8
9
[Current Master Code] (#) (9) (8) (1)
[New Sub-Master Code] [New Sub-Master Code]
EXAMPLE:
Assuming that the current Master Code is (1) (2) (3)
(4) (5) and you want to add a Sub-Master Code of
(2) (3) (4) (5) (6).
1. Press (1) (2) (3) (4) (5)
●
(#) (9) (8) (1)
●
(2) (3) (4)
(5) (6)
●
(2) (3) (4) (5) (6)
●●
2. The unit will unlock upon entering the Master
Code and will remain unlocked while initiating the
program sequence.
3. Wait at least 5 seconds before trying your new
Sub-Master Code.
W) ADD/CHANGE SUB-MAS-
TER CODE: PROGRAM 981
EXAMPLE:
Assuming that the current Master or Sub-Master
Code is (1) (2) (3) (4) (5) and you want to set the
Pass time to 7 seconds.
1. Press (1) (2) (3) (4) (5)
●
(#) (9) (0) (7)
●●
2. Pass time is now set to 7 seconds.
Disable all 90 Users and 5 Service Codes, while
managers remain active. If a new user is added
while the unit is in “Disable Users” mode, the new
user will overwrite the previous stored code and
will automatically be enabled.
[Master/Sub-Master Code] (#) (9) (3) (#)
EXAMPLE:
Assuming that the current Master or Sub-Master
Code is (1) (2) (3) (4) (5) and you want to disable all
the Users.
1. Press (1) (2) (3) (4) (5)
●
(#) (9) (3) (#)
●●
2. All Users are now disabled.
O) DISABLE USERS ONLY:
PROGRAM 93#
Master and Sub-Master can enable this feature.
Once enabled, the unit is unlocked continuously.
[Master/Sub-Master Code] (#) (9) (6) (1)
EXAMPLE:
Assuming that the current Master or Sub-Master
Code is (1) (2) (3) (4) (5) and you want to enable
passage mode.
1. Press (1) (2) (3) (4) (5)
●
(#) (0) (2) (1)
●●
2. Unit is now unlocked until “Disable Passage
Mode” is initiated.
P) ENABLE PASSAGE
MODE: PROGRAM 961
Master and Sub-Master can disable the “Passage
Mode” feature. Once initiated, the unit is back to
its normal operation.
[Master/Sub-Master Code] (#) (9) (6) (2)
EXAMPLE:
Assuming that the current Master or Sub-Master
Code is (1) (2) (3) (4) (5) and you want to disable
passage mode.
1. Press (1) (2) (3) (4) (5)
●
(#) (9) (6) (2)
●●
2. Unit is now in its normal operation.
Q) DISABLE PASSAGE
MODE: PROGRAM 962
Normal Key press Sound + LED (Default)
[Master/Sub-Master/Manager Code] (#) (9) (7) (1)
Click! Key press Sound + LED
[Master/Sub-Master/Manager Code] (#) (9) (7) (2)
LED Only
[Master/Sub-Master/Manager Code] (#) (9) (7) (3)
S–V) KEY PRESS SOUND OPT-
ION: PROGRAM 971, 972, 973
Assuming that the current Master Code is (1) (2) (3)
(4) (5) and you want to change it to (4) (4) (4) (4) (4).
[Current Master Code] (#) (9) (9) (1) [Length of new
Master Code] [New Master Code] [Length of new
Master Code] [New Master Code]
EXAMPLE: Assuming that the current Master Code
is (1) (2) (3) (4) (5) and you want to change it to (4)
(4) (4) (4) (4).
1. Press (1) (2) (3) (4) (5)
●
(#) (9) (9) (1)
●
(5)
●
(4) (4)
(4) (4) (4)
●
(5)
●
(4) (4) (4) (4) (4)
●●
2. Wait for at least 5 seconds before trying your
new Master Code.
NOTE: The BLUE DOTS (
●
) indicates the flashing
BLUE LED on the unit. The unit will unlock
upon entering the Master Code and will remain
unlocked while initiating the program sequence.
Once the number of digits is selected, it cannot
be changed unless unit is reverted back to its
factory default settings.
Y) CHANGING THE MASTER
CODE: PROGRAM 991
Assuming that the current Master Code is (1) (2) (3)
(4) (5) and you want to delete a Sub-Master Code.
[Current Master Code]
●
(#) (9) (8) (2)
●
(9) (8) (2)
●●
1. Press (1) (2) (3) (4) (5)
●
(#) (9) (8) (2)
●
(9) (8) (2)
●●
2. Sub-Master Code is deleted.
X) DELETING SUB-MASTER
CODE: PROGRAM 982
GROUPS
Groups are designated group of locations in the lock’s
memory. This lock has 10 groups (0-9) and each group
consists of 1 manager and 9 users under it.
GROUP TABLE
MASTER
SUB-MASTER
GROUPS
0
1
2
3
4
5
6
7
8
9
MANAGERS
00
10
20
30
40
50
60
70
80
90
USERS
01
11
21
31
41
51
61
71
81
91
02
12
22
32
42
52
62
72
82
92
03
13
23
33
43
53
63
73
83
93
04
14
24
34
44
54
64
74
84
94
05
15
25
35
45
55
65
75
85
95
06
16
26
36
46
56
66
76
86
96
07
17
27
37
47
57
67
77
87
97
08
18
28
38
48
58
68
78
88
98
09
19
29
39
49
59
69
79
89
99
MANAGERS
1 manager is assigned to each group. There are 9 User
Codes that each Manager can program in its group. For
instance, Manager “00” in Group “0” can input User Codes
at locations “01” to “09”. Manager “10” in Group “1” on the
other hand can input User Codes at locations “10” to “19”.