Table 2 

SAX Options 

Option

Description

DC9

Standard SAX with 9 VDC supply

UDC

Adds IF input data (on USB) for frequency up-conversion

D48

Adds data on USB down to 48 GHz (for N9029AV15 only)

D73

Adds data on USB down to 73 GHz (for N9029AV10 only)

Keysight N9030-90061

5

H50

DC9 SAX with high sensitivity

Summary of Contents for N9029AV01-V15

Page 1: ...User s Guide Keysight Technologies N9029AV01 V15 V1B V2B Signal Analyzer Frequency Extension Module and Accessories ...

Page 2: ...tware to U S government customers under its standard commercial license which is embodied in its End User License Agreement EULA a copy of which can be found at http www keysight com find sweula The license set forth in the EULA represents the exclusive authority by which the U S government may use modify distribute or disclose the Software The EULA and the license set forth therein does not requi...

Page 3: ...and excellent noise figure Refer to the VDI User s Guide included on the USB drive For more information see the Product Manual at http vadiodes com images Products SAX VDI 731_SAX_Product_Manual pdf The cables and power supply will be included with the module in the transport case Cutouts have been created for the accessories within the transport case simply remove the foam insert Accessories avai...

Page 4: ...9029AV02 WR2 2SAX 325 to 500 N9029AV03 WR3 4SAX 220 to 330 N9029AV05 WR5 1SAX 140 to 220 N9029AV06 WR6 5SAX 110 to 170 N9029AV08 WR8 0SAX 90 to 140 N9029AV10 WR10SAX 75 to 110 N9029AV12 WR12SAX 60 to 90 N9029AV15 WR15SAX 50 to 75 N9029AV04 WR4 3SAX 170 to 260 Be aware of the power level applied to the waveguide input Non warrantied damage to the internal mixer can occur if the power level is at or...

Page 5: ...ard SAX with 9 VDC supply UDC Adds IF input data on USB for frequency up conversion D48 Adds data on USB down to 48 GHz for N9029AV15 only D73 Adds data on USB down to 73 GHz for N9029AV10 only Keysight N9030 90061 5 H50 DC9 SAX with high sensitivity ...

Page 6: ...F1 N9029AV12 BF2 N9029AV12 BF3 N9029AV12 BF4 N9029AV12 SW2 N9029AV15 BF1 N9029AV15 BF2 N9029AV15 BF3 N9029AV15 BF4 N9029AV15 BF5 N9029AV15 BF6 Bandpass Filter 59 5 61 GHz WR12 Bandpass Filter 71 76 GHz WR12 Bandpass Filter 81 86 GHz WR12 Bandpass Filter 76 81 GHz WR12 WR12 Waveguide 2 In Straight Section from VDI Bandpass Filter 57 2 59 4 GHz WR15 Bandpass Filter 59 4 61 6 GHz WR15 Bandpass Filter...

Page 7: ...monic and Doubler Switched parameters For the N90x0A Models Input Output External Mixer External Mixer Ext Mix Setup Edit Harmonic Table Enter or select OK Table Type Doubler Switching Harmonic N Enter N value see SAX label on module or see VDI document for N value For the N90x0B Models Input Output Select Input External Mixer External Mixer Setup Table Type Doubler Switching Harmonic under Harmon...

Page 8: ... multiplication factor of the LO input H IF input N x LO input H IF input waveguide output frequency Refer to the VDI User s Guide for frequencies and power levels 1 Connect RF source to LO input H such as an E8257D PSG 2 Connect RF signal to be up converted to the IF input such as an E8257D PSG Voltage Bias Port LO input H IF input Other modes of operation may be found in the VDI documentation 8 ...

Page 9: ...he product The CE mark is a registered trademark of the European Community The Keysight email address s required by EU directives applicable to our product This is a symbol of an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 5 This is a marking to indicate product compliance with the Canadian Interference Causing Equipment Standard ICES 001 Cet appareil ISM est conforme...

Page 10: ...esidential environment this equipment may cause radio interference This EMC statement applies to the equipment only for use in a business environment 사 용 자 안 내 문 이 기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은 기기로서 가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다 사용자 안내문은 업무용 방송통신기자재 에만 적용한다 This is a sensitive measurement apparatus by design and may have some performance loss spurs up to 55 dB above a noise floor when exposed ...

Page 11: ...ve been checked mechanically and electrically If there is mechanical damage or if the instrument does not pass the performance tests notify the nearest Keysight Technologies office Keep the damaged shipping materials if any for inspection by the carrier and a Keysight Technologies representative Contacting Keysight Assistance with test and measurement needs and information on finding a local Keysi...

Page 12: ...This information is subject to change without notice Keysight Technologies 2016 2019 Print Date January 2019 Supersedes March 2018 www keysight com ...

Reviews: