background image

User Manual

 

Thank you for purchasing Keyking products. Please read before installing.

 

 

 

 

FPC-1000 Fingerprint stand alone 

  – networked door controller 

 

 

 

 

 

Summary of Contents for BioUSB10P

Page 1: ...User Manual Thank you for purchasing Keyking products Please read before installing FPC 1000 Fingerprint stand alone networked door controller...

Page 2: ...14 3 4 TCP IP Network 15 Chapter 4 On Device Configuration Menu 16 4 2 Personnel Management 18 4 2 1 Add Personnel Administrator 18 4 2 2 Delete Personnel 23 4 2 3 Delete All 23 4 2 4 Modify 24 4 3 N...

Page 3: ...3 of 43 3 5 Door Open Mode 40 Chapter 5 Operation in Sphinx 41 5 1 Install driver for BioUSB10 41 5 2 Select FPC1000 Series 41 5 3 Search Config FPC1000 41 5 4 Enrolling finger for user 41 5 5 Transf...

Page 4: ...Networked Door Controller Same installation as Stand Alone with the addition of network connection to the SPHINX This allow more advanced access control functionalities as well as sharing fingerprint...

Page 5: ...AWID Follow card up to 58BIT EM 2308 W26 W34 HID 1326 1386 According to card configuration W26 27 34 35 37 and so on KK KK243 250T W34 W50 P Multi Technology 125KHz Awid EM HID Prox Keyking and more...

Page 6: ...KEYKING GROUP FPC1000 Biometric Controller User Manual V1 00 Page 6 of 43 1 3 FPC Family...

Page 7: ...on as reader to standard access control controllers Wiegand 26 34 input for secondary reader as exit device Can be card reader or another FPC1000 unit Exit Button REX and Door Sensor inputs 3A Door Re...

Page 8: ...ns instruction 1 5 1 FPC1000 works as a reader Note Do Not connect FPC to door controller as reader connect only Wiegand wires to the controller Power the FPC from independent power supply 12Vdc 1A Do...

Page 9: ...iometric Controller User Manual V1 00 Page 9 of 43 1 5 2 FPC1000 works as a standalone 3 options Standalone no external reader Notes recommended power supply PSRFS1240 incorporate isolation relay and...

Page 10: ...r outdoor FPC1000 1 5 3 FPC1000 Location When selecting the location of installation make sure the following rules are followed No direct sun avoid over heating Protect from water splashes on the scre...

Page 11: ...Ensure that the wires can go freely and connect to the unit It is recommended to cut openings the same as on the back plate to allow the connectors and the wires to be stress free 2 1 4 Mount the back...

Page 12: ...EN Lock Open Keypad NO Key Description 0 9 0 9 Numerical Keys for menu selection and data entry 2 Esc Back to previous menu cancel operation 3 Door Bell energize Relay 2 4 Delete data entered 5 Scroll...

Page 13: ...tches IN1 AUX Input wire J2 NO1 Door Lock Relay See corresponding lock type for wiring COM1 NC1 NO2 AUX Programmable Relay Also act as Alarm and Alarm Clock COM2 NC2 J3 D1_Out Wiegand Output Signal D0...

Page 14: ...relay and backup battery support REX Exit Button o May be connected via the PSRFS1240 in such case do not use Door Sensor to prevent false alarms from the unit o Or direct to the FPC1000 using GND SEN...

Page 15: ...ING GROUP FPC1000 Biometric Controller User Manual V1 00 Page 15 of 43 3 4 TCP IP Network FPC1000 TCP IP network Figure 3 8 TCP IP crystal head Figure 3 9 Figure 3 2 RJ45 NO Definition 1 TX 2 TX 3 RX...

Page 16: ...e Configuration Menu Below is the full configuration menu New units do not have Administrator and will allow entering the menu without password or 1234 After first Administrator is enrolled to enter t...

Page 17: ...oll Users and Administrators When enrolling note the instructions on the screen 4 1 5 To make changes to other features and functions see the menu tree on page 15 4 1 6 More options and features are a...

Page 18: ...Info 6 7 4 2 Personnel Management 4 2 1 Add Personnel Administrator 1 Press Menu to enter management menu when FPC1000 is idle Esc works as cancel while Enter works as confirm 2 Press 1 to enter User...

Page 19: ...provide higher security but might result in multiple attempts by authorized users Lower number will make the unit faster to response and comply with problematic fingers but might authorize unauthorize...

Page 20: ...ext screen Level 1 1 apply to Card Fingerprint mode ONLY The number represent how strict the verification is done 4 is normal higher number will provide higher security but might result in multiple at...

Page 21: ...se and comply with problematic fingers but might authorize unauthorized persons False Positive FP Card mode prevent false positive Hit ENTER to go to the next screen 4 Follow the instructions on the s...

Page 22: ...2 1 5 User ID card 1 Press 5 to enter add UserID Card This mode uses Dual Factor ID though do not use Fingerprint as one of the identifications It is not recommended to use this mode unless there is...

Page 23: ...erminal Info 2 3 Keyking FPC1000 1 Add 2 Delete 3 Modify 4 Add Admin 5 Delete All Keyking FPC1000 Delete all Y 1 N 2 4 2 2 Delete Personnel 1 Enter the main menu and select 1 User 3 Press 2 Delete 4 E...

Page 24: ...OD 123456 Keyking FPC1000 1 User 2 Network 3 Option 4 Device 5 Terminal Info 2 3 Keyking FPC1000 1 Add 2 Delete 3 Modify 4 Add Admin 5 Delete All Keyking FPC1000 Input UserID MOD 123456 4 2 4 Modify 1...

Page 25: ...or updates from time to time make sure the laptop has static ip also so the FPC1000 will automatically recognize it when connected Single laptop can be used to configure multiple FPC1000 units See SPH...

Page 26: ...SC key to go back to previous Network Configuration menu Keyking FPC1000 1 Terminal ID 2 Net Configure 3 IP Address 4 Subnet Mask 5 Gateway 6 Host IP 7 Host Port Keyking FPC1000 1 User 2 Network 3 Opt...

Page 27: ...3 Enter IP Address interface button is Delete Backspace button is and ENTER to confirm Use ESC to go back to previous Network Configuration menu Keyking FPC1000 IP Address 192 168 x x Keyking FPC1000...

Page 28: ...Mask 3 Enter Subnet Mask button is Delete Backspace button is and ENTER to confirm Use ESC to go back to previous Network Configuration menu Keyking FPC1000 Subnet Mask 255 255 x x Keyking FPC1000 1 T...

Page 29: ...t Mask 3 Enter Gateway button is Delete Backspace button is and ENTER to confirm Use ESC to go back to previous Network Configuration menu Keyking FPC1000 1 User 2 Network 3 Option 4 Device 5 Terminal...

Page 30: ...Network 3 Select 4 to enter Subnet Mask 4 Enter Gateway button is Delete Backspace button is and ENTER to confirm Use ESC to go back to previous Network Configuration menu Keyking FPC1000 1 Terminal I...

Page 31: ...2 Network 2 Select 7 Host Port 3 Enter Port number button is Delete Backspace button is and ENTER to confirm Use ESC to go back to previous Network Configuration menu Keyking FPC1000 1 Terminal ID 2...

Page 32: ...creen Saver 4 Door Relay 5 MultiFP Verify 6 Tamper Alarm Keyking FPC1000 Clock Setting 20170103130923 4 4 Option 4 4 1 Language 1 In Main Menu select 3 Option 2 Select 1 Language 3 Select language 0 E...

Page 33: ...dark if no key or finger had been pressed It is important to select the right time to allow reasonable time to read the screen for users and at the same time to conserve energy by turning off the scre...

Page 34: ...Too long others unauthorized may be able to enter following authorized entrance tailgating Door Status is the Door Sense input Usually a magnet relay such as used in alarm systems It is not mandatory...

Page 35: ...cuts paper cut cracked skin on their enrolled finger having two or more fingers enrolled will allow entrance in such cases Multiple Fingerprint enrollment is possible only using SPHINX software for en...

Page 36: ...the whole unit Some can be personalized during the enrollment process to match personal conditions It is recommended to NOT make any changes unless needed to 1 From the Main Menu select 4 Device 2 Se...

Page 37: ...etting Use this setting if connecting the FTP1000 as Fingerprint Reader to a Door Controller using Wiegand Protocol This type of connection provides higher security operation where the door is control...

Page 38: ...No UserID 6 CardNo UserName 7 CardNo Name UserID 4 5 3 Card Number Mode Card Number Mode set the display of the card number on the screen Display Mode 4 7 It does not affect the operation of the FPC10...

Page 39: ...PC1000 1 User 2 Network 3 Option 4 Device 5 Terminal Info 6 7 Keyking FPC1000 Device ID 0001 Version 1 00 Language English MAC 00 10 F0 00 43 1D IP 192 168 4 207 8 4 5 5 Terminal Initialize 1 From Dev...

Page 40: ...emains closed Note Only the registered personnel can pass verifying 2 FP Card Application Flash a registered card or FP FPC1000can control a door by FP Card 3 FP Card Application Flash a registered ca...

Page 41: ...go to Setup menu and select communication configuration 2 Select the fingerprint tab 3 Select FPC1000 Series 5 3 Search Config FPC1000 1 run the Controller Configuration process as any other controlle...

Page 42: ...43 5 5 Transfer to FPC1000 terminal 5 6 FPC1000 setting Here you can change the Company name and everything When you click Apply then done Company Name Default Welcome to Use Tamper Alarm Display Mode...

Page 43: ...rmation Verify enrollment Verify network connection 4 Can not open door by flashing card or FP Lock power problem Enrolment problem Access level not enabled check lock power and wiring Check enrolment...

Reviews: