Key Digital FatBOY KD-MSA8X8 Operating Instructions Manual Download Page 6

KD-MSA8X8 Operating Instructions

Page 8

KD-MSA8X8 Operating Instructions

Page

RS-232 Control

The KD-MSA8X8 provides access to all functions when used with an RS-232 control system. 

Connection protocol is as follows:

Baud rate: 57600
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None

Key Digital provides a resource database for downloadable control modules at:  
www.keydigital.com/controlmain.aspx

The KD-MSA8X8 features AMX’s Device Discovery beacon.

When connected to qualifying AMX control systems via RS-232, the KD-MSA8X8 identifies itself so 
that the control system automatically loads the appropriate module.  This feature makes integrating 
into AMX RS-232 control systems incredibly simple.

The KD-MSA8X8 RS-232 cable pin out is as follows: 

RS-232 codes for the KD-MSA8X8

The commands are not case sensitive.  The command lines with spaces shown below are for easy 
recognition.  Spaces are not necessary when entering these command lines in the control system, 
though adding them for easy recognition will have no negative effect.

1. I/O Switching Set:

‘SP Oxx SI yy’

  (Oxx= the letter ‘O’ followed by the number Zero then xx)

xx = output select [01~08]
yy = input select [01~08]

Example:

 To set output 3 to input 7, issue the command line: ‘SPO03SI07’

Pin 2 – Transmit

Pin 3 – Recieve

Pin 5 – Ground

2. unit Address Set:

‘SP C A xx’

xx = the desired 2-digit unit address [00~99]. 00 is used for stand-alone configuration.

Example:

  To change the unit’s address to 2, issue the command line: ‘SPCA02’

3. IR Sensor Enable/Disable:

Enable: 

‘SP C IR E’

 

Example:

 To enable IR response for the unit, issue the command line: ‘SPCIRE’

Disable:

 ‘SP C IR D’

 

Example:

 To disable IR response for the unit, issue the command line: ‘SPCIRD’

4. Front Panel Button Enable/Disable:

Enable: 

‘SP C FB E’

 

Example:

 To enable front panel push button response for the unit, issue the command line: 

‘SPCFBE’
Disable: 

‘SP C FB D’ 

Example:

 To disable front panel push button response for the unit, issue the command line: 

‘SPCFBD’

5. Output Audio Mute/un-Mute: 

 

Mute: 

‘SP Oxx CM E’

 (Oxx= the letter ‘O’ followed by the number Zero then xx)

xx = output select [01~08] 

Example:

 To mute audio on output 2, issue the command line: ‘SPO02CME’

Un-Mute: 

‘SP Oxx CM D’

 (Oxx= the letter ‘O’ followed by the number Zero then xx)

‘xx’= output select [01~08] 

Example:

 To un-mute audio on output 5, issue the command line: ‘SPO05CMD’

6. All Outputs Mute/un-Mute: 

 

Mute: 

‘SP C CM E’

 

Example:

 To mute audio on all output channels, issue the command line: ‘SPCFBE’

Un-Mute: 

‘SP C CM D’

 

Example:

 To un-mute audio on all output channels, issue the command line: ‘SPCFBD’

7. Reset unit:

‘SP C DF

 

Example:

 To reset the unit to factory default, issue the command line: ‘SPCDF’

8. Output Status Query:

‘ST Oxx’

  (Oxx= the letter ‘O’ followed by the number Zero then xx)

‘xx’= output select [01~08]

Example:

 To issue a query for the current status of audio output 5, issue the command line: 

‘STO05’ 

KD-MSA8x8_Manual.indd   8-9

9/4/07   12:22:44 PM

Summary of Contents for FatBOY KD-MSA8X8

Page 1: ...e total video system solutions because we know and help drive the technology the industry the business and all the latest up and coming standards But most of all we know exactly what you need for your unique application the right solution Rev 0 Sept 2007 The KD MSA8X8 is a full matrix audio switcher capable of integrating up to 8 inputs or sources with 8 outputs or zones The unit directly accepts ...

Page 2: ... Guide Begin with the KD MSA8X8 and all input output devices turned off with power cables removed Connect audio sources to appropriate input ports on the KD MSA8X8 Connect audio outputs to amplifier display or other receiving device Connect power to the KD MSA8X8 as well as all other input and output devices and turn them on Operate KD MSA8X8 switcher via front panel buttons IR remote serial IR or...

Page 3: ...rs Multi channel analog surround signals accommodated using two input ports and two output ports thereby creating a 4X4 surround matrix switcher The digital audio path can also pass encoded signals such as AC3 DTS etc Additional Key Features Front panel LED input output assignment confirmation Easily controlled via IR remote included with discrete codes Serial IR and RS 232 RCA style connectors fo...

Page 4: ...ector a This connector has two functions It serves as a serial communication port for connection to RS 232 based control systems and also for firmware updates via serial connection to a standard PC See page 8 for RS 232 control protocol and page 11 for firmware update procedure Front Panel Features 1 Input select button a Press this button to cycle through inputs sequentially from 1 8 2 LED Input ...

Page 5: ...an be made in the following manner 3 Press the number keypad buttons 01 08 to select the desired output to switch Note that the LED s will flash indicating selected output 4 Then press the number keypad buttons 01 08 to select the desired input Note that the LED s will change indicating selected input For all IR commands the steps 1 and 2 above must be issued first to address the unit See the foll...

Page 6: ... digit unit address 00 99 00 is used for stand alone configuration Example To change the unit s address to 2 issue the command line SPCA02 3 IR Sensor Enable Disable Enable SP C IR E Example To enable IR response for the unit issue the command line SPCIRE Disable SP C IR D Example To disable IR response for the unit issue the command line SPCIRD 4 Front Panel Button Enable Disable Enable SP C FB E...

Page 7: ...he power button on the rear panel must be out or off to have a complete power shutdown reset With power off set the rear panel slide switch see page X number 12 to Program mode Do not yet apply power to the unit Connect an RS 232 cable to the COM1 serial port on the PC and the other end to the RS 232 port on the rear panel of the KD MSA8X8 unit Make sure that no devices are using the COM1 serial p...

Page 8: ...his apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wid...