17
EN
SAFETY AND CONTROL DEVICE CONNECTIONS
1
SIGNAL
Antenna - signal -
2
SHIELD
Antenna - shield -
3
PH1
Photocells (closing), NC contact between PH1 and COM. The photocell is tripped at any time during closing of the
automation system, halting operation immediately and reversing the travel direction
4
STOP
STOP safety device, NC contact between STOP and COM. This input is classified as a safety device; the contact
can be deactivated at any time, cutting out the automation system and disabling all functions, including Automatic
Closure
5
COM
Common for the
PH1, STOP, SS, OPEN, CLOSE
inputs
6
SS
STEPPING
command NO contact between SS and COM
Open/Stop/Close/Stop command
7
24 Vac
24 Vac accessories power
1,5 W
8
24 Vac
24 Vac accessories power 1,5 W
9
CLOSE
CLOSE command NO contact between CLOSE and COM
Contact for the HOLD-TO-RUN function. The gate CLOSES as long as the contact is held down
With J5 JUMPER close: closing limit switch
10
OPEN
OPEN command NO contact between OPEN and COM
Contact for the HOLD-TO-RUN function. The gate
OPENS as long as the contact is held down
With J5 JUMPER close: opening limit switch
4.2 - Product installation
KEY
CONTROL UNIT
LED
A.R
W.T
CD.
LED STATUS
FLASHING
CONSTANTLY LIT
CONTROL UNIT KEY
SELECTION
MODE
TRASMISSION
It’s not possibile to enter in the configuration menu with the automation in movement.
IT IS NECESSARY THAT THE AUTOMATION IS CLOSED!
4.3 - Remore control setting
1
2
3
4
LEARNING:
1) Press the SELECTION key, the CD. led is now flashing
2) Press the radio control key “1”. The control unit memorised auto
-
maticaly the second key “2” (Can be used like pedestrian run). When
the code led remains lit the learning operation is finished.
CANCEL:
1) Press the SELECTION key until the CD. led is flashing.
2) Press the MODE key. All the leds are now lit and at the end all the
codes of the learned
transmitters will be deleted (the CD. led remain
off).
PRESS ONE TIME SELECTION
CD.
CD.
1
2
3
4