4. Operation and Testing

OPERATION: 

The smoke alarm is operating once a fresh battery is

installed and testing is complete. When products of combustion are
sensed, the unit sounds a loud 85db pulsating alarm (and activates the
safety light on model i9080 only) until the air is cleared.

HUSH CONTROL: 

The “HUSH” feature has the capability of temporarily

desensitizing the alarm circuit for approximately 8 minutes. This feature
is to be used only when a known alarm condition, such as smoke from
cooking, activates the alarm. Models i9060, i9060RV and i9080 are
desensitized by pushing the “HUSH” button on the smoke alarm cover.
Models i9030, i9040, i9040RV and i9050 are desensitized by pushing
the TEST/HUSH button on the cover. If the smoke is not too dense, the
alarm will silence immediately and the Red LED will flash once every 10
seconds for approximately 8 minutes. This indicates that the alarm is in a
temporarily desensitized condition. The smoke alarm will automatically
reset after approximately 8 minutes and sound the alarm if particles of
combustion are still present. The “HUSH” feature can be used repeated-
ly until the air has been cleared of the condition causing the alarm.

NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEA-
TURE AND SOUND A CONTINUOUS ALARM.   

CAUTION: BEFORE USING THE ALARM HUSH FEATURE, IDENTI-

FY THE SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDI-
TION EXISTS.

FLASHING LED LIGHT: 

This smoke alarm is equipped with a flashing

red indicator light. The light is located under the test button and will
flash every 40 seconds to indicate that the smoke alarm is receiving
power.

TESTING: 

Test by pushing the test button on the cover and holding it

down for a minimum of 5 seconds. This will sound the alarm (and
activate the safety light on model i9080 only) if the electronic circuitry,
horn, and battery are working. If no alarm sounds, the unit has defective
batteries or other failure. DO NOT use an open flame to test your alarm,
you could damage the alarm or ignite combustible materials and start a
structure fire.

TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION.

Erratic or low sound coming from your alarm may indicate a defective
alarm, and it should be returned for service (see section 12).

NOTE: WEEKLY TESTING IS REQUIRED.

!

0930-7206-02_EN:_  2017.4.6  4:10 PM  Page 10

Summary of Contents for 0915E

Page 1: ...this User Guide which should be saved for future reference and passed on to any subsequent owner Smoke Alarm User Guide i9040 and i9040RV 9 Volt Battery Operated Model i9030 i9040 i9040RV i9050 i9060...

Page 2: ...with all family members Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving don t open an...

Page 3: ...F BATTERY WILL RENDER THE SMOKE ALARM INOPERATIVE WARNING TEST YOUR SMOKE ALARM OPERATION AFTER RV OR MOBILE HOME VEHICLE HAS BEEN IN STORAGE BEFORE EACH TRIP AND AT LEAST ONCE A WEEK DURING USE CAUTI...

Page 4: ...alarm detects products of combustion using the ionization tech nique It contains 0 9 microcurie of Americium 241 a radioactive materi al see section 9 Distributed under U S NRC License No 32 23858 01...

Page 5: ...ing the sleeper Smoke heat and combustion products rise to the ceiling and spread horizontally Mounting the smoke alarm on the ceiling in the center of the room places it closest to all points in the...

Page 6: ...easured horizontally see FIGURE 2 Install Smoke Alarms on tray shaped ceilings coffered ceilings on the highest portion of the ceiling or on the sloped portion of the ceiling within 12 305mm verticall...

Page 7: ...fested areas Smoke alarms should not be installed within 3 ft 9m of the following the door to a kitchen the door to a bathroom containing a tub or shower forced air supply ducts used for heating or co...

Page 8: ...acket shown mounting bracket for all other models 5 When wall mounting mount flat side to the wall and rotate mount ing plate approximately 5 to the right as shown The A line should be hori zontal and...

Page 9: ...CAUTION IF THE BATTERY REMINDER FINGER IS NOT HELD DOWN IN THE BATTERY COMPARTMENT BY THE BATTERY THE BAT TERY DOOR WILL NOT CLOSE AND THE UNIT WILL NOT ATTACH TO THE MOUNTING BRACKET NOTE THE I9030...

Page 10: ...ombustion are still present The HUSH feature can be used repeated ly until the air has been cleared of the condition causing the alarm NOTE DENSE SMOKE WILL OVERRIDE THE HUSH CONTROL FEA TURE AND SOUN...

Page 11: ...tion of the OFF arrow on the cover see FIGURE 8 i9030 i9040 i9050 i9060 and i9080 Smoke Alarms are powered by a 9V carbon zinc battery alkaline batteries may also be used A fresh bat tery should last...

Page 12: ...d with a damp cloth After cleaning reinstall your alarm and test your alarm by using the test button If cleaning does not restore the alarm to normal operation the alarm should be replaced LED SAFETY...

Page 13: ...ionization alarms A battery powered alarm must have a battery of the specified type in good condition and installed properly AC powered alarms without battery backup will not operate if the AC power...

Page 14: ...order to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do Install and maintai...

Page 15: ...ces and unfinished attics 5 In the living area s of a guest suite 6 In the living area s of a residential board and care occupancy small facility Are More Smoke Alarms Desirable The required number of...

Page 16: ...to enable detection of visible and invisible combustion products The radioactive element is safely contained in the chamber and requires no adjustments or mainte nance This smoke alarm meets or exceed...

Page 17: ...S PARENT OR SUBSIDIARY CORPO RATIONS ARISING FROM THE SALE OF THIS SMOKE ALARM OR UNDER THE TERMS OF THIS LIMITED WARRANTY SHALL NOT IN ANY CASE EXCEED THE COST OF REPLACEMENT OF SMOKE ALARM AND IN NO...

Page 18: ...NS OR FOR MORE INFORMATION Call our Consumer Hotline at 1 800 880 6788 or contact us at our website at www kidde com Kidde 1016 Corporate Park Drive Mebane NC 27302 0930 7206 02_EN _ 2017 4 6 4 10 PM...

Reviews: