LCD OPERATION

Controller temperature 
exceeds 158ºF 

(70ºC)

Power off and wait until the temperature 
decrease back to normal about 10 min

utes.

Motor Hall is abnormal

1. Is the connection between motor and controller

loose or broken?

2. Motor requires repair.

Motor overcurrent

1. Shutdown and restart the system.
2. Motor requires repair.

Wheel diameter Sensor abnormal

Check wheel sensor or wheel magnet

Voltage too high
48V system: battery is above 60V
36V system: battery is above 44V

Replace the battery.

Lost or abnormal communication 
between LCD and controller.

1. Shutdown and restart the system.
2. Is the wire between the LCD and controller

loose or broken?

3. Controller or LCD may require repair.

8

6

9

15

14

17 

13

Summary of Contents for Extended 2.0

Page 1: ......

Page 2: ...1...

Page 3: ...d on the left side to the frame Standing on the left side of the bike gives you more leverage Turn the battery key counter clockwise Hold the battery pack with your right hand and prepare your left ha...

Page 4: ...to the bike Hold the battery pack with both hands line up the connector socket on the bottom and push the battery pack to the right bracket completely Turn the battery key clock wise to lock the batt...

Page 5: ...that the battery and the charger are both rated 48V Plug the charge output 2 into the battery charge input 3 Charger connect to AC power source 1 Household 110V 220V socket 4 is USB port CHARGING THE...

Page 6: ...upplier for service We recommend fully charging the battery after every ride 5 4 Green LED represent fully charged 1 Red LED represents charge needed LED indicator 8 Red light indicates charging Green...

Page 7: ...l automatically shut OFF after 60 minutes of being idle However to ensure longer battery life you may turn OFF the battery manually by pressing the power button again Simply press the power button to...

Page 8: ...6V 36 42 V Envoy 200 48V 48 54 V Extended 2 0 48V 48 54 V Model Battery Charger Chart 7 a It is strictly forbidden to charge the battery with an uncertified charger b Avoid direct sunlight Charge in d...

Page 9: ...nd battery level indicators section 8 1 POWER output indicator Each cell means 2A current of output 2 BATTERY level indicator LCD OPERATION On Off When the battery is empty all six cells are blank and...

Page 10: ...to increase power assistance level 0 1 2 3 4 5 Push to decrease power assistance level 5 4 3 2 1 0 Push and simultaneously for 2 seconds to change the speed unit between Miles Per Hour MPH and Kilome...

Page 11: ...Indicator section NOTE 2 To clear all info except for odometer push and together for 2 seconds NOTE 3 To clear all info including odometer push and together for 10 seconds 3 10 Screen cycles through t...

Page 12: ...l panel button for 2 seconds to start the walking mode Button must be held to continue walking mode Releasing the button will immediately stop the walking mode Walking mode will allow the motor to run...

Page 13: ...goes away If it does the wire maybe shorted Crank sensor no signal or no phase At power on with power assistance level 0 error code 4 may appear The code should disappear automatically after 30 secon...

Page 14: ...otor overcurrent 1 Shutdown and restart the system 2 Motor requires repair Wheel diameter Sensor abnormal Check wheel sensor or wheel magnet Voltage too high 48V system battery is above 60V 36V system...

Page 15: ...NOTES 14...

Page 16: ...KHS Inc 2840 E Harcourt St Rancho Dominguez CA 90221 USA Tel 310 632 7173 Press 2 khsbicycles com...

Reviews: