4. OPERATION AND TESTING

OPERATION:

The smoke alarm is operating once the alarm is 

activated (see Section 3) and testing is complete.  When products
of combustion are sensed, the unit sounds a loud 85db pulsating
alarm until the air is cleared.

SMART HUSH

®

CONTROL: The SMART HUSH

®

feature has the

capability of temporarily desensitizing the alarm circuit for 
approximately 8 minutes.  This feature is to be used only when a
known alarm condition, such as smoke from cooking, activates the
alarm.  The smoke alarm is desensitized by pushing the button on
the smoke alarm cover.  If the smoke is not too dense, the alarm
will silence immediately and the red LED will illuminate for 1 sec-
onds every 8 seconds for 7 to 9 minutes.  This indicates that the
alarm is in a temporarily desensitized condition.  The smoke alarm
will automatically reset after approximately 8 minutes and sound
the alarm if particles of combustion are still present.  The SMART
HUSH

®

feature can be used repeatedly until the air has been

cleared of the condition causing the alarm. Pushing the button on
the alarm will end the temporarily desensitized period.

NOTE: DENSE SMOKE WILL OVERRIDE THE SMART HUSH

®

CONTROL FEATURE AND SOUND A CONTINUOUS ALARM.

CAUTION: BEFORE USING THE ALARM SMART HUSH

®

FEATURE, IDENTIFY THE SOURCE OF THE SMOKE AND BE
CERTAIN A SAFE CONDITION EXISTS.

FLASHING LED LIGHT:

This smoke alarm is equipped with a 

flashing red indicator light with four modes of operation:

• The LED will flash every 40-45 seconds in the standby mode 

signifying that the alarm is receiving power.

• The LED will flash every 1.5 seconds when the alarm is sound-

ing.

• The LED will illuminate for 1 seconds every 8 seconds while the

alarm is in the temporarily desensitized mode.

• If alarm memory has been set (see below for alarm memory

description), the LED will flash rapidly when the button is
pressed.

!

0920-7201-00_EN_V10.qxd:_  2017.4.27  10:02 AM  Page 7

Summary of Contents for i1040

Page 1: ...t is an important part of your family s home safety plan You can trust this product to provide the highest quality safety protection We know you expect nothing less when the lives of your family are a...

Page 2: ...E BATTERY 8 MAINTENANCE 9 LIMITATIONS OF SMOKE ALARMS 10 GOOD SAFETY HABITS 11 NRC INFORMATION 12 NFPA REQUIRED PROTECTION 13 CALIFORNIA STATE FIRE MARSHAL REQUIRED INFORMATION 14 FCC 15 SERVICE AND W...

Page 3: ...rom the side wall see figure 1 When mounting the alarm on the wall use an inside wall with the top edge of the alarm at a minimum of 4 10 cm and a maximum of 12 30 5 cm below the ceiling see figure 1...

Page 4: ...inimum of 4 10 cm and a maximum of 12 30 5 cm below the ceiling see figure 1 If you are not sure about the insulation in your mobile home or if you notice that the outer walls and ceiling are either h...

Page 5: ...less the combination alarm and guard has been evaluated and found suitable for that purpose 3 INSTALLATION INSTRUCTIONS CAUTION THIS UNIT IS SEALED INCLUDING THE BATTERY THE COVER IS NOT REMOVABLE REM...

Page 6: ...ion is a one time action and cannot be reversed Once activated the battery will supply power to the alarm for the life of the alarm 10 years Be sure that the mounting bracket is mounted correctly befo...

Page 7: ...minutes and sound the alarm if particles of combustion are still present The SMART HUSH feature can be used repeatedly until the air has been cleared of the condition causing the alarm Pushing the bu...

Page 8: ...for service see Section 15 5 NUISANCE ALARMS Smoke alarms are designed to minimize nuisance alarms Cigarette smoke will not normally set off the alarm unless the smoke is blown directly into the alarm...

Page 9: ...in the direction of the arrows on the cover see ACTIVATING ALARM in Section 3 INSTALLATION INSTRUCTIONS Low battery This alarm has a battery monitor circuit which will cause the alarm to chirp every 4...

Page 10: ...ted WARNING Failure to DISCHARGE alarm as instructed prior to disposal may create potential for lithium battery related fire or hazard To Permanently Disable Alarm Discharge Battery Push in the dashed...

Page 11: ...ons by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupants in potentially fatal fires Victims are often intimate with the fire too old or youn...

Page 12: ...D SAFETY HABITS DEVELOP AND PRACTICE A PLAN OF ESCAPE Install and maintain Fire extinguishers on every level of the home and in the kitchen basement and garage Know how to use a fire extinguisher prio...

Page 13: ...cracks don t open that door Instead use your alternate exit If the inside of the door is cool place your shoulder against it open it slightly and be ready to slam it shut if heat and smoke rush in Sta...

Page 14: ...on Where required by other governing laws codes or standards for a specific type of occupancy approved single and multiple station smoke alarms shall be installed as follows 1 In all sleeping rooms an...

Page 15: ...larm installed in each separate sleeping area in the vicinity of but outside of the bedrooms and heat or smoke detectors in the living rooms dining rooms bedrooms kitchens hallways attics furnace room...

Page 16: ...PO RATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO CASE SHALL KIDDE SAFETY O...

Reviews: