Safety and Regulatory Information 

Introduction

Review this product and related documentation to familiarize yourself with safety 
markings and instructions before you operate the instrument. 

This product has been designed and tested in accordance with accepted industry 
standards, and has been supplied in a safe condition. The documentation contains 
information and warnings that must be followed by the user to ensure safe operation 
and to maintain the product in a safe condition.

Safety Earth Ground

Declaration of Conformity

A copy of the Declaration of Conformity is available upon request, or a copy is available 
on the Keysight Technologies web site at 

http://regulations.about.keysight.com/DoC/search.htm

Statement of Compliance

This product has been designed and tested in accordance with accepted industry 
standards, and has been supplied in a safe condition. The documentation contains 
information and warnings that must be followed by the user to ensure safe operation 
and to maintain the product in a safe condition.

This is a Safety Class I Product (provided with a protective earthing ground 

incorporated in the power cord). The mains plug shall be only be inserted in a 

socket outlet provided with a protective earth contact. Any interruption of the 

protective conductor inside or outside of the product is likely to make the 

product dangerous. Intentional interruption is prohibited.

Always use the three prong AC power cord supplied with this product. Failure 
to ensure adequate earth grounding by not using this cord may cause product 
damage and the risk of electrical shock.

24

Keysight N5256/7/8A/B User's Guide

Summary of Contents for N5256A

Page 1: ...User s Guide Keysight Technologies N5256 7 8A B Millimeter wave Module...

Page 2: ...Software to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula Th...

Page 3: ...duction 24 Safety Earth Ground 24 Declaration of Conformity 24 Statement of Compliance 24 Before Applying Power 25 Servicing 26 Connector Care and Cleaning Precautions 26 Electrostatic Discharge Prote...

Page 4: ...6AW15 N5257AR15 and N5258AD15 the LO multiplier number has changed from 5 to 6 Modules with OML s n 16xxxx made before 2017 have the LO multiplier number 5 indicated on the module s rear label and are...

Page 5: ...N5256 7 8A B N5256 7 8A B Keysight N5256 7 8A B User s Guide 1...

Page 6: ...em configuration information refer to the Keysight Millimeter wave Network Analyzer 10 MHz to 110 GHz with Extensions to 1 1 THz 5989 7620EN available on the Keysight Technologies web site at http lit...

Page 7: ...reflection coefficient only The N5257A B T Millimeter wave Module is a receive only module that contains a test downconverter to receive the test signal from a T R Millimeter wave Module The use of a...

Page 8: ...s a 3 32 inch captive screw and VDI supplies a 5 64 inch captive screw The millimeter wave modules have adjustable feet for leveling height when connecting to other equipment For indoor use only Do no...

Page 9: ...AW12 60 to 90 GHz WR 12 N5256AW15 50 to 75 GHz WR 15 N5256AW22 33 to 50 GHz WR 22 N5256AX10 67 to 110 GHz WR 10 N5256AX12 56 to 94 GHz WR 12 Table 5 N5257A Waveguide Model and Options1 Waveguide Modul...

Page 10: ...WR 08 N5258AD10 75 to 110 GHz WR 10 N5258AD12 60 to 90 GHz WR 12 N5258AD15 50 to 75 GHz WR 15 N5258AD22 33 to 50 GHz WR 22 Table 7 N5256B Waveguide Model and Options1 Waveguide Modules Frequency Rang...

Page 11: ...cluded WR 15 Receiver module LO x6 cables not included 1 Waveguide models maybe ordered with Option 001 15 dB Gain LO Internal Amplifier Table 9 N5258B Waveguide Model and Options1 Waveguide Modules F...

Page 12: ...formance Graphs and Certificate of Compliance Millimeter wave Module Refer to Table 9 Table 10 and Table 11 for your specific module Model N5256A B includes a Waveguide Section Model N5257A W02 W03 an...

Page 13: ...260 80047 V12VNA2 TR 5694 N5256A B Option 0011 N5256AW03 001 N5260 80038 V03VNA2 T R A N5256AW05 001 N5260 80035 V05VNA2 T R A N5256AW06 001 N5260 80044 V06VNA2 T R A N5256AW08 001 N5260 80116 V08VNA2...

Page 14: ...5 N5256AW03 004 N5260 80058 V03VNA2 T R N5256AW10 004 N5260 80055 V10VNA2 T R N5256A Option HLP N5256AW10 HLP N5260 80227 V10VNA2 T R LP N5256AW12 HLP N5260 80228 V12VNA2 T R LP N5256AW15 HLP N5260 8...

Page 15: ...NA2 T R IMD 1 Waveguide models with Option 001 Adjustable RF Attenuator 2 Waveguide models with Option 002 15 dB Gain RF and LO Internal Amplifiers 3 Waveguide models with Option 003 Option 001 and Op...

Page 16: ...60 80071 V03VNA2 T LOA N5257AR05 001 N5260 80070 V05VNA2 T LOA N5257AR06 001 N5260 80069 V06VNA2 T LOA N5257AR08 001 N5260 80068 V08VNA2 T LOA N5257AR10 001 N5260 80067 V10VNA2 T LOA N5257AR12 001 N52...

Page 17: ...1 TBA V08VNA2 T2 LOA N5258AD10 001 N5260 80029 V10VNA2 T2 LOA N5258AD12 001 N5260 80211 V12VNA2 T2 LOA N5258AD15 001 N5260 80031 V15VNA2 T2 LOA Table 12 N5258A B Waveguide Models Continued Keysight Mo...

Page 18: ...N5256 7 8A B Front and Rear Panel Features Front and Rear Panel Features Figure 2 Rear Panel Power Supply Connector Pin 3 12V Pin 1 12V Pin 4 gnd Pin 6 gnd 14 Keysight N5256 7 8A B User s Guide...

Page 19: ...N5256 7 8A B Front and Rear Panel Features Figure 3 N5256A B or N5257A B Front Panel Figure 4 N5256A B Rear Panel Keysight N5256 7 8A B User s Guide 15...

Page 20: ...6 7 8A B Front and Rear Panel Features N5256A B Option 001 003 or 004 Figure 6 N5257A B Single Receiver Rear Panel Opt 004 IF Jumper Ports Opt 001 or 003 Adjustable Attenuator 16 Keysight N5256 7 8A B...

Page 21: ...Figure 7 N5256 7 8A B Front and Rear Panel Features N5258A B Dual Receiver Front Panel Figure 8 N5258A B Dual Receiver Rear Panel Keysight N5256 7 8A B User s Guide 17...

Page 22: ...N5256 7 8A B Block Diagrams Block Diagrams Figure 9 N5256A B Standard 18 Keysight N5256 7 8A B User s Guide...

Page 23: ...Figure 10 N5256 7 8A B Block Diagrams N5256A Option 004 Jumper 1 Jumper 2 Keysight N5256 7 8A B User s Guide 19...

Page 24: ...N5256 7 8A B Block Diagrams Figure 11 N5257A B 20 Keysight N5256 7 8A B User s Guide...

Page 25: ...t Port 2 Test Port 1 Precision Attenuator IF Amplifier and or LTF 300 MHz IF Amplifier and or LTF 300 MHz Test IF 1 Test IF 2 TBD for WR 03 and WR 04 10 dB for WR 05 WR 06 WR 08 20 dB for WR 10 WR 12...

Page 26: ...Dimensions Figure 13 VNA2 T R Series Modules 13 0 4 3 DC Power RF Input LO Input Test Port Test IF Ref IF 2 7 2 1 2 1 4 Feet diameter 3 adj foot 13 thd in 1 4 1 4 11 4 0 5 22 Keysight N5256 7 8A B Use...

Page 27: ...N5256 7 8A B Drawings and Dimensions Figure 14 VNA2 T Series Modules 4 7 2 7 4 3 Keysight N5256 7 8A B User s Guide 23 Weight of VNA2 T Series Module 3 0 lbs...

Page 28: ...ht com DoC search htm Statement of Compliance This product has been designed and tested in accordance with accepted industry standards and has been supplied in a safe condition The documentation conta...

Page 29: ...and serious injury This product is designed for use in Installation Category II and Pollution Degree 2 Verify that the premise electrical voltage supply is within the range specified on the instrument...

Page 30: ...readily identifiable and easily reached by the operator may be used as a disconnecting device The power cord is connected to internal capacitors that may remain live for 5 seconds after disconnecting...

Page 31: ...when making connections always wear a heel strap 9300 1126 when working in an area with a conductive floor If you are uncertain about the conductivity of your floor wear a heel strap always ground yo...

Page 32: ...il address is required by EU directives applicable to our product The CSA mark is a registered trademark of the CSA International This is a symbol of an Industrial Scientific and Medical Group 1 Class...

Page 33: ...e a la norme NMB 001 du Canada Acoustic Statement European Machinery Directive Acoustic noise emission LpA 70 dB Operator position Normal operation mode Per ISO 7779 Keysight N5256 7 8A B User s Guide...