222
Keysight InfiniiVision M9241/42/43A PXIe Oscilloscopes SCPI Programmer's Guide
7
Root (:) Commands
:HWERegister[:EVENt] (Hardware Event Event Register)
Query Syntax
:HWERegister[:EVENt]?
The :HWERegister[:EVENt]? query returns the integer value contained in the
Hardware Event Event Register.
Return Format
<value><NL>
<value> ::= integer in NR1 format.
See Also
•
"Introduction to Root (:) Commands"
•
•
":OPEE (Operation Status Enable Register)"
•
":OPERegister:CONDition (Operation Status Condition Register)"
•
":OVLenable (Overload Event Enable Register)"
•
":OVLRegister (Overload Event Register)"
•
•
"*SRE (Service Request Enable)"
To HWE bit in
Operation Status
Condition Register
OR
:HWERegister:CONDition?
Hardware Event Condition Register
:HWEenable
:HWEenable?
Hardware Event Enable (Mask) Register
1
0
2
3
4
5
6
7
9
8
10
11
12
13
14
15
:HWERegister[:EVENt]?
Hardware Event Event Register
PLL
Locked
PLL
Locked
12
Table 75
Hardware Event Event Register
Bit
Name
Description
When Set (1 = High = True), Indicates:
15-13
---
---
(Not used.)
12
PLL
Locked
PLL Locked
This bit is for internal use and is not intended for
general use.
11-0
---
---
(Not used.)