This feature is to be used only when a known alarm condition, such as smoke 
from cooking, activates the alarm. The smoke alarm is desensitized by pushing 
the Test/Hush button on the smoke alarm cover. If the smoke is not too dense, 
the alarm will silence immediately and the red LED blinks every 10 seconds. This 
indicates that the alarm is in a temporarily desensitized condition. 

The smoke alarm will automatically reset within 10 minutes and sound the alarm 
if particles of combustion are still present. 

The SMART HUSH

TM

 feature can be used repeatedly until the air has been 

cleared of the condition causing the alarm. Pushing the Test/Hush button on the 
alarm will end the temporarily desensitized period. 

If the smoke is not too dense, within 10 minutes the alarm will return to normal 
operation.

NOTE: Dense smoke will override the SMART HUSH

TM

 feature and  

sound a continuous alarm. 
       CAUTION: Before using the alarm SMART HUSH

TM

 feature, identify  

the source of the smoke and be certain safe conditions exist.

8. BATTERY

NOTE: One lithium battery, permanently sealed inside the alarm, powers this 
unit; no battery installation or replacement is necessary for the life of the alarm.

IMPORTANT:

 Constant exposure to high or low humidity may reduce battery life.

 WARNING! DO NOT ATTEMPT TO OPEN THE ALARM  

FOR ANY REASON!

Do not try to repair the smoke alarm yourself. No serviceable parts included.

Low battery:

 This alarm is equipped with a low battery monitor circuit which 

will cause the alarm to produce a single “chirp” approximately every 60  
seconds and blink the Red LED every 30 seconds, for a minimum of seven  
(7) days should the battery become low. 

The unit must be replaced within 7 days of the first occurrence of the 
“Low Battery Warning” to provide continuous alarm protection. THE 
UNIT MUST BE DISCHARGED (see “Permanently Disable Alarm / Discharge 
Battery” section) when alarm is in “low battery” condition.

Summary of Contents for P3010K-CO

Page 1: ...monoxide from any source of combustion in a residential environ ment It is not designed for use in a recreational vehicle RV or boat P N P N 2534 7221 01 RevA For your convenience write down the follo...

Page 2: ...pen that door Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in Stay close to the...

Page 3: ...d appliance technician to investigate sources of CO from fuel burning equipment and appliances and to inspect for proper operation of equipment If problems are identified during this inspection have t...

Page 4: ...applications where a smoke or CO alarm is required After ten 10 years of cumulative power up this unit will chirp two times every 30 seconds This is an operational end of life feature which will indi...

Page 5: ...sooner than photoelectric alarms Photoelectric sensing alarms may detect visible fire particles associated with slow smoldering fires sooner than ion ization alarms Home fires develop in different wa...

Page 6: ...as defined in the National Electric Code It is not designed for use in a recreational vehicle RV or boat The installation of this device should not be used as a substitute for proper installation use...

Page 7: ...alarm in every bedroom Locate an alarm in every room where electrical appliances are operated i e portable heaters or humidifiers Locate an alarm in every room where someone sleeps with the door close...

Page 8: ...OBILE HOME INSTALLATION Modern mobile homes have been designed and built to be energy efficient Install smoke alarms as recommended above In older mobile homes that are not well insulated compared to...

Page 9: ...rm or failure to alarm In very humid areas Moisture or steam can cause nuisance alarms In insect infested areas Smoke alarms should not be installed within 3 ft 9m of the door to a bathroom containing...

Page 10: ...n Section 2 attach the mounting bracket to the ceiling as shown in Image 4 For wall mounting see Image 5 Place the mounting plate on the wall be sure the A line is horizontal parallel to the floor Use...

Page 11: ...icks into place If unit needs to be re aligned rotate the alarm counter clockwise remove and rotate to desired alignment NOTE The alarm will mount to the plate in three 3 positions every 120 degrees Y...

Page 12: ...D light The CO sensor meets the alarm response time as follows At 70 PPM the unit must alarm within 60 240 minutes At 150 PPM the unit must alarm within 10 50 minutes At 400 PPM the unit must alarm wi...

Page 13: ...tact Product Support at 1 800 880 6788 or write us at Kidde 1016 Corporate Park Drive Mebane NC 27302 Our internet address is www kidde com End of life hush feature Silences end of life indication 3 d...

Page 14: ...feature and sound a continuous alarm CAUTION Before using the alarm SMART HUSHTM feature identify the source of the smoke and be certain safe conditions exist 8 BATTERY NOTE One lithium battery perman...

Page 15: ...LARM DISCHARGE BATTERY WARNING Failure to discharge alarm as instructed prior to disposal may create potential for lithium battery related fire or hazard After the tab is broken use the screwdriver to...

Page 16: ...n transient CO situations Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as Wind direction and or velocity including high gusts of wind heav...

Page 17: ...scussed with ALL members of the household 1 Mild Exposure Slight headache nausea vomiting fatigue often described as Flu like symptoms 2 Medium Exposure Severe throbbing headache drowsiness confusion...

Page 18: ...d may cause false read ings and damage to the sensor Methane propane isobutane iso propanol ethyl acetate hydrogen sulfide sulfide dioxides alcohol based products paints thinner solvents adhesives hai...

Page 19: ...test your plan before an emergency You may not be able to reach your children It is important they know what to do Familiarize everyone with the sound of the smoke CO alarm and train them to leave yo...

Page 20: ...might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms For this reason it is recommended that the house holder co...

Page 21: ...e include your name address and phone number along with a brief description of what is wrong with the unit For further assistance please call our toll free Customer Service at 1 800 880 6788 Damage fr...

Page 22: ...indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach of contract negligence strict liability in...

Reviews: