Utility Settings
22
Keysight InfiniiVision 3000T X-Series Oscilloscopes User's Guide
347
•
“To load the default label library"
•
•
“To set Autoscale preferences"
To choose "expand about" center or ground
When you change a channel's volts/division setting, the waveform display can be
set to expand (or compress) about the signal ground level or the center of the
display.
To set the waveform expansion reference point:
1
Press
[Utility] > Options > Preferences > Expand
and select:
•
Ground
— The displayed waveform will expand about the position of the
channel's ground. This is the default setting.
The ground level of the signal is identified by the position of the ground level
(
) icon at the far-left side of the display.
The ground level will not move when you adjust the vertical sensitivity
(volts/division) control.
If the ground level is off screen, the waveform will expand about the top or
bottom edge of the screen based on where the ground is off screen.
•
Center
— The displayed waveform will expand about the center of the display.
To disable/enable transparent backgrounds
There is a preference setting for whether measurements, statistics, reference
waveform information, and other text displays have transparent or solid
backgrounds.
1
Press
[Utility] > Options > Preferences
.
2
Press
Transparent
to toggle between transparent and solid text display
backgrounds.
To load the default label library
Summary of Contents for DSOX3012T
Page 78: ...78 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 88: ...88 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 98: ...98 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 4 FFT Spectral Analysis...
Page 148: ...148 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 7 Digital Channels...
Page 154: ...154 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 8 Serial Decode...
Page 160: ...160 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 9 Display Settings...
Page 232: ...232 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 13 Acquisition Control...
Page 242: ...242 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 14 Cursors...
Page 288: ...288 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 16 Mask Testing...
Page 320: ...320 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 19 Waveform Generator...
Page 340: ...340 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 21 Print Screens...
Page 374: ...374 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 23 Web Interface...
Page 394: ...394 Keysight InfiniiVision 3000T X Series Oscilloscopes User s Guide 24 Reference...