Forced HPD Troubleshooting Tool
»
When ON, Hot Plug Detection voltage is fixed on to the connected display
»
Standard HPD behavior when set to OFF position
EDID Handshaking Rotary
»
EDID authentication is provided from the unit to the connected inputs/sources.
»
The EDID file (AKA “handshake”) is selected using the EDID rotary on the unit and provides a list
of compatible video and audio formats as well as digital data, informing the source device what it
should output.
»
Most sources will comply with a new EDID file without a power-cycle, but devices do behave
differently
»
Adjustments may speed up sync time during source selection.
Position EDID Handshake Description
EDID Rotary
0
Copy EDID from HDMI Output
Note: Default position
is “
A
”
1
1080i, 2CH AUDIO
2
1080i, DOLBY/DTS 5.1
3
1080i, HD AUDIO
4
1080p, 2CH AUDIO
5
1080p, DOLBY/DTS 5.1
6
1080p, HD AUDIO
7
4Kx2K@60, 10.2G, HDR, 2CH AUDIO
8
4Kx2K@60, 10.2G, HDR, DOLBY/DTS 5.1
9
4Kx2K@60, 10.2G, HDR, HD AUDIO
A
4Kx2K@60, 18G, HDR, 2CH AUDIO
B
4Kx2K@60, 18G, HDR, DOLBY/DTS 5.1
C
4Kx2K@60, 18G, HDR, HD AUDIO
IMPORTANT:
Please
apply light pressure
to the EDID rotary
when making your
selection.
D
1280x720p@60 DVI (no audio)
E
1920x1080p@60 DVI (no audio)
F
4Kx2K@30, 10.2G, HDR, 2CH AUDIO
IR Sensor
»
Used to collect line-of-sight IR from remote control
»
Receives signals from a 90° angle at up to 30ft away.
»
Mount an IR emitter from Compass Control Pro or to control by another professional control system
IR Remote Control
Model: KDRMSWPROK (uses CR2025 battery). Please note that some remote buttons may have no
functionality.
Discreet
Input Select
Incremental
Input Select
R1, R2, R3
(Reserved)
Device Select
(used for
addressing
mode)
Auto
Sensing
Enable
Auto Sensing Mode
Press the
AUTO
button on the IR remote control to enable Auto Sensing Mode
Auto Sensing mode is automatically disabled
when the KD-S2x1X/4x1X is manually controlled by
the front panel button or IR remote control. If fixed Auto Sensing is required, please contact Key Digital
Technical Support for a list of applicable models.
›
ON
» Unit will automatically select a newly detected active source. If current source is disconnected
or becomes inactive, auto sensing will sequentially advance to an active input/source
›
OFF
» Unit is in normal mode and regular switching functionality will occur