4.3.3
System services
The menu “system services“ can be retrieved for approx 10 minutes after the supply voltage has been established. No further adjustments can be
made afterwards. The 10 minutes are available once again after the supply voltage has been disconnected and reconnected.
The following functions can be carried out in the menu „system services“:
Function
LED
explanation
Couple devices
All devices connected via the SI-BUS (SIEGENIA access control system, SI-BUS I/O-module etc.) are successively
integrated into the system.
All successfully connected devices are acknowledged by a signal tone on the respective device.
The A-opener 2.2 is the master device.
Separate devices
All devices that are no longer connected to the SI-BUS will be removed from the SI-BUS.
They must no longer be connected to the A-opener 2.2.
All devices that are still connected to the SI BUS remain coupled.
Unblock ACS
SIEGENIA access control systems ACS (fingerprint scanner, transponder, keypad), which are blocked for a specific
time due to too many false entries, can be unblocked prior to expiry of this time with this function.
Factory settings
The following adjustments are reset to the factory settings:
all device couplings, the complete user administration, all device names, all system names,
the WIFI configuration, all protocol log entries (ACS), the keyless settings
WIFI on
Switches on the WIFI function. The SIEGENIA Comfort APP can be used.
WIFI off
Switches off the WIFI function. The SIEGENIA Comfort APP can not be used.
Menu structure
Operating sequence
Step
Press the menu
button
LED lights up
blue
LED
explanation
1
8 s
Magenta
Retrieve menu settings
2
2 x 1 s
Bright red
Change to menu „System services“
3
3 s
Bright red/
white
Call up "system services" menu
4
(X) x 1 s
to
Bright red/
white
Bright red/
Violet
Change to the desired function:
„Couple device“ -> „Disconnect device“ ->
„Unblock ACS“ -> „Factory settings“ -> „WIFI on“ -> „WIFI off“
5
3 s
(Example)
Execution of the function
Le
vel 1
System
services
Le
vel 2
Couple
devices
Separate
devices
Unblock
ACS
Factory
settings
WIFI on
WIFI off