smoke a...

Page 4: ...n alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the roo...

Page 5: ...f the peak of the ceiling measured horizontally Image 2B and Image 2C 4 Installation DINING ROOM LIVING ROOM Smoke Alarms for Minimum Protection Ionization Type Smoke Alarm with Hush Control or Photoe...

Page 6: ...excessively dusty dirty or greasy areas Dust particles may cause nuisance alarms or failure to alarm Extreme temperatures may effect the sensitivity of the alarm Do not install in areas where the temp...

Page 7: ...OM PEAK CEILING 10 cm 4 MINIMUM 10 cm 4 MINIMUM 30 5 cm 12 MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT NEVER HERE S T A G N A N T A I R 10 cm 4 0 9 m 3 0 9 m 3 NOT IN THIS AREA ANYWHERE IN T...

Page 8: ...e either hot or cold install the alarm on an inside wall For minimum protection install at least one alarm close to the bedrooms For additional protection see Image 1A WARNING Test your smoke alarm op...

Page 9: ...he cover until the alarm ratchets into place Image 3D This ratcheting function allows for aesthetic alignment Note The alarm will attach to the mounting plate in 4 positions every 90 A A IMAGE 3A IMAG...

Page 10: ...battery the battery door will not close and the unit will not attach to the mounting plate Testing After installation test your alarm by depressing and holding down the test button for 5 seconds unti...

Page 11: ...the alarm does sound check for fires first If a fire is discovered get out and call the fire department If no fire is present check to see if one of the reasons listed in Locations to Avoid may have...

Page 12: ...ate the tamper resist feature by breaking off the four posts in the square holes in the mounting plate see Image 5A Rotate the alarm onto the mounting plate until you hear the tamper resist tab snap i...

Page 13: ...ery Condition The red LED will be accompanied by an audible chirp Replace the battery when this condition occurs Alarm Memory This smoke alarm is equipped with an alarm memory feature which produces a...

Page 14: ...he alarm tamper resist feature section for removal instructions To remove the alarm from the mounting plate rotate the alarm in the direction of the OFF arrow on the cover Battery Replacement This smo...

Page 15: ...e alarm should be cleaned at least once a year To clean your alarm remove it from the mounting plate as outlined in previous sections You can clean the alarm by using compressed air or a vacuum cleane...

Page 16: ...g limitations Ionization sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire par...

Page 17: ...e routes from each room Second story windows may need an escape ladder Have a family meeting and discuss your escape plan showing everyone what to do in case of fire Determine a place outside your hom...

Page 18: ...e and make sure everyone is there Call the fire department from your neighbor s home not from yours Don t return to your home until the fire officials say that it is all right to do so There are situa...

Page 19: ...n for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the householder consider the use of additional smoke alarms for those...

Page 20: ...abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power The liability of Kidde or any of its parent or subsidiary cor...

Reviews: