background image

Create and delete User cards ( only for single user mode ) 

  

CREATE: 
                  Approach the Master card followed by the new User card. 
                  Up to 50 User cards can be created per lock.  
                  Green LED and long beep = User card created successfully. 
                  Red LED and 3 short beeps = User card not created. 
 

 

DELETE: 
                  Approach the Master card followed by the User card. 
                  Red LED 3 fast blinks and 3 short beeps = User card deleted. 

  

TRONIC MIFARE 

www.keya.cat 

Not OK: Red LED and 3 short beeps 

 

Correct card 

Wrong card 

OK: Green LED 1 long beep.

 

Summary of Contents for TRONIC MIFARE

Page 1: ...TRONIC MIFARE...

Page 2: ...TRONIC MIFARE 2 www keya cat...

Page 3: ...TRONIC MIFARE MANAGEMENT CARD MASTER CARDS USER CARDS www keya cat 3...

Page 4: ...er cards MASTER CARD Functions Create Delete User cards Single user only Inspection mode and Delete User cards USER CARD Functions Open Close locks SETTINGS CARD Functions Transfer parameters from sof...

Page 5: ...ps Master card not created DELETE Approach the Management card followed by the Master card Red LED 3 fast blinks and 3 short beeps Master card deleted 1 Create and delete Master cards TRONIC MIFARE ww...

Page 6: ...eated per lock Green LED and long beep User card created successfully Red LED and 3 short beeps User card not created DELETE Approach the Master card followed by the User card Red LED 3 fast blinks an...

Page 7: ...er card 1 time Green LED and long beep Lock opens during 30 seconds After inspection time lock closes automatically User card is not deleted 5 DELETE USER CARD Approach the Master card 2 times Green L...

Page 8: ...user mode Approach the Master card 4 times All User cards of this lock have now been deleted Delete User cards 7 Approach the Master card 5 times followed by the Used card to be delete 3 short beeps U...

Page 9: ...options Leave door open Close door again ACOUSTIC SIGNAL VOLUME High Low Off LED INDICATION OF CLOSED POSITION On Off blinking red LED when locker is closed CODES User Master LAST EVENTS BATTERY LEVEL...

Page 10: ...e place i e reception desk such as Create and delete management master user tags Read relevant information from the tag locker Nr user ID battery level Assign users to locks limiting time of use hours...

Page 11: ...10 200 Hz 2g Life test 200000 cycles Electrostatic discharge 8000 V Battery life 35000 cycles Measurements Torx T20 4 x AA LR6 Batteries replacement IMPORTANT The batteries replacement must be done i...

Page 12: ...ENG Rev3 775010...