Measurement Operations & Settings
4
Table 9
Generating Output Triggers from Power Measurements
Hard ware
Triggering
Trigger Rearming
Software Triggering
Data Acquisition Functions
sens:func:stat
trig:outp
trig:outp:rearm
init:imm
init:cont
MINMax
LOGGing|STABility
DISabled
-
An output trigger will never be generated.
AVGover
ON
An output trigger is generated for every new power measurement when the averaging time period
finishes.
Applies for all subsequent data
acquisition functions.
MEASure
ON
An output trigger is generated for every new power measurement when the averaging time period begins.
Applies for all subsequent data
acquisition functions.
AVGover
OFF
An output trigger is generated when the averaging time period of
the first power measurement finishes. A further hardware output
trigger cannot be generated until you send trig:outp:rearm.
An output trigger is generated for
every new power measurement
when the averaging time period
finishes. Applies for all subsequent
data acquisition functions.
MEASure
OFF
An output trigger is generated when the averaging time period of
the first power measurement begins. A further hardware output
trigger cannot be generated until you send trig:outp:rearm.
An output trigger is generated for
every new power measurement
when the averaging time period
begins. Applies for all subsequent
data acquisition functions.
command:
:TRIGger
syntax:
:TRIGger<wsp>NODEA|1|NODEB|2
description:
Generates a hardware trigger.
parameters:
1 or NODEA:
2 or NODEB:
Is identical to a trigger at the Input Trigger Connector.
Generates trigger at the Output Trigger Connector.
A hardware trigger cannot be effective in the DISabled triggering mode but can be effective in DEFault, PASSthrough or
LOOPback triggering modes, see
on page 214 for information on triggering modes.