3
Specifications
22
Keysight 8710x Operating and Service Manual
General Specifications
Supplemental specifications (cold switching)
illustrates the maximum incident CW power (cold switching) from 100 MHz to 26.5 GHz.
The reference conditions are as below:
– Cold switching only (NO hot switching)
– Ambient temperature of 75
°
C or less
– Sea level (0.88 derating at 15,000 feet)
– Low VSWR < 1.2 (See
for derating above 1.2 VSWR)
Figure 3-1
Maximum incident power (cold switching) vs. frequency
Table 3-1
General specifications
Keysight model number
87104P/Q/R and 87106P/Q/R
Maximum power rating
1 watt average into 50
Ω
internal loads
Hot switching
1 watt CW
50 W peak, 10
μ
s max pulse width, not to exceed 1 W average.
Cold switching
See
Supplemental specifications (cold switching)
Life
3,000,000 cycles minimum
Switching speed
15 ms maximum