Kidde FENWAL 35-71 Series Manual Download Page 7

Series 35-71, 120 VAC Direct Spark Ignition Control

Page 7

www.fenwalcontrols.com

1-800-FENWAL-1

1

. SILICONE RUBBER SUPRESSION TYPE: 

Resistive carbon coated fiberglas core prevents spark energy radiation from interfering with

other electronic systems.  Select this wire type for applications where wire lengths are less than 36” and noise is a major concern.

SPECIFICATIONS:

Voltage Rating

Agency Rating

Temperature Rating

Diameter

Jacket Material

25 KVDC

SAE J2031

200°C (392°F) 

7mm (.27”)

Silicone Rubber

over Fiberglas Braid

Part Number: 05-129608-0XX

Part Number: 05-129608-2XX

Part Number: 05-129608-6XX

1/4” FEMALE Q.C. WITH SILICONE RUBBER BOOT

RIGHT ANGLE SPARK PLUG
WITH SILICONE RUBBER BOOT 

High Voltage Ignition Wire - 3 Types

Part Number: 05-127613-2XX

Part Number: 05-129865-0XX

Part Number: 05-125948-0XX

Part Number: 05-129867-0XX

Delivering the 15K to 25K volts of spark energy from the ignition control to the electrode is a vital element of an ignition system.  
There are 3 material options and multiple terminal configurations available.  Shown are the most popular versions offered by Fenwal. 
To ensure maximum spark energy, it is recommended that the ignition wires not be longer than 36”.  Longer lengths are available 
and should be evaluated on the appliance to determine if there is sufficient spark energy to consistently light the burner under 
all conditions.  Once the wire type and terminal configurations are determined, complete the part number by replacing the last two 
digits (“XX”) with the length in inches (“L” dimension).  Standard wire lengths are 12, 18, 24, 30, 36, 48 and 60 inches.  
Example: 05-129608-018 = 18 inches.  For other lengths, please contact Fenwal.

1/4” FEMALE Q.C.  -
FULLY INSULATED
BOTH ENDS

1/4” FEMALE Q.C. 
BOTH ENDS

RIGHT ANGLE SPARK PLUG WITH
SILICONE RUBBER BOOT

1/4” FEMALE Q.C. 

TERMINATIONS SAME AS TYPE 1

Part Number: 05-129866-0XX

Part Number: 05-129866-1XX

3/16”FEMALE Q.C.
FULLY INSULATED

1/4”FEMALE Q.C.
FULLY INSULATED

1/4” FEMALE Q.C. FULLY INSULATED

BOTH ENDS

2

. SILICONE RUBBER COPPER CONDUCTOR TYPE:

Low resistance copper conductor transmits maximum spark energy.  Select this

type when maximum energy or longer wire lengths are required and noise is not a major concern.

SPECIFICATIONS: Voltage Rating

Agency Rating

Temperature Rating

Diameter

Jacket Material

25 KVDC  

UL Type 3257  

250

°

C (482

°

F) 

7mm (.27”)

Silicone Rubber

3

. TEFLON INSULATED TYPE: 

Low resistance copper conductor transmits maximum spark energy.  Select this type 

for applications that have tight clearances and sharp bend radii.

SPECIFICATIONS:

Voltage Rating

Agency Rating

Temperature Rating

Diameter

Jacket Material

25 KVDC

UL Type 1911

250

°

C (482

°

F)

2mm (.08”) 

Teflon

4

. FLAME SENSE WIRES: 

Spark electrodes with integral remote sense rod, i.e. 22-100001-076, have a 3/16” male q.c..  

Please choose flame sense wire 05-129866-0XX.  For remote flame sense rods , i.e. 22-100001-080, choose flame sense 
wire part number 05-129866-1XX.

SPECIFICATIONS: Voltage Rating

Agency Rating

Temperature Rating

Diameter

Jacket Material

600  V

UL/CSA Listed

200°C (392°F)

18 gage stranded

PVC

Summary of Contents for FENWAL 35-71 Series

Page 1: ...main burner flame to ensure safe system operation The on board diagnostics with LED output provide assistance with troubleshooting to ensure safe and efficient burner operation Agency Certifications R...

Page 2: ...resumes If the burner fails to light after the third try the control will de energize the gas valve and go into lockout mode NOTE The Recycle feature option requires a special part number that is det...

Page 3: ...to 175 F 40 C to 80 C 120 VAC 1 0 microamp minimum 0 8 seconds maximum Natural LP and manufactured Line frequency 50 60 Hz Conformal coated to operate to 95 R H See drawings on Page 8 Integral stand o...

Page 4: ...on relies on the current passing from ground through the flame to the sense rod The minimum flame current necessary to keep the system operating is 1 0 microamperes SINGLE SPARK AND SENSE Figure 3a RE...

Page 5: ...se electrodes are designed for on site customization Cut and bend these to fit your application and then send the formed electrode back for Fenwal to detail or send us a print and we will provide you...

Page 6: ...anded PVC Gray Only 600 V UL CSA Listed 200 C 392 F 18 gage stranded PVC Electrode Assemblies continued REMOTE SENSE Part Number 05 129864 7XX Part Number 05 129864 8XX Part Number 22 100001 080 Part...

Page 7: ...determined complete the part number by replacing the last two digits XX with the length in inches L dimension Standard wire lengths are 12 18 24 30 36 48 and 60 inches Example 05 129608 018 18 inches...

Page 8: ...sense Thermostat power off reset 6 3 try remote sense Thermostat power off reset 7 3 try single spark and sense Automatic reset 8 3 try remote sense Automatic reset X X X 35 71 5 X X X 400 MAIN STREE...

Reviews: