Keysight Technologies M8195A Getting Started Manual Download Page 2

Notices

 

Copyright Notice 

© Keysight Technologies 201

7

 

No part of this manual may be repro- 
duced in any form or by any means 
(including electronic storage and retrieval 
or translation into a foreign language) 
without prior agreement and written con- 
sent from Keysight Technologies, Inc. as 
governed by United States and interna- 
tional copyright laws. 

Manual Part Number 

M8195-91030 

Edition 

Edition 

3

.0, 

October

 201

7

 

Printed in: 

Printed in Malaysia 

Published by: 

Keysight Technologies 
Deutschland GmbH, 
Herrenberger Str. 130, 
71034 Böblingen, Germany 

Technology Licenses 

The hardware and/or software described 
in this document are furnished under a 
license and may be used or copied only 
in accordance with the terms of such 
license. 

ESD Sensitive Device 

All front-panel connectors of the 
M8195A are sensitive to Electrostatic 
discharge (ESD). We recommend to 
operate the instrument in an 
electrostatic safe environment.  

There is a risk of instrument malfunction 
when touching a connector.  

Please follow this instruction: 

Before touching the front-panel 
connectors, discharge yourself by 
touching the properly grounded 
mainframe. 

U.S. Government 
Rights 

The Software is “commercial computer 
software,” as defined by Federal Acquisi- 
tion Regulation (“FAR”) 2.101. Pursuant 
to FAR 12.212 and 27.405-3 and Depart- 
ment of Defense FAR Supplement 
(“DFARS”) 227.7202, the U.S. govern- 
ment acquires commercial computer 
software under the same terms by which 
the software is customarily provided to 
the public. Accordingly, Keysight pro- 
vides the Software to U.S. government 
customers under its standard commercial 
license, which is embodied in its End 
User License Agreement (EULA), a copy 
of which can be found a

http:// 

www.keysight.com/find/sweula

The li- 

cense set forth in the EULA represents 
the exclusive authority by which the U.S. 
government may use, modify, distribute, 
or disclose the Software. The EULA and 
the license set forth therein, does not 
require or permit, among other things, 
that Keysight: (1) Furnish technical infor- 
mation related to commercial computer 
software or commercial computer soft- 
ware documentation that is not custom- 
arily provided to the public; or (2) Relin- 
quish to, or otherwise provide, the  gov- 
ernment rights in excess of these rights 
customarily provided to the public to use, 
modify, reproduce, release, perform, dis- 
play, or disclose commercial computer 
software or commercial computer soft- 
ware documentation. No additional gov- 
ernment requirements beyond those set 
forth in the EULA shall apply, except to 
the extent that those terms, rights, or 
licenses are explicitly required from all 
providers of commercial computer soft- 
ware pursuant to the FAR and the DFARS 
and are set forth specifically in writing 
elsewhere in the EULA. Keysight shall be 
under no obligation to update, revise or 
otherwise modify the Software.  With 
respect to any technical data as defined 
by FAR 2.101, pursuant to FAR 12.211 
and 27.404.2 and DFARS 227.7102, the 
U.S. government acquires no greater 
than Limited Rights as defined in FAR 
27.401 or DFAR 227.7103-5 (c), as appli- 
cable in any technical data. 

Warranty 

THE MATERIAL CONTAINED IN THIS 
DOCUMENT IS PROVIDED “AS IS,” 
AND IS SUBJECT TO BEING 
CHANGED, WITHOUT NOTICE, IN 
FUTURE EDITIONS. FURTHER, TO 
THE MAXIMUM EXTENT PERMITTED 
BY APPLICABLE LAW, KEYSIGHT 
DISCLAIMS ALL WARRANTIES, EI- 
THER EXPRESS OR IMPLIED, WITH 
REGARD TO THIS MANUAL AND 
ANY INFORMATION CONTAINED 
HEREIN, INCLUDING BUT NOT LIM- 
ITED TO THE IMPLIED WARRANTIES 
OF MERCHANTABILITY AND FIT- 
NESS FOR A PARTICULAR PUR- 
POSE. KEYSIGHT SHALL NOT BE 
LIABLE FOR ERRORS OR FOR INCI- 
DENTAL OR CONSEQUENTIAL DAM- 
AGES IN CONNECTION WITH THE 
FURNISHING, USE, OR PERFOR- 
MANCE OF THIS DOCUMENT OR OF 
ANY INFORMATION CONTAINED 
HEREIN. SHOULD KEYSIGHT AND 
THE USER HAVE A SEPARATE 
WRITTEN AGREEMENT WITH WAR- 
RANTY TERMS COVERING THE MA- 
TERIAL IN THIS DOCUMENT THAT 
CONFLICT WITH THESE TERMS, 
THE WARRANTY TERMS IN THE 
SEPARATE  AGREEMENT  SHALL 
CONTROL. 

Safety Information 

A CAUTION notice denotes a hazard. 
It calls attention to an operating 
procedure, practice, or the like that, 
if not correctly performed or adhered 
to, could result in damage to the 
product or loss of important data. Do 
not proceed beyond a CAUTION 
notice until the indicated conditions 
are fully understood and met

A WARNING notice denotes a haz- 
ard. It calls attention to an operating 
procedure, practice, or the like that, 
if not correctly performed or adhered 
to, could result in personal injury or 
death. Do not proceed beyond a 
WARNING notice until the indicated 
conditions are fully understood and 
met. 

CAUTION

 

WARNING

 

Summary of Contents for M8195A

Page 1: ...Getting Started Guide Keysight M8195A Arbitrary Waveform Generator Revision 2...

Page 2: ...ide the gov ernment rights in excess of these rights customarily provided to the public to use modify reproduce release perform dis play or disclose commercial computer software or commercial computer...

Page 3: ...ervice Office WARNING To avoid hazardous electrical shock do not perform electrical tests when there are signs of shipping damage to any portion of the outer enclosure covers panels etc General This p...

Page 4: ...Recycling Mark Table 2 Compliance and Environmental Information Symbol Description This product complies with the WEEE Directive 2002 96 EC marketing requirements The affixed label indicates that you...

Page 5: ...ion Process 12 2 3 Post Installation Steps 21 2 4 How to use the Instrument 22 3 AXle Chassis 3 1 ESM Front Panel Connector 23 4 M8195A Maintenance 4 1 ESD Protection 26 4 2 Power and Ventilation Requ...

Page 6: ......

Page 7: ...2 independent I Q baseband signals dual polarization 4 channels at up to 32 Gbaud and beyond Multi level Multi channel digital signals generate NRZ PAM4 PAM8 DMT etc signals at up to 32 Gbaud Embed D...

Page 8: ...ach channel Analog bandwidth 20 GHz Vertical resolution 8 bits 1 2 or 4 differential channels per 1 slot high AXIe module number of channels is software upgradable Built in frequency and phase respons...

Page 9: ...simply requires a USB cable There are two different ordering possibilities M8195A AWG AXIe chassis PCIe cable PCIe adapter card and PC are ordered separately The different components come in differen...

Page 10: ...d documentation http www keysight com find M9505A for 5 slot chassis related documentation http www keysight com find M9502A for 2 slot chassis related documentation http www keysight com find M9048A...

Page 11: ...bit or 64 bit Windows 8 32 bit or 64 bit Windows 7 32 bit or 64 bit Ensure that you have Keysight IO Libraries Suite Version 16 3 or higher installed on your system The Keysight IO Libraries Suite ca...

Page 12: ...r system 1 Double click the executable M8195_Setup exe This executable file is available either on CD or Web The installer will first check and list some pre requisites Click Install to install them Y...

Page 13: ...M8195A Software Installation 2 Keysight M8195A Revision 2 Arbitrary Waveform Generator Getting Started Guide 13 3 Click Next...

Page 14: ...Arbitrary Waveform Generator Getting Started Guide 4 We recommend you to read the document to check if your hardware configuration is supported Click Next to proceed to the license agreements 5 Accep...

Page 15: ...M8195A Software Installation 2 Keysight M8195A Revision 2 Arbitrary Waveform Generator Getting Started Guide 15 6 Click Next 7 Accept the Keysight IVI Driver Source Code License Agreement Terms...

Page 16: ...tware Installation 16 Keysight M8195A Revision 2 Arbitrary Waveform Generator Getting Started Guide 8 Click Next 9 Select Yes if you want to read the post installation instructions Click Next to selec...

Page 17: ...allation 2 Keysight M8195A Revision 2 Arbitrary Waveform Generator Getting Started Guide 17 10 Select a setup type either Complete or Custom If you select Custom you can specify which optional feature...

Page 18: ...lation 18 Keysight M8195A Revision 2 Arbitrary Waveform Generator Getting Started Guide 11 Click Next 12 Click Install to begin the installation The Setup Wizard will now install M8195 beginning with...

Page 19: ...A Revision 2 Arbitrary Waveform Generator Getting Started Guide 19 13 The Keysight M8195A will configure the new software installation 14 The following screen will appear once the Keysight M8195A soft...

Page 20: ...evision 2 Arbitrary Waveform Generator Getting Started Guide 15 Click Finish to restart your system Do not connect the AXIe chassis to your system using the PCIe or USB cable during this reboot This c...

Page 21: ...nager or right click Computer Manage Device Manager In case of PCIe The instrument should be visible in the device tree as Agilent Technologies Modular Devices M8195A In case of USB The instrument sho...

Page 22: ...ght M8195 Keysight M8195 Soft Front Panel The user interface will display the VISA resource strings for different kinds of connection 3 Using the appropriate VISA resource string you can Start the Sof...

Page 23: ...he usage of the AXIe chassis in combination with the M8195A The detailed documentation for the AXIe chassis can be found at http www keysight com find M9514A for 13 slot chassis http www keysight com...

Page 24: ...daisy chained chassis 4 Multiframe Output 5 Trigger In External Trigger connections The Trigger In of the AXIe ESM cannot be used to trigger the M8195A The M8195A has its own Trigger In The Trigger Ou...

Page 25: ......

Page 26: ...very sensitive to electrostatic discharge ESD When you connect a device or cable that is not fully discharged to these connectors you risk damage to the instrument and expensive instrument repairs Ele...

Page 27: ...y 80 C the power supply is switched off The instrument will not turn on automatically if the temperature is decreasing again Fan Failure If a fan is broken or prevented from operating by a blockage th...

Page 28: ......

Page 29: ...40 C to 70 C Operating Temperature 0 C to 40 C Operating Humidity 5 to 80 relative humidity non condensing Operating Altitude Up to 2000 m Installation Category II Pollution Degree 2 5 3 General Powe...