background image

 26                                                                                                       Operating and Service Guide 85059-90015

85059G 1.0 mm Connector Gage
Replaceable Parts

-

Summary of Contents for 85059G

Page 1: ...Operating Service Guide Keysight 85059G 1 0 mm Connector Gage...

Page 2: ...U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license s...

Page 3: ...to do the work or need advice contact Keysight Contacting Keysight Assistance with test and measurements needs and information on finding a local Keysight office are available on the Web at http www k...

Page 4: ...r gages kit contents If you have problems with any item in the kit refer to www keysight com and the Contact Keysight link Printing Copies of Documentation from the Web To print copies of documentatio...

Page 5: ...l indicates hazardous voltages This symbol indicates that the instrument requires alternating current ac input The CE mark is a registered trademark of the European Community If it is accompanied by a...

Page 6: ...ial suffix which is unique to each instrument The contents of this manual apply directly to instruments having the serial number prefixed US5830 Manual changes Supplement A gage set manufactured after...

Page 7: ...rmance standards or limits against which the connector gage kit is tested Each gage set is mechanically measured at the factory These factory measurements are traceable to the U S A National Institute...

Page 8: ...ristics Nominal Value Net weight 2 6 kg 5 73 lbs Battery Life Approximately 500 hours in continuous operation Conditions Value or Range Measurement range 0 005 in 0 127 mm to 0 005 in 0 127 mm Calibra...

Page 9: ...epth Limitsc Adapter 0 0002 to 0 0010 in 0 0040 to 0 0240 mm 0 0002 in 0 0040 mm 0 0000 to 0 0012 in 0 0000 to 0 0280 mm 0 0004 to 0 0010 in 0 0004 to 0 0008 mm a Calculated with coverage factor k 2 b...

Page 10: ...entative Storage and Shipment Environment The gage kit should be stored in a clean dry environment The following limitations apply to both storage and shipment Original Packaging Containers and materi...

Page 11: ...ination 4 Turn only the connector nut not the gage itself nor the connected device i e set master adapter or calibration standard when making connection to avoid damage to the connector and gage Tempe...

Page 12: ...faces we recommend using compressed air directing the air where it is needed through a plastic not metal nozzle If the compressed air does not remove the foreign material use a cotton swab or if the s...

Page 13: ...85059G 1 0 mm Connector Gage Operation Overview of Gage Features Figure 1 85059G Connector Gage Features 85059 60100 Female Gage Set 85059 60101 Male Gage Set Mode Set Data ON OFF Current Mode INC Cu...

Page 14: ...settings as required See also section 7 Functions and Operating Procedure in this doc ID C112X 1012X Refer to Figure 3 on page 17 If the battery holder is not set properly the instrument may not disp...

Page 15: ...m Connector Gage Operation Figure 2 Installing Changing the Battery Battery installed bottom view Battery case and battery before installing top view Battery case and battery before installing bottom...

Page 16: ...down arrow near the gage s displayed current mode H Hold mode If your gage is displaying H you will not be able to update change the display until you disable Hold mode Press the DATA button to enabl...

Page 17: ...d Setting INC Mode 1 Battery installed Display is flashing P is blinking No mode displayed I e Preset condition 2 SET button pressed 1st time Zeros are displayed and P is flashing 3 SET button pressed...

Page 18: ...ng nut to 45 N cm 4 lb in Push the SET button to zero the digital gage indicator Figure 4 on page 19 IMPORTANT Before you make a measurement verify the gage is not displaying Hold or REV Refer to Figu...

Page 19: ...be checked often to make sure that the zero setting has not changed Generally when the gage readout on a gage that has been recently zeroed does not display zero the gage or calibration block needs c...

Page 20: ...ode 2a Hold MODE button until dir direction is displayed and flashing 3 Press MODE button and down arrow disappears i e exited REV mode 2a Then press SET button Now the down arrow is flashing but dir...

Page 21: ...d tighten only the connecting nut do not turn the gage or the device until finger tight Recession or protrusion will show as a reading either a negative or positive reading from zero See Figure 1 on p...

Page 22: ...urn OFF the gage Press and hold the DATA ON OFF button for 2 seconds IMPORTANT The gage powers up in the previous Measurement mode that was set before power down Refer to Measurement Mode on page 16 I...

Page 23: ...nd Figure 8 on page 25 There are no internal replaceable parts within the Gages themselves Figure 7 85059G Connector Gage with Accessories 85059G with transit case 85059 60100 female gage with f maste...

Page 24: ...male 1 85059 60100 Gage set 1mm Male 1 85059 60101 Calibration Kit Storage Case Box with customized foam inserts 1 1540 2350 Wrenches 6 mm open end wrench 1 8710 2156 6 mm 45 N cm 4 in lb torque wrenc...

Page 25: ...r the 85059G Connector Gage Kit Not all items are shown below For a complete list refer to Table 4 on page 24 Service Do not attempt to repair the gage or gage master Any attempt to do so will void wa...

Page 26: ...26 Operating and Service Guide 85059 90015 85059G 1 0 mm Connector Gage Replaceable Parts...

Page 27: ...Installation Note Xxxxx xxxxx 3...

Page 28: ...This information is subject to change without notice Keysight Technologies 2018 2020 Edition 1 December 2020 www keysight com...