10. Your unit may come with internal packaging. 
    This packaging must be removed prior to 
    installing the air conditioner back into the 
    cabinet.(see Fig.7).

2

Install Top Angle and 

Side Bracket

1. Attach foam gasket to top angle 
    above holes as shown in Fig.6.
2. Install top angle and side retainers
    to cabinet as shown in Fig.8 (10 sc-
    rews).

3

Assemble W indow Filler Panels

1. Place cabinet on floor, a bench, or 
    a table.
2. Slide 

I  

section of window filler panel

     into side  retainer on the side of the
     cabinet (see Fig.9 & Fig.10). 
     Do both sides. 

,,

,,

Plastic
Frame

Window Filler
Panel

Side Retainer

Fig.9

5 1

6  l

ong

hex

-he

ad

/

Shipping Packaging

Plastic tie

Fig.7

Fig.8

3. Insert top and bottom legs of window
    filler panel frame into channel in the 
    top angle and bottom rail. Do both 
    sides.
4. Insert washer head locking 7/16" screws
    (2) into holes in top leg of filler panel
    frame (see step 6). Do not totally tigh-
    ten. Allow leg to slide freely. Screws 
    will be tightened after section 6.

4

Place Cabinet in

1.Open window and mark center of window stool as
    shown(Fig.11).
2. Place cabinet in window with bottom stool angle
    firmly seated over window stool as shown. Bring
    window down temporarily behind top  angle to 
    hold cabinet in place(Fig.12).

Stool

Stool
Angle

Top
View

Air Conditioner
Cabinet

Plastic
Frame

"

"  Section

Window

Filler

Panel

Locking

Screw

Hole

Fig.10

Fig.11

Fig.12

3. Shift cabinet left or right as needed to line up 
    center of cabinet on center line marked on stool.
4. Fasten cabinet to window stool with 2 screws 
    into holes(You may wish to pre-drill pilot holes).
5. Add bottom rail seal over screws to window stool.

Summary of Contents for KSTAW18C

Page 1: ...KSTHW18A KSTHW25A...

Page 2: ......

Page 3: ...Producto...

Page 4: ...1 866 646 4332 1 866 646 4332 MIDEA AMERICA CORPORATION PRODUCT REGISTRATION CENTER 11800 NW 100 ROAD STE 4 MEDLEY FL 33178 1037...

Page 5: ...xcess heat generation It may cause electric shock or fire due to heat generation Incorrect grounding may cause electric shock It may cause fire and electric shock It may cause fire It may cause explos...

Page 6: ...ters maycause failure It contains contaminants and could make you sick Stop operation and close the window in storm or hurricane Do not use strong detergent such as wax or thinner but use a soft cloth...

Page 7: ...he window is a triple track type with a screen panel included remove the screen completely before installation Be sure the air conditioner has been securely and correctly installed according to the in...

Page 8: ...on and these Installation Instructions for future reference The carton is the best way to store unit during winter or when not in use NOTE Preliminary Instructions Do the following before starting to...

Page 9: ......

Page 10: ...dow filler panel frame into channel in the top angle and bottom rail Do both sides 4 Insert washer head locking 7 16 screws 2 into holes in top leg of filler panel frame see step 6 Do not totally tigh...

Page 11: ...1 Carefully raise window to expose filler panel locking screws Loosen screws so filler panels slide easily 2 Extend panels to fill window opening completely Tighten locking screws on top Fig 17 3 Ins...

Page 12: ...1 Lift air conditioner and carefully slide into cabinet leaving 6 inches protruding 2 DO NOT push on controls or finned coils 3 Be sure chassis is firmly seated towards rear of cabinet 4 Installation...

Page 13: ...Slide the R1 insulation panel into the side curtain the side with pattern should facing the indoor side Fig 22 INSTALL WEATHER STRIPPING only be applicable to Energy star models 11 In order to minimiz...

Page 14: ...e provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 does not support major structural loads such as the frame construction at ends of windows and und...

Page 15: ...binet wooden frame using shims if frame is oversized to eliminate distortion See Fig 8 Remember to maintain proper slop as described in Step 3 Fig 8 OPTIONAL Caulking and installation of trim on inter...

Page 16: ...e on Fan Only section CLEAN AIR FEATURE on some models Press Clean Air button the ion generator is energized and will help to removepollenand impurities from the air and trap them in the filter Sleep...

Page 17: ...selected temperature This ends the Sleep mode and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by pressing the Sleep...

Page 18: ...e circuit breaker tripping The fan will continue to run during this time The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other pres...

Page 19: ...ed Push plug firmly into wall outlet House fuse blown or circuit breaker tripped Replace fuse with time delay type or reset circuit breaker Plug Current Device Tripped Press the RESET button Problem A...

Page 20: ...ing Water dripping INSIDE when unit is cooling Improper installation Tilt air conditioner slightly to the outside to allow water drainage Refer to installation instructions check with installer Dirty...

Page 21: ......

Page 22: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Reviews: