Interconnect Feature

Your Combination Smoke/CO Alarm is interconnectable to other

multiple station Kidde, Nighthawk and Kidde/Fyrnetics products:
• When compatible smoke alarms and heat alarms are

interconnected to your Smoke/CO Alarm, they will only
respond to a smoke related event.

• When mixing compatible models with battery backup with models

without battery backup, be advised that the models without battery

backup will not respond during an AC power failure.

• This unit is only approved to interconnect with other

Kidde/Nighthawk products. It is NOT approved to interconnect
with any other brand of detection product.

• This alarm is interconnect compatible with the following alarms

and accessories:

–Smoke alarms: 1235, 1275, 1276, 1285, i12020, i12020A,

i12040, i12040A, i12060, i12060A, i12010SCO, i12010S,
i4618, i4618A, KN-SMFM-I, RF-SM-ACDC, PE120, P12040,
Pi2000, Pi2010, i12080, i12080A, KN-COSM-I, KN-COSM-
IB, KN-COSM-IBA

– Heat alarm: HD135F
– CO alarms: KN-COB-IC, KN-COP-IC, KN-COPE-I
– Relay modules: SM120X, CO120X
– Strobe Light: SL177i, SLED177i

• For more information about compatible interconnect units and

their functionality in an interconnect system, visit our web site
at www.kidde.com.

Smoke HUSH Control Feature

The HUSH feature has the capability of temporarily desensitizing
the smoke alarm circuit for approximately 9 minutes. This feature
is to be used only when a known alarm condition, such as smoke
from cooking, activates the alarm. When the unit is in alarm,You
can put your Smoke/CO Alarm in HUSH mode by pushing the
test/reset button. If the smoke is not too dense, the alarm will
silence immediately, the unit will verbally announce “HUSH
MODE ACTIVATED”, and the green LED will flash every 2 seconds
for approximately 9 minutes. This indicates that the smoke alarm
is in a temporarily desensitized condition. Your Smoke/CO Alarm
will automatically reset after approximately 9 minutes. When the
unit returns to normal operation after being in HUSH mode, it
will verbally announce “HUSH MODE CANCELLED”, and sound
the alarm if smoke is still present. The HUSH feature can be used
repeatedly until the air has been cleared of the condition causing
the alarm. While the unit is in HUSH mode, pushing the test/reset
button on the alarm will also end the HUSH period.

15

Operating Instructions

2550-7201-01(i12010SCO)_V4.qxd:_  2014.2.20  10:24 AM  Page 17

Summary of Contents for i12010SCO

Page 1: ...MONOXIDE ALARM GREEN STANDBY For your convenience write down the following information If you call our Product Support Line these are the first questions you will be asked Alarm Model Number located o...

Page 2: ...at to do if the Alarm Sounds Smoke Alarm Pages 18 19 Carbon Monoxide Alarm Pages 20 Alarm Removal Battery Pages 21 22 End of Product Life Notification Page 21 DEACTIVATION OF ALARM Page 22 General Ala...

Page 3: ...the alarms and that they should never play with the unit Your Kidde Smoke CO Alarm was designed to detect both smoke and carbon monoxide from any source of combustion in a residential environment It...

Page 4: ...Product View FRONT 2 ALARM SOUNDER RED AND GREEN LED VOICE SPEAKER 10 YEAR SMOKE AND CARBON MONOXIDE ALARM GREEN STANDBY...

Page 5: ...Product View BACK 3 D...

Page 6: ...ern is four short alarm beeps followed by the verbal warning message WARNING CARBON MONOXIDE This continues until the unit is reset or the CO is eliminated While powered by battery only after four min...

Page 7: ...lence the end of life chirp for approximately 3 days at a time for a maximum of 30 days life extension One chirp every 30 seconds coupled with a green LED flash twice a second is an indication that th...

Page 8: ...or these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are devices that can provide early warning of possible fires at a reasonable cost h...

Page 9: ...de CO alarm monitors the air for the presence of CO It will alarm when there are high levels of CO present and when there are low levels of CO present over a longer period of time see page 21 for alar...

Page 10: ...the main sleeping area or in the main bedroom Verify the alarm can be heard in all sleeping areas Locate an alarm in every room where someone sleeps with the door closed The closed door may prevent a...

Page 11: ...rms shall be spaced and located within 3 ft 0 9 m of the peak of the ceiling measured horizontally see figure 2 Install Smoke Alarms on tray shaped ceilings coffered ceilings on the highest portion of...

Page 12: ...es kitchens furnace rooms or bathrooms INSTALL AT LEAST 5 FEET AWAY FROM ANY FUEL BURNING APPLIANCE Do not install within 3 ft 9m of the following The door to a kitchen or a bathroom that contains a t...

Page 13: ...3 B of the U S National Electrical Code ANSI NFPA 70 NFPA 72 and or any other codes having jurisdiction in your area The multiple station interconnect wiring to the alarms must be run in the same rac...

Page 14: ...ination heat etc This Smoke CO combination alarm must be counted as a smoke alarm when determining the number of units on an interconnect line With 18 alarms interconnected it is still possible to int...

Page 15: ...in the direction indicated by the OFF arrow on the alarm cover 3 After selecting the proper location for your Smoke CO Alarm as described on Pages 8 10 and wiring the AC QUICK CONNECT harness as descr...

Page 16: ...emergency service provider Fire Department or 911 in the space provided Place one label next to the alarm after it is mounted and one label near a fresh air source such as a door or window Step 4 Tes...

Page 17: ...ormation about compatible interconnect units and their functionality in an interconnect system visit our web site at www kidde com Smoke HUSH Control Feature The HUSH feature has the capability of tem...

Page 18: ...k Level Memory press the test reset button If a reading of 100 PPM or higher has been recorded the unit will announce Carbon Monoxide Previously Detected If you ve been away from home this feature all...

Page 19: ...unit is initiating the alarm Trouble Fault Error mode 1 2 second flash rate AC powered only Helps owner locate the mysterious chirping unit HUSH MODE Condition The LED will flash every 2 seconds while...

Page 20: ...arm sounds Smoke alarms are designed to minimize false alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm Combustion particles from cooking ma...

Page 21: ...any circumstance until fire officials give the go ahead There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA Standard 72 For instance a smoking...

Page 22: ...1 3 and call a qualified appliance technician to investigate for sources of CO from fuel burning equipment and appliances and inspect for proper operation of this equipment If problems are identified...

Page 23: ...D D s se ee e D De ea ac ct ti iv va at ti io on n o of f A Al la ar rm m s se ec ct ti io on n a an nd d r re ep pl la ac ce ed d w wi it th hi in n 7 7 d da ay ys s o of f t th he e f fi ir rs st t...

Page 24: ...been deactivated it cannot be mounted onto the mounting plate or reactivated WARNING Failure to turn off alarm as instructed prior to disposal may create potential for lithium battery related fire or...

Page 25: ...ion will void your warranty Move the Smoke CO Alarm and place in another location prior to performing any of the following Staining or stripping wood floors or furniture Painting Wall papering Using a...

Page 26: ...ources of CO The following conditions can result in transient CO situations Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as Wind direction...

Page 27: ...experienced seek medical attention immediately CO poisoning can be determined by a carboxyhemoglobin test The following symptoms are related to CARBON MONOXIDE POISONING and should be discussed with...

Page 28: ...a rule that once you re out you never reenter under any circumstance Current studies have shown smoke alarms may not awaken all sleeping individuals and that it is the responsibility of individuals i...

Page 29: ...mended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room furnace room utility roo...

Page 30: ...ection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Page 31: ...cular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or consequential...

Page 32: ...Warranty Returns 1016 Corporate Park Dr Mebane NC 27302 USA Please include your name address and phone number along with a brief description of what is wrong with the unit For further assistance pleas...

Page 33: ...MORE INFORMATION Call our Product Support Line at 1 800 880 6788 or contact us at our website at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302 Custom Assembled in China with U S and Fo...

Reviews: