background image

1. Information About Carbon Monoxide

General Carbon Monoxide Information

Carbon monoxide is a colourless, odourless and tasteless poison gas 
that can be fatal when inhaled. CO inhibits the blood’s capacity to carry 
oxygen.

Periodically review this alarm manual and discuss your CO alarm emer-
gency procedure with all the members of your family. Never ignore a CO 
alarm. A true alarm is an indication of potentially dangerous levels of 
CO. CO alarms are designed to alert you to the presence of CO before 
an emergency – before most people would experience symptoms of CO 
poisoning, giving you time to resolve the problem calmly.

Determine if anyone in the household is experiencing symptoms of CO 
poisoning. Many cases of reported CO poisoning indicate that while 
victims are aware they are not well, they become so disoriented they 
are unable to save themselves by either exiting the building or calling 
for assistance. Also, young children and household pets may be the first 
affected. You should take extra precautions to protect high-risk persons 
from CO exposure because they may experience ill effects from CO at 
levels that would not ordinarily affect a healthy adult.

Symptoms of CO Poisoning

The following common symptoms are related to CO poisoning and 
should be discussed with ALL members of the household. 

Mild Exposure:

Slight headache, nausea, vomiting, fatigue (often described as “flu-like” 
symptoms).

Medium Exposure:

Severe throbbing headache, drowsiness, confusion, fast heart rate.

Extreme Exposure:

Unconsciousness, convulsions, cardio-respiratory failure, death.

If you experience even mild symptoms of CO poisoning, consult your 
doctor immediately!

2535-7201-00_revD_V1.indd   5

2535-7201-00_revD_V1.indd   5

2011.12.26   9:35:55 AM

2011.12.26   9:35:55 AM

Summary of Contents for 8LLCO

Page 1: ...d for future reference and passed on to any subsequent owner Carbon Monoxide Alarm User s Guide Models 8LLCO and 8LLDCO with digital display Model 8LLCO Model 8LLDCO with Digital Display EN 50291 1 20...

Page 2: ...ocal Gas Safe Registered Engineer Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the test reset button will...

Page 3: ...ecause your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smoke alarm CO is an invisible odourless tasteless and non i...

Page 4: ...onditions If in doubt consult a medical practitioner Individuals with medical problems may consider using warning devices which provide audible and visual signals for carbon mon oxide concentrations u...

Page 5: ...re they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young children and household pets may be the first affe...

Page 6: ...nate the source of CO See What to do When the Alarm Sounds inside front cover IMPORTANT Model 8LLCO does not have a digital display and does not display carbon monoxide levels in PPM If the alarm soun...

Page 7: ...vent pipe designs which can amplify the above situations Extended operation of unvented fuel burning devices range oven fireplace etc Temperature inversions which can trap exhaust gases near the grou...

Page 8: ...imitations Like any other electronic device CO alarms are not fool proof CO alarms have a limited operational life You must test your CO alarm weekly because it could fail to operate at any time If yo...

Page 9: ...every 30 seconds to indicate that it is time to replace the alarm Replace the alarm immediately It will not detect CO in this condition To help identify the date to replace the alarm a label has been...

Page 10: ...ocations DINING KITCHEN BEDROOM BEDROOM BEDROOM LIVING ROOM Recommended Locations Temperature Operating Range 0 to 40 C Humidity Operating range Up to 90 non condensing Audible Alarm 85 dB at 1 metre...

Page 11: ...alarm Do not place the alarm where drapes furniture or other objects block the flow of air to the vents 3 Installation Locations CAUTION THIS UNIT IS SEALED INCLUDING THE BATTERY THE COVER IS NOT REMO...

Page 12: ...d Your CO alarm may also be placed on a tabletop If alarm is not wall mounted then be sure the alarm is no more than one metre from the floor to minimize the risk of causing permanent damage to the al...

Page 13: ...or alarm using a screwdriver slide the switch on the back of the unit up to the shut down position Unit will not respond to CO Normal Test Reset function Red LED flashes with beeps 4 quick beeps 5 se...

Page 14: ...ber Red LED flashes every 60 seconds One quick beep every 60 seconds Batteries need to be replaced If unit is cold allow to warm up above 20 C If the unit is at room tem perature and is beeping flashi...

Page 15: ...ations of CO between 1 and 30 PPM can often occur in normal everyday conditions Concentrations of CO below 30 PPM may be an indication of a transient condition that may appear today and never reappear...

Page 16: ...nently damage or temporarily contaminate the sensor Avoid spraying air fresheners hair spray paint or other aerosols near the alarm Do not paint the unit Paint will seal the vents and interfere with p...

Page 17: ...end of life or error mode it is neces sary to turn the unit off This stops it from making a sound and also discharges the remaining capacity of the battery to render it safe 1 Remove the bracket back...

Page 18: ...ny kind resulting from gas leakage fire or explosion This warranty does not affect your statutory rights Warranty Performance During the above warranty period your product will be replaced with a comp...