background image

Mounting

Your CO alarm is designed for
mounting onto the inside wall.

You should fix the back plate
provided to the wall first, using
the screws and rawl plugs.

When the plate is attached
locate the the slots on the 
back of the alarm with the keys on the 
back plate, sliding downwards and into position until the
tab clips onto the top of the alarm (see figure 1).

To remove, press the tab against the wall and lift the alarm out of the
mounting plate.

Install your CO alarm 1.5 metres from the floor.

NOTE: Your 9CO5 CO alarm is not designed for portability.

Where To Install Your Kidde CO Alarm

The following suggestions are intended to help you with the
placement and installation of your Kidde CO alarm.

• Place out of the reach of children. Under no circumstance 

should children be allowed to handle the CO alarm.

• Install in a bedroom or hallway located close to the sleeping

area. Take special care to verify the alarm can be heard in 
sleeping areas. 

• It is recommended that a CO alarm be installed on each

level of a multilevel home.

• Locate at least 2 metres away from all fuel burning 

appliances.

• Placing at eye level allows for optimum monitoring of the 

red and green indicator lights, or, as a guide, 1.5 metres 
from the floor.

5

Installation Instructions

Figure 1

Summary of Contents for 9CO5

Page 1: ...ment Pages 9 10 What To Do If The Alarm Sounds Page 11 12 Alarm Instructions Emergency Response Alarm Danger Levels Pages 13 14 Caring For Your Kidde Battery Powered CO Alarm Pages 15 16 Frequently As...

Page 2: ...ne is susceptible to the danger of CO but experts agree that unborn babies small children pregnant women old age pensioners and people with heart or respiratory problems are at the highest risk for se...

Page 3: ...and the red alarm light will flash After approximately 20 30 seconds the green light will flash indicating that the unit is operational Replace battery cover Your Kidde CO alarm is now operational 3 Q...

Page 4: ...nly one carbon monoxide alarm in your home install the alarm near bedrooms not in the cellar or boiler room 4 Installation Instructions Recommended Location Upper Levels of Home Cellar Levels of Home...

Page 5: ...esigned for portability Where To Install Your Kidde CO Alarm The following suggestions are intended to help you with the placement and installation of your Kidde CO alarm Place out of the reach of chi...

Page 6: ...EVER place the CO alarm flat on a table top or similar surface Be aware that certain conditions can result in transient CO situations such as 1 Excessive spillage or reverse venting of fuel burning ap...

Page 7: ...nding of which CO levels are dangerous Green Operate Indicator Light The green light flashing every 30 seconds indicates the unit is functioning properly see figure 3 The green light will flash before...

Page 8: ...red alarm light flashes This does not indicate that carbon monoxide is present Due to the loudness of the alarm we suggest you place your fingers over the sounder opening when testing your Kidde CO A...

Page 9: ...y failure the unit will start chirping an audible alarm every 30 seconds the green and red alarm light will flash The battery error warning will continue until new batteries are placed in the unit or...

Page 10: ...roperly dispose of them as recommended by the manufacturer see figure 4 3 Reinstall the new batteries being careful to seat the red battery warning flags in the recess of the battery well Also note th...

Page 11: ...itish Gas 3 Immediately move to fresh air outdoors or by an open door window Do a head count to check that all persons are accounted for Do not re enter the premises nor move away from the open door w...

Page 12: ...fuel enginer to examine and or turn off your gas oil fired appliances such as space heater boiler water heater cooker oven clothes dryer or other sources of combustion such as paraffin burning stove o...

Page 13: ...ses may require treatment in a hyperbaric chamber Remember young children and household pets may be the first effected If you have additional questions please call Kidde on 0800 917 0722 13 Alarm Dang...

Page 14: ...alth Safety Executive HSE 14 Alarm Danger Levels cont The maximum allowable concentration for continuous exposure for healthy adults in any 8 hour period according to HSE Slight headache fatigue dizzi...

Page 15: ...ated dust Instruct children never to play with the CO alarm Warn children of the dangers of carbon monoxide poisoning Never use detergents or other solvents to clean the CO alarm Avoid spraying air fr...

Page 16: ...proper location to assure continuous protection from carbon monoxide poisoning When household cleaning supplies or similar contaminants are used the area should be well ventilated The following subst...

Page 17: ...talled to meet current building code requirements Generally one CO alarm can be adequate for 111 48 to 139 35 square metres of living space The most important determination for the number of CO alarms...

Page 18: ...en LED every 30 seconds indicates proper operation Red LED with loud 85db alarm indicates presence of CO Battery Replacement Red and green LED flashes and the unit chirps every 30 seconds Replace the...

Page 19: ...PERING OR OTHER CAUSES NOT ARISING FROM DEFECTS IN MATERIAL OR WORKMANSHIP THIS WARRANTY EXTENDS TO THE ORIGINAL CONSUMER PURCHASER OF THE PRODUCT ONLY Warranty Disclaimers Any implied warranties aris...

Page 20: ...is not a substitute for property disability life or other insurance of any kind Appropriate insurance coverage is your responsibility Consult your insurance agent Kidde makes no warranty express or im...

Page 21: ...te of Purchase Where Purchased For questions concerning your Carbon Monoxide Alarm please call Kidde Safety Europe Limited on 01753 685148 or fax 01753 685096 Please have the following information rea...

Reviews: