282
Keysight N5990A MIPI M-PHY Receiver Test User Guide
8
Sys Burst Tests
is measured using a real time oscilloscope. Among all measured
T
TERM-OFF-SYS-RX
values, the maximum and minimum T
TERM-OFF-SYS-RX
values are considered as the final results.
The test will pass if the maximum T
TERM-OFF-SYS-RX
value measured is less
than the time defined by the DUT's Sleep Time capability attribute.
This test is performed at each selected lane and PWM gear and it is tested
at the minimum and maximum data rate value for all gears.
Connection Diagram
Refer to the connection diagrams shown in the Connection Diagram
section of the Test 2.1.4-HS-RX Differential Termination Enable Time test.
Parameters
The parameters used in
Expert Mode
for this test, are as follows:
• CDR Loop Bandwidth (if CDR is selected in the Special Parameter
dialog, see
)
• CDR Peaking (if CDR is selected in the Special Parameter dialog, see
• CDR Transition Density (if CDR is selected in the Special Parameter
dialog, see
)
• CDR Loop Order (if CDR is selected in the Special Parameter dialog,
see
• Set Single Ended Amplitude
• Set Offset
• Prepare Length
• Sleep Length
• Sleep Time Capability
• Test Sequence
• IBerReader Init Mode
• Lane Under Test Termination Model
These parameters are listed in alphabetical order in
Dependencies
The calibrations required for this test are as follows:
• Reference Clock Calibration
• Level Calibration Terminated / Into Open
Summary of Contents for N5990A
Page 1: ...User Guide Keysight N5990A MIPI M PHY Receiver Test...
Page 62: ......
Page 86: ...86 Keysight N5990A MIPI M PHY Receiver Test User Guide 4 Calibrations...
Page 88: ...88 Keysight N5990A MIPI M PHY Receiver Test User Guide 4 Calibrations...
Page 214: ......
Page 234: ......
Page 268: ......
Page 298: ......