CHANnel{1|4}:REFerence <numeric_value>
This command sets the reference value for channel 1 or 4 for the current reference
position.
Syntax
Parameter
Example
CHAN
Space
?
numeric_value
:REF
1
4
Item
Description/Default
Range of values
numeric_value
A numeric value for the channel reference:
– Default value: 0
– Minimum value: –99 dBm/0 W
– Maximum value: 99 dBm/1 W
–99 dBm to 99 dBm
0 W to 1 W
CHAN1:REF 11.75
This command sets the top reference to 11.75 dBm.