Exquisite MP1000-R Specifications

 

  

Circuit type 

Linear amplifier topology 

Output power 

 
 
Max peak output power 

400W (8

800W (4

1600W (2

2700W (current limited for safety) 

Frequency response 

4Hz to 180kHz (+0, -3dB Filtered at the input) 

Output impedance 

0 Ohms 

THD+N 

-120Db 

IMD 

-120Db 

Damping factor 

Larger then 2000 

Output Connection 

Spades 

Input Connection 

XLR / RCA 

Gain 

26dB 

Sensitivity 

2.6V 

Input impedance 

10k

 (each input to gnd) 

 

 

Fuse Rating (120V version) 

6.3x32mm; 8A 250V AC; antisurge** 

Fuse Rating (230V version) 

6.3x32mm, 4A 250V AC; antisurge** 

Height (in/cm) 

8.9 / 22.5 

Depth (in/cm) 

26.7 / 67.8 

Width (in/cm) 

17.7 / 45.0 

Weight (lbs/kg) 

176 / 80 Kg. 

 

 

 

 

** Depending on voltage in your country, please contact your dealer to make sure 
which type of fuse should be used. 

Summary of Contents for Exq-MP1000-R

Page 1: ...EXQUISITE MP1000 Reference mono power amplifier Exq MP1000 R...

Page 2: ...be taken to install and operate your new amplifiers Please read this manual carefully and totally prior to installation Unpacking Upon opening the wooden box inspect the Amplifiers carefully for any s...

Page 3: ...is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons Th...

Page 4: ...is unit 8 Never block air flow through ventilation slots or heat sinks 9 Never bypass any fuse 10 Never replace any fuse with a value or type other than specified 11 Never attempt to repair this produ...

Page 5: ...ng the loudspeakers If the problem occurs on the other channel this time it is probably your loudspeaker that is malfunctioning Switch the connections at your pre amplifier connect the MP1000 that was...

Page 6: ...the back of your Exquisite MP1000 you will find the connection panel which looks like the picture below It shows the standard back with XLR input on customer demand the XLR can be replaced with an RC...

Page 7: ...n the configuration of the amplifier If you are not sure about the voltage to which your amplifier is configured please contact your dealer DO NOT switch on the power until all wiring is connected cor...

Page 8: ...ton B for less then one second It will take about ten seconds for the amplifier to start up When the amplifier is ready the indicator light will turn to blue When you want to put the amplifier back in...

Page 9: ...the necessary voltage for a short period of time Panic button Button A on the left can always be used as a panic button In case of emergency simply press button A and the amplifier will turn off comp...

Page 10: ...120Db Damping factor Larger then 2000 Output Connection Spades Input Connection XLR RCA Gain 26dB Sensitivity 2 6V Input impedance 10k each input to gnd Fuse Rating 120V version 6 3x32mm 8A 250V AC an...

Page 11: ...s warranty includes parts and labour This warranty is not automatically transferable subsequent owners can request a warranty at the factory B Warranty Exclusions 1 Transportation damage visible or hi...