Installation Note N5247-90106 47
Installation Procedure for the Upgrade
— W79 (reuse) (N5242-60012) A24 IF multiplexer board P3 to A16
SPAM board J1
— W81 (reuse) (N5242-60014) A24 IF multiplexer board P403 to A16
SPAM board J4
— W83 (reuse) (N5242-60016) A24 IF multiplexer board P803 to A16
SPAM board J6
Step 41. Reinstall the Testset Stabilizer Bracket on the A24 IF
Multiplexer Board
Reinstall the stabilizer bracket - see
.
Step 42. Reinstall the A23 Test Set Motherboard
1. For instructions on reinstalling the board, click the Chapter 7 bookmark
“Removing and Replacing the A23 test set motherboard” in the PDF
Service Guide
Step 43. Install Cables on the A23 Test Set Motherboard
If not already done in a previous step, install the following new ribbon cables
and wire harness in the order listed. To see an image showing their locations,
click the Chapter 6 bookmark “Bottom Ribbon Cables and Wire Harnesses,
4-Port, Option 419” in the PDF Service Guide
1
. New parts are listed in
— Ribbon cable (N5247-60015) from A28 mixer brick (2) J52 to A23 test set
motherboard J552
— Ribbon cable (N5247-60018), A61 port 3 70 GHz doubler J1 to A23 test set
motherboard J5
— Ribbon cable (N5247-60018), A62 port 4 70 GHz doubler J1 to A23 test set
motherboard J3
— Ribbon cable (N5247-60021), A43 port 3 bias tee to A23 test set
motherboard J543
— Ribbon cable (N5247-60021), A44 port 4 bias tee to A23 test set
motherboard J544
— Ribbon cable (N5247-60020), A47 port 3 receiver attenuator to A23 test set
motherboard J206
Follow instructions carefully when making cable connections, especially
wire harness connections. Incorrect connections can destroy components,
resulting in additional customer costs.
1. See