Wiring Instructions

CAUTION! Turn off the main power to the circuit before wiring
the alarm.

• For alarms that are used as single station, DO NOT CONNECT

THE RED WIRE TO ANYTHING. Leave the red wire insulating
cap in place to make certain that the red wire cannot contact
any metal parts or the electrical box.

• When alarms are interconnected, all interconnected units must

be powered from a single circuit.

• A maximum of 24 Kidde devices may be interconnected in a

multiple station arrangement. The interconnect system should
not exceed the NFPA interconnect limit of 12 smoke alarms
and/or 18 alarms total (smoke, heat, carbon monoxide, etc.)
With 18 alarms interconnected, it is still possible to interconnect
up to a total of 6 remote signaling devices and/or relay modules.

CAUTION! 

Kidde alarm and accessories CAN ONLY BE

interconnected with other Kidde alarms and accessories as well
as specified brands and models of interconnect compatible alarms.
Connection of Kidde products to a non-specified manufacturer’s
interconnect system, or connection with non-specified equipment
from another manufacturer into an existing Kidde system could
result in nuisance alarming, failure to alarm, or damage to one
or all of the devices in the interconnect system. Refer to the
User’s Guide supplied with each Kidde product for interconnect
compatible models, brands, and devices.

• When mixing models which have battery backup with models

without battery backup, be advised that the models without
battery backup will not respond during an AC power failure.

• The maximum wire run distance between the first and last

unit in an interconnected system is 305 m (1000').

• Image 3 illustrates interconnection wiring. Improper connection

will result in damage to the alarm, failure to operate, or a
shock hazard.

• Make certain alarms are wired to a continuous (non-switched)

power line. NOTE: Use standard CSA listed household wire
(as required by local codes) available at all electrical supply
stores and most hardware stores.

Installation

8

Summary of Contents for PI2000CA

Page 1: ...sensing alarms may detect invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with s...

Page 2: ...y are at stake Please take a few minutes to thoroughly read this alarm manual and save it for future reference Teach children how to respond to the alarms and that they should never play with the unit...

Page 3: ...duct is designed to detect products of combustion using both an ionization sensor and a photoelectric sensor The ionization sensor contains 0 9 microcurie of Americium 241 a radioactive material Distr...

Page 4: ...n alarm not located in that room from waking the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the centre of the roo...

Page 5: ...3 of the peak of the ceiling measured horizontally Image 2B and Image 2C 4 Installation DINING ROOM LIVING ROOM Smoke Alarms for Minimum Protection Ionization Type Smoke Alarm with Hush or Photoelect...

Page 6: ...essively dusty dirty or greasy areas Dust particles may cause nuisance alarms or failure to alarm Extreme temperatures may effect the sensitivity of the alarm Do not install in areas where the tempera...

Page 7: ...OM PEAK CEILING 10 cm 4 MINIMUM 10 cm 4 MINIMUM 30 5 cm 12 MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT NEVER HERE S T A G N A N T A I R 10 cm 4 0 9 m 3 0 9 m 3 NOT IN THIS AREA ANYWHERE IN T...

Page 8: ...ile home vehicle has been in storage before each trip and at least once a week during use Wiring Requirements This smoke alarm should be installed on a CSA listed or recognized junction box All connec...

Page 9: ...nd models of interconnect compatible alarms Connection of Kidde products to a non specified manufacturer s interconnect system or connection with non specified equipment from another manufacturer into...

Page 10: ...Alarm Additional Alarm Kidde Relay Module SM120X Additional Alarm Optional Accessory WIRES ON ALARM HARNESS Black Connected to hot side of AC line White Connected to neutral side of AC line Red Conne...

Page 11: ...irection indicated by the OFF arrow on the alarm cover After selecting the proper smoke alarm location as described previously and wiring the AC Quick Connect wire harness as described in Wiring Instr...

Page 12: ...place Then push the excess wire back into the electrical box through the hole in the center of the mounting plate Install the alarm on the mounting plate and rotate the alarm in the direction of the...

Page 13: ...battery the battery door will not close and the unit will not attach to the mounting plate Testing After installation test your alarm by depressing and holding down the test button for 5 seconds or un...

Page 14: ...If the alarm does sound check for fires first If a fire is discovered get out and call the fire department If no fire is present check to see if one of the reasons listed in Locations to Avoid may hav...

Page 15: ...ate the tamper resist feature by breaking off the four posts in the square holes in the mounting plate see Image 7A Rotate the alarm onto the mounting plate until you hear the tamper resist tab snap i...

Page 16: ...ntinue until the air is cleared Hush Condition The red LED will flash every 2 seconds as long as the alarm is in Hush mode Low Battery Condition The red LED flash will be accompanied by an audible chi...

Page 17: ...of the interconnected alarms is pressed If no alarm sounds the unit has defective batteries or other failure DO NOT use an open flame to test your alarm you could damage the alarm or ignite combustibl...

Page 18: ...you can open the battery door and install or replace the battery Battery installation instructions are provided on the inside of the battery door This smoke alarm uses a 9 V alkaline battery a lithiu...

Page 19: ...o clean your alarm remove it from the mounting plate as outlined in previous sections You can clean the alarm by using compressed air or a vacuum cleaner hose with a soft brush attachment Blow or vacu...

Page 20: ...ct invisible fire particles associated with fast flaming fires sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smouldering fires so...

Page 21: ...an meet if a fire occurs Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it Practice a fire drill at least every six months including fire drill...

Page 22: ...e and make sure everyone is there Call the fire department from your neighbor s home not from yours Don t return to your home until the fire officials say that it is all right to do so There are situa...

Page 23: ...ber of smoke alarms as shown in Image 1A and Image 1B The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protect...

Page 24: ...modified abused or altered after the date of purchase or if it fails to operate due to improper maintenance or inadequate AC or DC electrical power The liability of Kidde or any of its parent or subsi...

Reviews: