Keysight N5990A MIPI M-PHY Receiver Test User Guide
239
PWM Tests
7
Table 40
Test 2.2.1-PWM-RX Differential Input Voltage Amplitude Test data table
Parameter Name
Parameter Description
Result
"Pass"/"Fail" - If the value is "Fail", the amplitude tolerance value is below the spec limits.
PWM Data Rate
It is the PWM data rate value in MBit/s.
Min Spec
It is value of the amplitude that is tested.
Offset
It is the offset value that is tested.
Min Passed Amplitude
It is the minimum amplitude value, where the DUT works successfully.
Min Spec Amplitude
It is the minimum amplitude value, where the DUT must work without error.
Max Passed Amplitude
It is the maximum value of amplitude, where the DUT works successfully.
Max Spec Amplitude
It is the maximum amplitude value, where the DUT must work without any error.
Error Count
The number of errors that occurred during the test.