KewlFlow™ POWER SUPPLY OPTIONS 
 

     Option #1 … 12V Connector (included) 
     Option #2 … Converter for 110VAC 
     Option #3 … Battery Pack 

 
PRECAUTIONS - Cooler Use 
 

Do not use anything but water (or water with a recommended cleaning agent) and ice (no dry 
ice) in the system. 
 
Do not operate dry - extended dry operation may damage the pump and will void the warranty. 
 
Do not put the entire inner container (with pump) into a freezer - the pump can be damaged if 
frozen. 
 
Power requirements are 10 to 15 Volts DC, 0.5 Amps maximum. 
 

FILLING 
 

1)  Unzip the cooler's outer shell and rotate the top backward. 
2)  Open the inner container by pushing down on the lid while lifting up and out on all four 

locking tabs. 

3)  Fill with ice to the top of the container if desired. 
4)  Add at least 16 ounces of water for system circulation. 
5)  The pump is auto-priming if submerged in at least 2 inches of water. 
6)  When replacing the lid, ensure that the gasket in the lid is firmly seated along the entire 

top edge of the container. 

7)  Press down on the lid while engaging the four locking tabs. 

 

POWER CONNECTIONS & OPERATION 
 

1)  Pull the Power Switch out of the pouch on the back of the 

cooler. 

2)  Connect the white Power Connector into the mating 

connector on the External Power Cord that was included with 
your cooler. 

3)  Plug the other end of the External Power Cord into a 12V 

accessory power outlet, or a 110VAC to 12VDC adapter. 

4)  Turn the pump on using the Power Switch. 
5)  You may see a small stream of water coming from the outlet 

“stem” of the pump if the water level is below it.  This is a 
normal function of the pump’s self-priming feature. 

 

DRAINING WATER BEFORE REFILLING WITH ICE 
 

There is no need to tilt the cooler over to drain out the water.  Instead, follow these steps for an 
easier way to drain the cooler: 
 

Summary of Contents for 6429

Page 1: ...S M L XL KewlFlow Cooler Colors Black Custom Sizes 9 Quart 4 5 Quart Thank you for purchasing a KewlFlow Circulatory Cooling System Please read all operating instructions before using your new system If you have any questions comments or suggestions please do not hesitate to contact us at 1 888 823 2665 Stay Kewl ...

Page 2: ... circulation 5 The pump is auto priming if submerged in at least 2 inches of water 6 When replacing the lid ensure that the gasket in the lid is firmly seated along the entire top edge of the container 7 Press down on the lid while engaging the four locking tabs POWER CONNECTIONS OPERATION 1 Pull the Power Switch out of the pouch on the back of the cooler 2 Connect the white Power Connector into t...

Page 3: ... the top of your pants at the center of your body as shown in the figure below Be sure to follow these instructions when making your Torso Length measurement 1 Have someone else measure you Attempting to do this by yourself may cause significant errors in the result 2 Wear the type of pants or shorts that you plan to use with the vest and wear them at the height that is normal for you For example ...

Page 4: ... allowing the vest to ride up higher on your abdomen Keeping the lowermost elastic straps tighter will help minimize this If the vest you get is too large the shirttails will tuck fully into your pants and the bottom end of the zipper on the vest may end up below the top of your pants If the end of the zipper is more than about 1 2 below the top of your pants the hose coming from the vest won t ma...

Page 5: ...de of the recommended range please do not flow water through the vest We will gladly exchange it for another size Please read our Return Policy at the end of this guide for details A return charge will apply if water flows through it so please be sure you have the right size before you flow water through the vest If you have verified that the vest length is correct but feel that it fits you too ti...

Page 6: ...r and how it works best By placing a layer of clothing over the vest you insulate it and yourself from the surrounding air keeping more of the cold inside to cool your body We recommend that bicyclists wear at least a thin jersey over the vest Leathers worn by motorcyclists are ideal KewlFlow Personal Cooling System Specification Fact Sheet What is it The KewlFlow Personal Cooling System is a self...

Page 7: ... with zippered front Shirttail design keeps vest in place during activity Quick disconnect fittings on a single flexible insulated hose for easy connection to backpack Warranty One year on all materials and workmanship Patent pending What is the KewlFlow Personal Cooling System and what does it do The KewlFlow Personal Cooling System is composed of a lightweight Cooling Vest through which ice chil...

Page 8: ...lder the ice you start with the better When you add water to that ice which is necessary for circulation through the pump and vest it warms up the ice so adding only a minimal amount of the coldest water possible ice water is best More body heat is generated by a person rigorously exercising than at rest More heat will be absorbed when the vest is worn tightly against bare skin as compared to loos...

Page 9: ... over the vest Otherwise you may cool the surrounding air more than you cool yourself See the FAQ for more information about wearing clothing over the vest Can I wear clothing over the vest Certainly That s what it was designed for and how it works best By placing a layer of clothing over the vest you insulate it and yourself from the surrounding air thus keeping more of the cold inside to cool yo...

Page 10: ...ngs from your chilled water supply source and replace with ours and you should be ready to go Will the KewlFlow Vest work with a HANS device Yes it should work fine We purposely routed the tubes connecting the front of the vest to the back as close as possible to the neck and not on the tops of the shoulders so that a HANS device would not pinch the tubes closed What maintenance is required Only p...

Reviews: