9. Cleaning and storage

  

Tester does not need any special maintenance 

if used according to user manual.
  

Remove tester from all test points before 

cleaning.
  

Use a lightly damp cloth with neutral detergent 

for cleaning the instrument. Do not use  abrasives 
or solvents. 
  

Do not expose the instrument to direct 

sun light, high temperature and humidity or 
condensation. 
  

Remove batteries when the instrument will not 

be in use for a long period. 

7. Battery replacement

 

Remove the probes from any testing point, 

when opening the battery case. 
  

Short the probe tips before any testing to 

verify battery status. 
Voltage level detection is possible without batteries 
but the buzzer and the single pole LED will not 
operate.

Follow the procedure below and replace 
batteries with new ones (type IEC LR03 /  
AAA 1.5V). 

•  Unscrew the battery case, with a screwdriver.
•  Pull out the battery case and replace the 
batteries. Insert new batteries according to the 
engraving on the battery case. 
•  Re-assemble battery case.
  

Confirm that the battery case is properly 

locked prior to measurements.

8. Technical data

•  Voltage range: 12…690V AC (40…70Hz), DC(±)
•  LED Nominal voltage: 

12/24/50/120/230/400/690V, AC (40…70Hz), 
DC(±)

•  LED tolerances according to EN61243-3
•  Response time: < 0.5s at 100% of each nominal 

voltage 

•  Peak current: Is<3.5mA (at 400V) 
•  Measurement Duty: 30s ON (operation time), 

240s OFF (recovery time) 

•  Internal battery consumption: Approx. 80mA 
•  Single-pole phase test voltage range: 100…690V 

AC (50/60Hz) 

•  Continuity test: Detection range 0…500kΩ + 50% 
•  Battery: 3V (IEC R03  / AAA 1.5V x 2) 
•  Temperature: -15…55°C operation; -20…70°C 

storage, No condensation 

•  Humidity: Max 85% RH 
•  Altitude up to 2000m 
•  Overvoltage category: CAT III 600V / CAT II 690V
•  Standard EN61243-3:2014
•  Pollution degree 2 
•  Protection: IP 54

9

8

Summary of Contents for KT1710

Page 1: ...kewtechcorp com KT1710 Voltage Tester Manual KT1710 VOLTAGE TESTER ...

Page 2: ...fety Measures 3 Danger of electric shock and other dangers 4 Intended Use 5 Tester Information 6 Carrying out Measurements 6 1 Preparation and Safety 6 2 Voltage Test 6 3 Single pole Phase Test 6 4 Continuity Test 7 Battery Replacement 8 Technical Data 9 Cleaning and storage 1 ...

Page 3: ...equired for safe operation and use of the tester Before using the tester read the operating instructions carefully and follow them in all respects 2 Safety Measures Warning of a potential danger comply with instruction manual Reference Please pay utmost attention Caution Dangerous voltage Danger of electrical shock Continuous double or reinforced insulation Conformity symbol the instrument complie...

Page 4: ...lways check that the tester is in perfect working order e g on a known voltage source Do not use the tester if one or more functions fail or if no functionality is indicated It is not permitted to use the tester during rain or precipitation Correct measurement is guaranteed only within a temperature range of 15 C to 55 C at a relative air humidity of less than 85 If the safety of the user cannot b...

Page 5: ...ent capability of indicating the presence or absence of operating voltage in case of the presence of interference voltage A voltage detector of relatively low internal impedance compared to the reference value of 100 kΩ will not indicate all interference voltages having an original voltage value above the ELV level When in contact with the parts to be tested the voltage detector may discharge temp...

Page 6: ...es with new ones type IEC LR03 AAA 1 5V Unscrew the battery case with a screwdriver Pull out the battery case and replace the batteries Insert new batteries according to the engraving on the battery case Re assemble battery case Confirm that the battery case is properly locked prior to measurements 8 Technical data Voltage range 12 690V AC 40 70Hz DC LED Nominal voltage 12 24 50 120 230 400 690V A...

Page 7: ...ranty enhances the customers legal rights it covers all manufacturing defects for a two year period but Kewtech reserves the right to exclude abuse or accidental damage To register your free guarantee simply go to kewtechcorp com the link is on the home page Re calibration Service Regular re calibration is recommended for this instrument Kewtech recommends that with normal use the instrument is ca...

Reviews: