background image

When fuses are used in a product, replace 
with the same type and rating for 
continued protection against fire hazard.

Chassis connections must only be used as 
shield connections for measuring circuits, 
NOT as safety earth ground connections.

If you are using a test fixture, keep the lid 
closed while power is applied to the 
device under test. Safe operation requires 
the use of a lid interlock.

Instrumentation and accessories shall not 
be connected to humans.

Before performing any maintenance, 
disconnect the line cord and all test 
cables.

To maintain protection from electric shock 
and fire, replacement components in 
mains circuits - including the power 
transformer, test leads, and input jacks - 
must be purchased from Keysight. 
Standard fuses with applicable national 
safety approvals may be used if the rating 
and type are the same. Other components 
that are not safety related may be 
purchased from other suppliers as long as 
they are equivalent to the original 
component (note that selected parts 
should be purchased only through 
Keysight to maintain accuracy and 
functionality of the product). If you are 
unsure about the applicability of a 
replacement component, call an Keysight 
office for information.

No operator serviceable parts inside.Refer 
servicing to qualified personnel. To 
prevent electrical shock do not remove 
covers. For continued protection against 
fire hazard, replace fuse with same type 
and rating.

PRODUCT MARKINGS:

The CE mark is a registered trademark of 
the European Community.

Australian Communication and Media 
Authority mark to indicate regulatory 
compliance as a registered supplier.

This symbol indicates product compliance 
with the Canadian Interference-Causing 
Equipment Standard (ICES-001). It also 
identifies the product is an Industrial 
Scientific and Medical Group 1 Class A 
product (CISPR 11, Clause 4).

South Korean Class A EMC Declaration. This 
equipment is Class A suitable for 
professional use and is for use in 
electromagnetic environments outside of the 
home.

 

This product complies with the WEEE 
Directive marketing requirement. The affixed 
product label (above) indicates that you 
must not discard this electrical/electronic 
product in domestic household waste. 
Product Category: With reference to the 
equipment types in the WEEE directive 
Annex 1, this product is classified as 
“Monitoring and Control instrumentation” 
product. Do not dispose in domestic 
household waste. To return unwanted 
products, contact your local Keysight office, 
or for more information see 

http://about.

keysight.com/en/companyinfo/environment
/takeback.shtml

This symbol indicates the instrument is 
sensitive to electrostatic discharge (ESD). 
ESD can damage the highly sensitive 
components in your instrument. ESD 
damage is most likely to occur as the 
module is being installed or when cables 
are connected or disconnected. Protect 
the circuits from ESD damage by wearing 
a grounding strap that provides a high 
resistance path to ground. Alternatively, 
ground yourself to discharge any builtup 
static charge by touching the outer shell 
of any grounded instrument chassis 
before touching the port connectors.

This symbol on an instrument means 
caution, risk of danger. You should refer 
to the operating instructions located in 
the user documentation in all cases where 
the symbol is marked on the instrument.

This symbol indicates the time period 
during which no hazardous or toxic 
substance elements are expected to leak 
or deteriorate during normal use. Forty 
years is the expected useful life of the 
product.

Summary of Contents for M9451A

Page 1: ...Keysight M9451A PXIe Measurement Accelerator Startup guide...

Page 2: ...are under the same terms by which the software is customarily provided to the public Accordingly Keysight provides the Software to U S government customers under its standard commercial license which...

Page 3: ...often associated with local AC mains connections Assume all measurement control and data I O connections are for connection to Category I sources unless otherwise marked or described in the user docu...

Page 4: ...the Canadian Interference Causing Equipment Standard ICES 001 It also identifies the product is an Industrial Scientific and Medical Group 1 Class A product CISPR 11 Clause 4 South Korean Class A EMC...

Page 5: ...ments 16 Chassis Requirements 17 M9018A Chassis Air Flow 17 Power up the Controller 18 Software Installation Overview 18 Software Installation Procedure 19 Step 4 Install the Module 20 Module Installa...

Page 6: ...Keysight M9451A PXIe Measurement Accelerator 6...

Page 7: ...Keysight M9451A PXIe Measurement Accelerator 7 Documentation Access...

Page 8: ...amplifiers PAs and front end modules FEMs Hardware acceleration provides speed improvement over Keysight s previous host based Reference Solution with closed open loop digital pre distortion DPD and...

Page 9: ...e is designed to work with the Keysight s RF PA FEM Characterization Test Reference Solution and allows you to perform fast DPD ET measurements with hardware that supports peer to peer transfers For m...

Page 10: ...ocumentation To access documentation related to the Keysight M9451A PXIe Measurement Accelerator use one of the following methods If the product software is installed on your PC the related documents...

Page 11: ...ns as well as information to help you get started with using the IVI drivers in your application development environment Your Drive Program Files x86 IVI Foundation IVI Drivers KtMMAcc KtMMAcc chm CHM...

Page 12: ...asurement Accelerator 12 To find the very latest versions of the user documentation go to the product web site and download the files from the www keysight com find m9451a Manuals support page go to D...

Page 13: ...wrist strap combination and conductive floor mat and heel strap combination Both types when used together provide a significant level of ESD protection Of the two only the table mat and wrist strap co...

Page 14: ...h it to the malfunctioning equipment Name and address of owner A P O box is not acceptable as a return address Module serial number s The serial number label is located on the side panel of the module...

Page 15: ...rs this functionality through propriety APIs and does not allow the customer to reprogram the FPGA with a custom image Items included in your Shipment Qty Keysight Part Number Description 1 M9451A Key...

Page 16: ...ble hard disk space includes 1 GB available for Microsoft NET Framework 3 5 SP1 100 MB for Keysight IO Libraries Suite Video Support for DirectX 9 graphics with 128 MB graphics memory recommended Supe...

Page 17: ...perable or forced air cooling is obstructed Use slot blockers Keysight model 5 per kit and EMC filler panels in Y1212A empty module slots to ensure proper operating temperatures Keysight chassis and s...

Page 18: ...e chassis The Keysight M9036A PXIe Embedded Controller and Keysight M9018A PXIe Chassis are recommended Please refer to the embedded controller and chassis documentation for further details Connect pe...

Page 19: ...you to choose either a complete or custom setup to install Choose the features to install and click Next Follow the guided tour to complete the installation Click Next After the installation complete...

Page 20: ...n speed settings ensure that the fan switch is set appropriately for the system Default setting is AUTO fan speed and the inhibit set to DEF Position the chassis to provide ample space between the cha...

Page 21: ...is Secure the module to the chassis using the module mounting screws Use a 1 Pozidriv or a slotted screwdriver and torque to 5 Lb In 0 57 N m Performance may suffer if the screws are not tightened pro...

Page 22: ...sing an external host PC If all the modules and their slot locations are not visible in the Connect to Instrument dialog of SFP program Close the SFP Start Keysight Connection Expert by selecting Star...

Page 23: ...en the M9451A SFP by selecting Start All Programs Keysight MMAcc MMAcc SFP Select the M9451A module in the dialog and Connect to Instrument click to initialize the instrument Connect Check the front p...

Page 24: ...Accelerator the LED starts in the OFF state and then changes to green after a few moments when PXI enumeration has taken place Generally when the LED status is solid green or solid blue it means that...

Page 25: ...LED color Description Blue blinking The accelerator is processing data or a self test is running Yellow solid An error or self test failure occurred Red solid Error condition Analog power supply shut...

Page 26: ...the most important consideration in comparing IVI COM and IVI C drivers is the end user experience in various ADEs Since IVI COM drivers are based on Microsoft COM technology it s not surprising that...

Page 27: ...r further troubleshooting information Contact a Keysight Technologies Service Center Computer Verify that the equipment meets the minimum requirements Refer Software Requirements Refer to the computer...

Page 28: ...ted User A user with Administrator status can reset the permissions of a Restricted User to enable that user to run the software The following steps outline the procedure In Windows Explorer navigate...

Page 29: ...This information is subject to change without notice Keysight Technologies 2013 2015 Edition 1 1 July 2015 Printed In Malaysia M9451 90001 M9451 90001 www keysight com...

Reviews: