KEY RK-2001W4 Operation Manual Download Page 8

8

domestic hot water system or the accumulative tank only are supported by the

regulator. If the additional pump is turned off or it works as the mixing pump, then there

is no possibility of changing the WINTER/SUMMER mode (the parameter is not

available).

CAUTION!!!

If the heating system is not equipped with accumulative tank, then when

a failure of the boiler sensor occurs, the temperature of the boiler water exceeds the

maximum value or the boiler overheating takes place, the central heating pump will be

turned on regardless of the working mode.

5.3. Domestic hot water tank working mode (bacteria eradication program) [cu u]

the regulator enables to activate the process of bacteria eradication in the domestic

hot water tank manually. After selecting the ‘d’ value, the boiler is going to reach the

temperature of 75°C in the domestic hot water tank. Once the temperature of 75°C in

the domestic hot water tank is obtained, the bacteria eradication programme will be

turned off automatically. The parameter is not available if the additional pump works in

a mode other than the domestic hot water mode.

CAUTION!

To prevent the users from being scalded, the option of bacteria eradication

should be switched on at night time when the water is not taken from the domestic hot

water tank.

5.4. The temperature measured with the additional sensor [u50°]

– the parameter

presents the temperature of the accumulative tank or the domestic hot water tank tem-

perature. If the additional pump is turned off or operates in the mixing pump mode,

then the parameter is not available.

5.5. The measured temperature of the exhaust gases [150°]

– the parameter is

available when the household thermostat input is switched to measurement of the ex-

haust gases temperature. In such case the above mentioned temperature is displayed.

6. Setting the parameters – service mode.

Holding the OK button for over 3 seconds will cause the regulator to enter the

viewing and setting parameters of the service mode. To view the parameters use the

buttons marked with ‘+’, ‘-’. After you have selected the particular parameter, it is

possible to enter the mode of change by pressing the OK button. This is signalized

with the blinking of the set value. The change of the parameter will occur after

pressing the ‘-‘ or ‘+’ button. To confirm the set value, press the OK button. Then the

regulator enables the user to select the next parameter. If it is not our intention to

change the parameter value with the + or - buttons, then select [End ] and press the

OK button or wait about 1 minute – the regulator will leave the service mode and the

temperature of the boiler water will be shown.

Summary of Contents for RK-2001W4

Page 1: ...OPERATION MANUAL RK 2001W4 SOLID FUEL FIRED BOILER TEMPERATURE CONTROLLER Wersja E128...

Page 2: ...or u50 8 The temperature measured emissions 150 8 Parameter setting the service mode 8 Table 2 Service parameters list 9 Pressure fan work parameters 10 Central heating pump parameters 11 Settings of...

Page 3: ...the regulator is shown in picture 2 CAUTION Before plugging in the controller first check if the wiring system is properly grounded and if the screw terminals of the output connector are tightened CA...

Page 4: ...he boiler If the regulator is out of the user s mode the temperature of the boiler water is shown on the display and the last symbol indicates the working mode status 50 stands for the STOP mode 50 C...

Page 5: ...rmostat input status If the exhaust gases sensor is connected then the central heating temperature equals the value set with the knob If the household thermostat is connected and its contacts are open...

Page 6: ...ng pump to turn on After the reason for the alarm has been removed it can be cancelled with the STOP button The E 2 error indicates that the boiler overheating has occurred The error will induce the b...

Page 7: ...eradication program u d u u50 Temperature measured with the additional sensor 150 The measured temperature of the exhaust gases End Exiting the user s mode The first column of the table shows the exem...

Page 8: ...at night time when the water is not taken from the domestic hot water tank 5 4 The temperature measured with the additional sensor u50 the parameter presents the temperature of the accumulative tank...

Page 9: ...1 C 2 A 99 Hysteresis of boiler temperature 90 99 1 C 99 Fd2h Fuel shortage testing time with burning 1 99 4h 1min 2h Fb2h Duration of fuel demand testing in working mode 1 99 4h 1min 2h Ar 0 Addition...

Page 10: ...programmed one If the parameter is set to then the gradual regulation of rotational speed is not available and the blower works with the capacity set with the parameter Setting the parameter between...

Page 11: ...of 30 seconds so that the water of the heating circulation should be mixed The parameter determines the time of restarting the pump The value means turning off the option 6 3 The sensor and additiona...

Page 12: ...of the boiler water is equal to or lower than the accumulative tank water temperature or when the temperature of the boiler water decreases below the L 65 minimum value The additional pump operating...

Page 13: ...nd in the working mode is activated when the temperature of the exhaust gases decreases below the c 90 value while the exhaust gases sensor is on or the temperature of the boiler water decreases below...

Page 14: ...st gases decreases by the value of the set hysteresis the regulator will start to increase the blower speed gradually Blower speed jump while stabilizing the temperature of the exhaust gases c F10 the...

Page 15: ...ler from the power supply remove the controller from the boiler chamber remove connectors and wiring from the regulator 8 Technical specification Power supply 230V 10 50Hz Power consumption blower and...

Page 16: ...16 Picture 2 Schematics of connecting the RK 2001W4 unit Picture 3 Schematics of connecting the additional devices...

Page 17: ...17...

Page 18: ...18...

Page 19: ...rchased the product DECLARATION OF CONFORMITY Manufacturer Przedsi biorstwo Wielobran owe KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 hereby declares that the product RK 2001W4 Controller is in con...

Page 20: ...Manufacturer P W KEY 11 200 Bartoszyce ul Bohater w Warszawy 67 tel 89 763 50 50 fax 89 763 50 51 www pwkey pl e mail pwkey onet pl...

Reviews: