Page 18
Page 19
Firmware Update
From time to time, Key Digital may provide firmware updates for the KD-VP2500. These updates
are optional, and should only be performed as instructed by Key Digital. Below is the procedure for
updating the firmware. Please note that incorrect update processes can result in an unusable unit.
Follow the detailed directions carefully.
Firmware Update Procedure
1.
Check our web site at www.keydigital.com for the latest firmware update ZIP file. Download
and unzip the firmware ZIP file to any directory on the PC. All of the unzipped files that are
created must be located in same directory on the PC.
2.
Be sure power is disconnected to the KD-VP2500 unit.
The power supply must be
disconnected (either from the back of the unit or from the wall outlet) to have a
complete power shutdown - reset.
3.
With power disconnected, set the rear-panel slide switch (see page 5 number 12) to program
mode “Mode A”.
Do not yet apply power to the unit.
4.
Connect an RS-232 cable to the COM1 serial port on the PC, and the other end to the RS-232
port on the rear panel of the KD-VP2500 unit. Make sure that no other devices are using the
COM1 serial port on the PC. Use of laptop computers has proven less reliable than desktop
systems. Please refrain from updating the firmware with laptops.
5.
Apply power to the KD-VP2500 unit.
The power supply must be reconnected to the unit.
6.
Double-click the ‘isynchd.bat’ file from within the ZIP folder. The command mode window
should pop up. Monitor this pop-up window to verify the update progress.
7.
If an error occurs, check the RS-232 connection and repeat all of the above steps.
8.
When the update is complete, disconnect the RS-232 cable between the unit and the PC.
9.
Disconnect power from the KD-VP2500 unit.
The power supply must be disconnected
(either from the back of the unit or from the wall outlet) to have a complete power
shutdown - reset.
10.
With the power disconnected, set the rear-panel slide switch to “Normal” mode.
11.
Turn on power to the KD-VP2500 unit.
Power supply must be reconnected to the unit
first; then push the ‘On” button on the front panel.
12.
The firmware update is now complete, and the KD-VP2500 is ready for operation. Upon boot-
up, the LCD will display the new firmware version
Mechanical
½
CE, RoHS, WEEE compliant
½
Rack Mountable 1U
½
Dimensions: 17” X 7.5” X 1.75”
½
Weight: 7 Lbs. (excluding power supply)
½
Enclosure: Black Metal
½
Power Supply: 6V DC @ 5 Amp (110-240V input 50/60Hz)
Important Product Warnings:
1.
Connect all cables before providing power to the unit.
2.
Test for proper operation before securing unit behind walls or in hard to access spaces.
3.
If installing the unit into wall or mounting bracket into sheet-rock, provide proper screw support
with bolts or sheet-rock anchors.
Safety Instructions.
Please be sure to follow these instructions for safe operation of your unit.
1.
Read and follow all instructions.
2.
Heed all warnings.
3.
Do not use this device near water.
4.
Clean only with dry cloth.
5.
Install in accordance with the manufacturer’s instructions.
6.
Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
7.
Only use attachments/accessories specified by the manufacturer.
8.
Refer all servicing to qualified service personnel. Servicing is required when the device has
been damaged in any way including:
»
Damage to the power supply or power plug
»
Exposure to rain or moisture
You MUST use the Power Supply provided with your unit or you VOID
the Key Digital
®
Warranty and risk damage to your unit and associated equipment.