Specifications

Table 2

 lists out the specifications for various characteristics of the N4891A chassis.

Table 2

N4891A Specifications

Device Characteristics

Specification values

Physical Interfaces

Native QSFP-DD MSA compatible physical ports

Chassis Configurations

2- or 4-port base chassis system, desktop or rack mount, 2 RU

Chassis Connector Systems

Power ON/OFF button
1 LED per port
Clock IN / OUT: 2 SMA female connectors
Trigger IN / OUT: 2 SMA female connectors
4 USB: (2) USB 2.0 (2) USB 3.0 compatible ports
1 RJ45: 1000/100/10Mbps Ethernet management port
1 Display Port, supports a maximum resolution of 4096 x 2304 @60Hz

Chassis Clock IN – Electrical Specifications

Frequency: 166.015625 MHz +/- 100 PPM
50 ohm termination
Minimum = 0.5 Vpk-pk = 0.18 Vrms (sine)
Maximum = 3.0 Vpk-pk = 1.06 Vrms (sine)

Chassis Clock OUT – Electrical Specifications

Frequency: 166.015625 MHz +/- 100 PPM
HCSL, 50 Ohm
VOH > 0.55V, VOL < 0.15V, Swing > 0.55V

Hardware Trigger IN / OUT – Electrical 
Specifications

Trigger In: 50 ohm termination; Minimum = -1.0V, Maximum = +4.0V, Swing > 0.2V
Trigger Out: HCSL, 50 ohm; VOH > 0.55V, VOL < 0.15V, Swing > 0.55V

Chassis System Electrical Power

Operates on 100-240VAC, 50/60Hz,

8 Amps on 100-125VAC

4 Amps on single phase, 200-240VAC

Chassis System Dimensions

11.14” (L) x 17.4” (W) x 3.65” (H)
283mm (L) x 442mm (W) x 92.65mm (H)

Chassis System Weights

Hardware only: 21.75 lbs. (9.87 kg)
Shipping: 30.49 lbs. (13.83 kg)
Includes rack mount ears, cable support bracket, power cord, accessories and packaging.

Temperature

Operating: 41°F to 95°F (5°C to 35°C)
Storage: 41°F to 122°F (5°C to 50°C)

Humidity

Operating: 0% to 85%, non-condensing
Storage: 0% to 85%, non-condensing

Regulatory Compliance Specifications

IEC 60950-1, UL 60950-1, CSA C22.2 No.60950-1, IEC 62368-1, UL 62368-1,
CSA 62368-1, CE (LVD, EMC, RoHS), EN/IEC 55032, EN/IEC 55024, CFR 47, FCC Part 15B, ICES-003, AS/NZ CISPR 
32/24, KN32/35

Summary of Contents for N4891A

Page 1: ...Keysight N4891A 400GBASE FEC Aware Rx Test Solution Getting Started...

Page 2: ...tion No additional government requirements beyond those set forth in the EULA shall apply except to the extent that those terms rights or licenses are explicitly required from all providers of commerc...

Page 3: ...he N4891A Solution 7 N4891A 400G Multi Port Tester 7 N4891A 400GBASE FEC aware Receiver Test Solution 7 Specifications 8 2 Getting Started with the N4891A Solution Chassis Setup 10 Installing the N489...

Page 4: ...4 Keysight N4891A 400GBASE FEC Aware Rx Test Solution Getting Started Guide Contents...

Page 5: ...Keysight N4891A 400GBASE FEC Aware Rx Test Solution Getting Started Guide 1 Introduction Safety Issues 6 Introduction to the N4891A Solution 7 Specifications 8...

Page 6: ...nt from Coaxial Cables Connect the shield coaxial cables to building earth in accordance with applicable local national and international electrical codes Fan Instruction Moving fan blade Keep body pa...

Page 7: ...r 1 BERT 400GE test software A browser based user interface makes it easy to run tests and manage the N4891A equipment Keysight N4891A and Ixia A400GE QDD offer the same capabilities and are interchan...

Page 8: ...pk pk 1 06 Vrms sine Chassis Clock OUT Electrical Specifications Frequency 166 015625 MHz 100 PPM HCSL 50 Ohm VOH 0 55V VOL 0 15V Swing 0 55V Hardware Trigger IN OUT Electrical Specifications Trigger...

Page 9: ...ight N4891A 400GBASE FEC Aware Rx Test Solution Getting Started Guide 2 Getting Started with the N4891A Solution Chassis Setup 10 Front Panel Overview 12 Controlling the Equipment 13 Installing Licens...

Page 10: ...tach the mounting ears and then insert the N4891A chassis into the rack 3 Connect the N4891A s management port to a network and obtain an IP address 4 Activate the license for the N4891A 5 Connect the...

Page 11: ...tarted with the N4891A Solution 2 Bench mounting To mount the N4891A chassis in a rack refer to Figure 2 1 Install the mounting ears one at each corner 2 Insert the N4891A chassis into the rack and fa...

Page 12: ...rview The N4891A front panel includes the following components Power ON OFF button 1 link activity LED per port Clock in out 2 SMA female connectors Trigger in out 2 SMA female connectors 4 USB 2 USB...

Page 13: ...ess to a USB flash drive inserted into any of the USB ports DisplayPort method 1 With the N4891A chassis powered off connect one end of an Ethernet cable to the management port of the chassis and conn...

Page 14: ...connect the other end to a switch port that has access to a network that includes a DHCP server 2 Power on the N4891A chassis 3 Launch a terminal window to the N4891A chassis 4 Use the following comma...

Page 15: ...Keysight N4891A 400GBASE FEC Aware Rx Test Solution Getting Started Guide 15 Getting Started with the N4891A Solution 2 Figure 4 Connection diagram sample for the N4891 solution...

Page 16: ...1A chassis is on open a browser window and enter the IP address into the URL field The KiOS software landing page is displayed 3 In the Settings menu select Settings License The License Manager page i...

Page 17: ...on Table 3 License Manager fields and description License Manager field Description Feature Feature enabled after installing the license Description Description of the licensed feature Version Version...

Page 18: ...n 18 Keysight N4891A 400GBASE FEC Aware Rx Test Solution Getting Started Guide NOTE For more information regarding the functionality and usage of the N4891A solution refer to the Keysight N4891A 400GB...

Page 19: ...Keysight N4891A 400GBASE FEC Aware Rx Test Solution Getting Started Guide 19...

Page 20: ...This information is subject to change without notice Keysight Technologies 2020 March 2020 www keysight com...

Reviews: