374
Keysight P9241/42/43A Oscilloscopes SCPI Programmer's Guide
17
:FUNCtion<m> Commands
:FUNCtion<m>:OPERation
Command Syntax
:FUNCtion<m>:OPERation <operation>
<m> ::= 1 to (# math functions) in NR1 format
<operation> ::= {ADD | SUBTract | MULTiply | DIVide | DIFF | INTegrate
| FFT | FFTPhase | SQRT | MAGNify | ABSolute | SQUare | LN | LOG
| EXP | TEN | LOWPass | HIGHpass | AVERage | SMOoth | ENVelope
| LINear | MAXimum | MINimum | PEAK | MAXHold | MINHold | TRENd}
The :FUNCtion<m>:OPERation command sets the desired waveform math
operator, transform, filter or visualization:
• Operators:
•
ADD — S source2.
•
SUBTract — Source1 - source2.
•
MULTiply — Source1 * source2.
•
DIVide — Source1 / source2.
Operators perform their function on two analog channel sources.
• Transforms:
•
DIFF — Differentiate
•
INTegrate — The INTegrate:IOFFset command lets you specify a DC offset
correction factor.
•
FFT (magnitude) — Using the Fast Fourier Transform (FFT), this operation
displays the magnitudes of the frequency content that makes up the source
waveform. The FFT takes the digitized time record of the specified source
and transforms it to the frequency domain.
The SPAN, CENTer, VTYPe, and WINDow commands are used for FFT
functions. When FFT is selected, the horizontal cursors change from time to
frequency (Hz), and the vertical cursors change from volts to decibels or
V RMS.
•
FFTPhase — Using the Fast Fourier Transform (FFT), this operation shows
the phase relationships of the frequency content that makes up the source
waveform. The FFT takes the digitized time record of the specified source
and transforms it to the frequency domain.
The SPAN, CENTer, VTYPe, and WINDow commands are used for FFT
functions. When FFTPhase is selected, the horizontal cursors change from
time to frequency (Hz), and the vertical cursors change from volts to degrees
or radians.
•
LINear — Ax + B — The LINear commands set the gain (A) and offset (B)
values for this function.
Summary of Contents for P9241
Page 1: ...Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 6: ...6 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide...
Page 36: ...36 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 1 What s New...
Page 41: ...Setting Up 2 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 41...
Page 44: ...44 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 2 Setting Up...
Page 222: ...222 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 7 Root Commands...
Page 244: ...244 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 8 ACQuire Commands...
Page 256: ...256 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 9 CALibrate Commands...
Page 278: ...278 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 10 CHANnel n Commands...
Page 328: ...328 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 15 EXTernal Trigger Commands...
Page 386: ...386 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 17 FUNCtion m Commands...
Page 390: ...390 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 18 HCOPY Commands...
Page 416: ...416 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 20 MARKer Commands...
Page 498: ...498 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 21 MEASure Commands...
Page 532: ...532 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 22 MTESt Commands...
Page 572: ...572 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 24 SAVE Commands...
Page 900: ...900 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 28 TIMebase Commands...
Page 1080: ...1080 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 31 WGEN w Commands...
Page 1142: ...1142 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide 34 Error Messages...
Page 1344: ...1344 Keysight P9241 42 43A Oscilloscopes SCPI Programmer s Guide Index...