Recommended Locations

• Locate the first alarm in the immediate area of the

bedrooms.  Try to protect the exit path, as the
bedrooms are usually farthest from the exit.  If more
than one sleeping area exists, locate additional alarms
in each sleeping area (Image 1A).

• Locate additional alarms to protect any stairway as

stairways act like chimneys for smoke and heat.

• Locate at least one alarm on every floor level (Image 1B).

• Locate an alarm in every bedroom.

• Locate an alarm in every room where electrical

appliances are operated (i.e. portable heaters or
humidifiers).

• Locate an alarm in every room where someone sleeps

with the door closed.  The closed door may prevent
the alarm from waking the sleeper.

• Smoke, heat, and combustion products rise to the

ceiling and spread horizontally.  Mounting the smoke
alarm on the ceiling in the center of the room places it
closest to all points in the room.  Ceiling mounting is
preferred in ordinary residential construction.

• When mounting an alarm on the ceiling, locate it at a

minimum of 10 cm (4") from the side wall (Image 2A).

• When mounting the alarm on the wall, use an inside

wall with the top edge of the alarm at a minimum of
10 cm (4") and a maximum of 30.5 cm (12") below the
ceiling (Image 2A).

• Put smoke alarms at both ends of a bedroom hallway

or large room if the hallway or room is more than
9.1 m (30') long.

• For mobile home installation, select locations carefully

to avoid thermal barriers that may form at the ceiling.
For more details, see 

Mobile Homes

.

WARNING:  Battery door will not close unless battery is present.
Removal of battery will render the smoke alarm inoperative.

NOTE:  Any statements referring to a battery, applies to both
batteries used with model 0918CA.

Introduction  . . . . . . . . . . . . . . . . . . . . . . . . 1

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-10

Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . 11-14

Fire Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . 15-18

Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20

C o n t e n t s

I n t ro d u c t i o n

I n s t a l l a t i o n

2

Models

0915CA, 0916CA, PE9CA 

and

0918CA

Thank you for purchasing this smoke alarm.  It is an
important part of your family’s home safety plan.  You
can trust this product to provide the highest quality safety
protection.  We know you expect nothing less when the
lives of your family are at stake. 

Please take a few minutes to thoroughly read this alarm
manual, and save it for future reference.  Teach children
how to respond to the alarms, and that they should never
play with the unit. 

If you have any questions about the operation or
installation of your alarm, please call our toll free
Consumer Hotline at 1-800-880-6788. 

Image 1C will help you determine the correct location of
safety products that will help make your home a safer place.

IMPORTANT:  Read all instructions before installation and keep
this manual near the alarm for future reference.
Do not try to repair the smoke alarm yourself.  Refer to the
instructions in Warranty section for service.

1

Made in China.  Patents Pending

130 Esna Park Drive, Markham ON   L3R 1E3

Consumer Hotline: 1-800-880-6788

w w w. k i d d e . c a

0918-7227-02_DC_MAN_ENG  10/5/04  4:40 PM  Page 2

Summary of Contents for 0915CA

Page 1: ...Smoke Alarm Manual 0915CA 0916CA PE9CA 0918CA SINGLE STATION SMOKE ALARM For alarm models...

Page 2: ...cations carefully to avoid thermal barriers that may form at the ceiling For more details see Mobile Homes WARNING Battery door will not close unless battery is present Removal of battery will render...

Page 3: ...install in peaks of vaulted ceilings A frame ceilings or gabled roofs Less than 10 cm 4 from the peak of an A frame type ceiling Install at least 30 5 cm 12 away from fluorescent lights as electronic...

Page 4: ...mounting plate must be parallel with the hallway when ceiling mounted or horizontal when wall mounted Image 3A Secure the mounting plate to the wall or ceiling with the anchors and screws provided Ima...

Page 5: ...transferred from the outside to the inside through poorly insulated walls and roof This may create a thermal barrier that can prevent the smoke from reaching an alarm mounted on the ceiling In such u...

Page 6: ...nd 0918CA are designed to detect products of combustion using the ionization technique They contain 0 9 microcurie of Americium 241 a radioactive material Distributed under U S NRC License No 32 23858...

Page 7: ...eature may have been activated accidentally while changing the battery ies and will reset automatically Testing CAUTION Due to the loudness 85 decibels of the alarm always stand an arms length away fr...

Page 8: ...batteries for powering the safet light Alkaline Type Energizer 522 Duracell MN1604 or MX1604 These batteries can be purchased at your local retailer The safety light has a 6 3 V 250mA fuse lamp with...

Page 9: ...cannot provide an alarm if smoke does not reach the alarm Therefore smoke alarms may not sense fires starting in chimneys walls on roofs on the other side of a closed door or on a different floor Fire...

Page 10: ...larm installation Alarm Exit Procedure Alert small children in the home Leave immediately by your escape plan Every second counts so don t waste time getting dressed or picking up valuables In leaving...

Page 11: ...riting signed by both parties hereto If after reviewing this manual you feel that your smoke alarm is defective in any way do not tamper with the unit In many cases the quickest way to exchange your a...

Page 12: ...Notes 21...

Reviews: