6
7
Rx Unit:
➔
Using a short HDMI cable, connect your output / display device to the HDMI port
labeled “HDMI Output”.
➔
Connect the CAT5e/6 cable at the port labeled “CAT5e/6 Input”.
➔
If you are sending or receiving IR, connect it at this time
➔
If you are transmitting or receiving RS-232, connect to the RS-232 port
➔
Connect power to the Tx and Rx using the included power supplies and then
power up your source and display equipment.
Connections
Before making any connections, power off your source and display devices.
Tx Unit:
➔
Using a short HDMI cable, connect your source device to the HDMI port labeled
“HDMI Input”. To connect DVI or Display Port, use appropriate adapters.
➔
Connect the CAT6 STP cable that connects to the Rx Unit at the port labeled
“CAT5e/6 Output”.
➔
Make IR In and Out connections to receive (IR In port) or send (IR Out port)
control signals. Refer to the “Extending IR & RS-232 Control” for more information.
➔
Connect a DB9 cable for bi-directional RS-232 control.
Refer to the “Extending IR & RS-232 Control” for more information.
KD-X400ProK_X400POHK_Manual.indd 6-7
1/20/15 12:26 PM