Keysight 1158 Series Operating And Service Manual Download Page 22

22

Keysight 849x and 1158x Operating and Service Manual

Table 11

SWR verification

Attenuation (dB)

SWR meter range (dB)

Meter indication (dB)

Minimum

Actual

Maximum

0 (system cal)

2 (or 10)

[a]

[a] Set SWR meter range to 10 dB and power level to 0.0 dB for 3 dB, 6 dB, and 10 dB attenuators only.

Set to 0.5 (or 0.0)

[a]

3

10

1.35

1.65

6

12

0.85

1.15

10

14

0.75

1.25

20

12

0.25

0.75

30

16

1.00

2.00

40

22

-0.25

1.25

50

26

0.75

2.25

60

32

-0.50

1.50

Summary of Contents for 1158 Series

Page 1: ...Keysight 8490D G 8491A B 8493A B C Coaxial Fixed Attenuators Keysight 11581A 11582A 11583C Attenuator Sets Operating and Service Manual...

Page 2: ...hese rights customarily provided to the public to use modify reproduce release perform dis play or disclose commercial computer soft ware or commercial computer software documentation No additional go...

Page 3: ...or electronic product in domestic household waste Product category With reference to the equipment types in the WEEE directive Annex 1 this instrument is classified as a Monitoring and Control Instru...

Page 4: ...4 Keysight 849x and 1158x Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 5: ...ral Information 11 Attenuator overview 11 Features 11 Optional calibration data 12 Attenuator sets 12 Specifications 13 Environmental Specifications 19 Installation 20 Initial inspection 20 Returning...

Page 6: ...6 Keysight 849x and 1158x Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 7: ...ures Figure 1 Equipment setup using oscillator and SWR meter 21 Figure 2 Equipment setup using network analyzer 23 Figure 3 2 4 mm 1 85mm connector diagram 24 Figure 4 Type N connector diagram 25 Figu...

Page 8: ...8 Keysight 849x and 1158x Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 9: ...ttenuator 14 Table 5 Specifications for 8491A and 8493A coaxial fixed attenuators 15 Table 6 Specifications for 8491B and 8493B coaxial fixed attenuators 16 Table 7 Specifications for 8493C coaxial fi...

Page 10: ...10 Keysight 849x and 1158x Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 11: ...ations Accuracy and low SWRs make the attenuators well suited for extending the range of sensitive power meters for higher power measurements and applications such as calibration standards and RF subs...

Page 12: ...hnologies Service Centers Attenuator sets The 11581A 11582A and 11583C are boxed sets of four coaxial fixed attenuators of 3 6 10 and 20 dB as shown in Table 2 Each attenuator set comes with a printed...

Page 13: ...3 indicates 3 dB attenuation Option 010 indicates 10 dB attenuation and so on DC to 50 GHz DC to 26 5 GHz 26 5 to 50 GHz 003 2 5 3 9 4 8 006 5 4 6 9 7 8 010 9 4 10 9 11 3 020 19 2 21 3 21 7 030 29 2 3...

Page 14: ...1 5 31 7 040 38 0 42 5 42 5 42 5 Maximum SWR Option a a Option numbers indicate the attenuation values For example Option 003 indicates 3 dB attenuation Option 010 indicates 10 dB attenuation and so o...

Page 15: ...003 0 3 006 0 3 010 0 5 020 0 5 030 1 0 040 b b Options 040 050 and 060 are not available for 8493A 1 5 050 b 1 5 060 b 2 0 SWR Option a DC to 8 GHz 8 to 12 4 GHz 003 1 25 1 35 006 1 2 1 3 010 1 2 1 3...

Page 16: ...on 003 indicates 3 dB attenuation Option 010 indicates 10 dB attenuation and so on DC to 26 5 GHz 26 5 to 40 GHz 40 to 50 GHz 003 1 25 1 3 1 5 006 1 2 1 3 1 5 010 1 2 1 3 1 5 020 1 2 1 3 1 5 030 1 2 1...

Page 17: ...a DC to 18 GHz 18 to 26 5 GHz 003 0 5 1 0 006 0 6 0 6 010 0 3 0 5 020 0 5 0 6 030 0 7 1 0 040 1 0 1 3 SWR Option a a Option numbers indicate the attenuation values For example Option 003 indicates 3 d...

Page 18: ...ements S11 S22 Attenuation DC to 4 GHz 4 to 12 GHz 12 to 18 GHz 3 dB 0 01 dB 0 06 dB 0 11 dB 6 dB 0 01 dB 0 07 dB 0 11 dB 10 dB 0 01 dB 0 07 dB 0 12 dB 20 dB 0 01 dB 0 08 dB 0 13 dB Female Male Model...

Page 19: ...fully comply with Keysight Technologies product operating environmental specifications as shown Table 10 Table 10 849x coaxial fixed attenuator and 1158x attenuator sets environmental specifications T...

Page 20: ...ent Keep the shipping materials for the carrier s inspection 3 If you are returning the instrument under warranty or for service repackaging the instrument requires original shipping containers and ma...

Page 21: ...rocedure 1 Connect the equipment as shown in the Figure 1 except remove the attenuator and connect the adapters directly together Figure 1 Equipment setup using oscillator and SWR meter 1 Set the test...

Page 22: ...dB Meter indication dB Minimum Actual Maximum 0 system cal 2 or 10 a a Set SWR meter range to 10 dB and power level to 0 0 dB for 3 dB 6 dB and 10 dB attenuators only Set to 0 5 or 0 0 a 3 10 1 35 1 6...

Page 23: ...ports of the network analyzer This depends on the type of the attenuator being checked The equipment setup is as illustrated in Figure 2 1 Calibrate the network analyzer with appropriate settings and...

Page 24: ...d by other devices connected to them The attenuators are bidirectional that is the signal may be inserted from either end 8490D G The 8490D 2 4 mm connectors mate with other 2 4 mm connectors of the o...

Page 25: ...rvice Manual 25 8491A B The 8491A B type N connectors mate with all type N connectors whose dimensions conform to IEE STD 287 Figure 4 Type N connector diagram NOTE Do not mate with 0 071 inch diamete...

Page 26: ...49x and 1158x Operating and Service Manual 8493A B The 8493A B has a male SMA jack on one end and a female SMA on the other These connectors mate with the opposite sex SMA connectors Figure 5 SMA conn...

Page 27: ...3C has a male 3 5 mm connector on one end and a female 3 5 mm connector on the other side These connectors mate with the opposite sex 3 5 mm or SMA connectors Figure 6 3 5 mm connector diagram NOTE Co...

Page 28: ...ormance Test The attenuators can be tested to the accuracy of the specifications with a network analyzer or equivalent equipment of suitable accuracy If a network analyzer is available test the instru...

Page 29: ...ir since the cards must be mounted in cartridges to test and testing costs more than a replacement attenuator Maintenance The connectors particularly the connector faces must be kept clean This is esp...

Page 30: ...30 Keysight 849x and 1158x Operating and Service Manual THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...

Page 31: ...is subject to change without notice Always refer to the Keysight website for the latest revision Keysight Technologies 2014 2018 Edition 6 November 27 2018 Printed in Malaysia 08491 90077 08491 90077...

Reviews: