background image

T

able

3-3.

Replaceable

P

arts

List

(Misc.)

Reference

Designator

Agilent

P

art

Number

Qty

.

Description

35

16453-01213

1

Angle

Plate

36

16453-60021

1

Load

1

37

8710-2081

1

Tweezers

0

16453-60011

1

Carrying

Case

2

0

16453-90000

1

Specication

and

Service

Manual

2

1

Consists

of

load

plate

,

case

,

and

thickness

label.

2

These

parts

are

not

shown

in

this

gure

.

P

arts

Replacement

Procedures

This

section

provides

removal

and

replacement

procedures

for

the

16453A .

Note

In

this

section,

numbers

quoted

by

\"

correspond

to

Reference

Designators

in

the

Replaceable

P

arts

Lists

(T

able

3-1,

T

able

3-2,

and

T

able

3-3 ).

Removal

Procedure

Cover

Removal

1.

Release

latch

button

\17"

by

pulling

up

knob

\11"

if

it

is

latched.

2.

Remove

two

screws

\10"

on

the

sides

of

cover

\9."

3.

Loosen

screw

\14"

on

the

back

of

the

main

assembly

until

the

button

can

be

pushed

into

the

cover

.

4.

Remove

cover

\9"

carefully

while

preventing

the

button

from

popping

out.

3-4

Service

Summary of Contents for 16453A

Page 1: ...Keysight 16453A Dielectric Material Test Fixture Specification and Service Manual...

Page 2: ......

Page 3: ...Agilent 16453A Dielectric Material Test Fixture Speci cation and Service Manual Agilent Part No 16453 90010 Printed in JAP AN September 2000 Fourth Edition...

Page 4: ...copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of the Agilent Technologies Agilent Techno...

Page 5: ...and updates that are incorporated at reprint do not cause the date to change The manual part number changes when extensive technical changes are incorporated January 1994 First Edition part number 164...

Page 6: ...ges may exist even with the power cable removed To avoid injuries always disconnect power and discharge circuits before touching them DO NOT Service Or Adjust Alone Do not attempt internal service or...

Page 7: ...ution s calibration facility or to the calibration facilities of other International Standards Organization members Warranty This Agilent Technologies instrument product is warranted against defects i...

Page 8: ...the implied warranties of merchantability and tness for a particular purpose Exclusive Remedies The remedies provided herein are buyer s sole and exclusive remedies Agilent Technologies shall not be...

Page 9: ...f fault A terminal marked with this symbol must be connected to ground in the manner described in the installation Operation manual and before operating the equipment Frame or chassis terminal A conne...

Page 10: ...APC 7 R is a U S registered trademark of the Bunker Ramo Corporation viii...

Page 11: ...t 1 1 Speci cations 1 2 2 Initial Inspection Introduction 2 1 Initial Inspection 2 1 Repackaging the Test Fixture For Shipment 2 2 3 Service Introduction 3 1 Replaceable Parts 3 1 Parts Replacement Pr...

Page 12: ...Material Size Using with 16453A 1 2 2 1 16453A Contents 2 2 3 1 Replaceable Parts List Upper Part 3 2 3 2 Replaceable Parts List Lower Part 3 3 3 3 Replaceable Parts List Misc 3 4 3 4 Fixture Impedanc...

Page 13: ...urement procedures using the 16453A see the 4291A RF Impedance Material Analyzer User s Guide Product Description The 16453A is a xture for measuring the permittivity of dielectric materials Applicabl...

Page 14: ...nformation that is useful in applying the instrument by giving non warranted performance parameters These are denoted as typical typically nominal or approximate Applicable MUT Material Under Test Siz...

Page 15: ...by carefully performing an incoming inspection to check the dielectric material test xture set for signs of physical damage and missing contents If any discrepancy is found notify the carrier and Agil...

Page 16: ...This value is required to perform 4291A load compensation Repackaging the Test Fixture For Shipment If shipment to a Agilent Technologies service center is required each test xture should be repackag...

Page 17: ...terial Test Fixture Replaceable Parts Table 3 1 Table 3 2 and Table 3 3 identify the replaceable parts The parts listed in these tables can be ordered from your nearest Agilent Technologies o ce Order...

Page 18: ...460 2384 1 Spring 6 16453 01211 1 Plate 7 16453 23003 1 Dial 8 16453 24003 1 Screw 9 16453 04001 1 Cover 10 0515 0914 2 Screw M3 L6 11 16453 23001 1 Knob Shaft 12 16453 23002 1 Sleeve 13 3030 0285 1 S...

Page 19: ...53 24011 1 Flange 23 1250 0816 1 Contact 24 16453 60001 1 Bead Assembly 25 16453 24018 1 Electrode 26 1480 0739 2 Spring Pin 27 0515 0914 2 Screw M3 L6 28 16092 21010 2 Pin 29 16453 01212 1 Plate 30 1...

Page 20: ...ement Procedures This section provides removal and replacement procedures for the 16453A Note In this section numbers quoted by correspond to Reference Designators in the Replaceable Parts Lists Table...

Page 21: ...tact 23 and electrode 25 are locked with thread sealant Note Contact 23 and electrode 25 are not reusable after disassembly Upper Part Disassembly 12 Disassemble spring 18 insulator 19 and electrode 2...

Page 22: ...NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN POINT AVG ON off 4 Set sub markers to each frequency point in Table 3 4 5 Press the latch button while pulling up the knob so that the knob is latched 6 Read Cp...

Page 23: ...This information is subject to change without notice Keysight Technologies 1994 1999 2000 2015 February 2015 16453 90010 16453 90010 www keysight com...

Reviews: