Single Unit Connections
Additional Load Considerations - all Models
Additional Load Considerations - RP793xA, RP794xA
Power Cable Connections
An AC mains power cable is not provided with the unit.
Refer to the following table for the maximum current capacity requirements for each cable conductor.
If required by local electrical codes, install a fuse or circuit breaker between the ac mains and the unit.
Refer to the following table for current ratings.
Keep the AC mains cables as short as possible. The longer the cable, the greater the voltage loss due
to cable resistance.
The cable cross-section must be suitable for the maximum input current of the
instrument. The ground cable must have the same cross-section as the phase cable.
Safety agency requirements dictate that there must be a way to physically disconnect
the AC mains cable from the unit. A disconnect device, either a switch or circuit breaker
must be provided in the final installation. The disconnect device must be close to the
equipment, be easily accessible, and be marked as the disconnect device for this
equipment. It must meet the input ratings requirements listed in the following table.
Model
Unit Rating
L1 Imax
L2 Imax
L3 Imax
RP7931A, RP7932A, RP7951A
5 kW - 200/208 VAC
19.5 A
19.5 A
19.5 A
RP7941A, RP7942A, RP7961A
5 kW - 400/480 VAC
9.5 A
9.5 A
9.5 A
RP7933A, RP7935A, RP7936A, RP7952A, RP7953A
10 kW - 200/208 VAC
39 A
39 A
39 A
RP7943A, RP7945A, , RP7946A, RP7962A, RP7963A
10 kW - 400/480 VAC
19 A
19 A
19 A
Either a delta-type or a Y-type AC mains distribution can be used, provided that the correct line-to-line
voltage is applied (see above). Do not connect the neutral wire on Y-type AC mains distribution. An
earth-ground to chassis-ground connection through a separate conductor must always be provided.