12
Keysight 11636A Operating and Service Manual
Dimensions:
Figure 2
Dimensions
Nominal insertion loss (Input to one output port): 6.0 dB (-0.2 dB, +1.2 dB maximum to 10.0 GHz;
+1.5 dB maximum to 18.0 GHz)
Typical phase tracking:
\
2
°
between output ports.
Power coefficient: <0.005 dB/dB/W
Temperature coefficient: <0.0004 dB/dB/
°
C
Adjustments
The 11636A power divider requires no electrical or mechanical adjustments.
Service
The circuit elements of the 11636A are split into three identical channels. A malfunction will usually
occur in only one channel and can be verified by moving the connection to another channel of the
divider.
An ohmmeter can be used to check the continuity of the inner conductor connections. The
resistance from either output center conductor to the input center conductor should be 33.3 ohms
+/– 2 ohms.
There are no replaceable components for the power divider. A worn or damaged power divider
must be replaced in whole.
Dimension A
Dimension B
Dimension C
Dimension D
(1.96) 0.77
(4.45) 1.75
(1.75) 0.69
(4.17) 1.64
NOTE:
Dimensions are
given in (cm) inches
and are maximum
unless otherwise
specified