68
www.kewtechcorp.com
69
www.kewtechcorp.com
www.kewtechcorp.com
COMMENTS
This option allows the User to determine if the Comments field will be
available at the end of a test.
ALWAYS – Comments always available at the end of test
ON PASS – Comments only available if the Appliance passed the test.
ON FAILURE - Comments only available if the Appliance failed the test.
NEVER – Comments will not be available at the end of the test.
Default is ALWAYS
APLNCE & CMNTS
This allows the user to set the number of characters available for the
appliance number and comments.
Options are:
APP = 10,
CMNTS = 20
APP = 15,
CMNTS = 20
APP = 10,
CMMTS = 10
Default is APP = 10, CMNTS = 20
COMENTS LINE 1 – 4
These options allow the User to designate each Comment line as a
specific field for use with PATGuard Plus software. Options are: ASSET
DESCRIPTION, ASSET GROUP, MAKE, MODEL, SERIAL NUMBER, NOTES.
These should be set to correspond to the settings in PATGuard Plus.
Default is COMENTS LINE 1 – ASSET DESCRIPTION,
COMENTS LINE 2 – NOTES,
COMENTS LINE 3 – NOTES,
COMENTS LINE 4 – NOTES.
These correspond with the default settings in the PATGuard software.
PAT manager software only recognises LINE1 – ASSET DESCRIPTION. This
should be used for the appliance description.
HOW TO PRINT BARCODE LABELS AND TESTCODES
AFTER TEST
The options set here determine the next action all the test results are saved
to memory. Options are: OPTIONS – Displays the OPTIONS menu giving the
User further choices.
NEW TEST – Will display the ENTER APPLIANCE DETAILS screen to
immediately commence the next test.
DOWNLOAD, NEW TEST – Will Download the test results with out further
prompting and display the ENTER APPLIANCE DETAILS screen to
immediately commence the next test. When this option is chosen a further
option is required to CONFIGURE the Download.
Default is OPTIONS.
DATE AND TIME
This allows the user to password protect the date and time. An existing
password must be setup before this option will become effective.
USER LIST
This allows the user to password protect the USER LIST. An existing
password must be setup before this option will become effective.