KEUCO Edition 400 51505 010050 Mounting Instruction Download Page 3

3

 

Important information, please read! 

US

 Technical speci

fi

 cations

 

– Flow at 60 psi pressure: 

approx. 1.2 gpm

 

– Pressure: 

min. 8 psi

recommended 14.5 - 72.5 psi

 

– Operating pressure: 

max 145 psi

 

– Test pressure: 

232 psi

 

– Recommended hot water inlet temperature:

 

max 149 F

 

– Water connection: 

 

cold = blue marked hose

 

hot = red marked hose

Avoid pressure differences between the cold and 
hot water feeds.
Install a pressure reducer for static pressures 
above 72.5 psi.

 

– Non reversible cartridge.

Installation dimensions, 

refer to page 2

Installation, 

refer to picture 1 on page 6

Flush potable water pipes thoroughly before and 
after installation.
Use only neutrally netting silicone.

Test connections for leaks with water pressure.

Operation, 

refer picture 9 to 11 on page 7

Servicing

, refer to picture 12 and 13 on page 7

Assemble in reverse order.

 

– Cartridge nut torque:  

8.9 - 9.6 lbf ft

For spare parts with order numbers, 

refer to page 11.

To obtain warranty repair or replacement Ser-
vice, please contact KEUCO Managment Inc. 
Service at: of

fi

 [email protected].

For warranty and care information please refer 
to the attached 

warranty and care instruc-

tions

.

These instructions are for both the installer for 
installation and the user for operation and main-
tenance of the product. After installation, please 
hand them over to the user to keep.

Symbols and explanations

 Attention! 

Warning against bodily injury or 

damage to property.

 Note, tip or reference

 Correct installation/test of functionality

Incorrect installation

Observe installation details

Cold water

Hot water

Water 

fl

 ow

No water 

fl

 ow

Intended use

Single lever mixer tap for use in bathrooms 
and WCs. Operation possible with pressure 
tanks and thermally and hydraulically controlled 
instantaneous water heaters. Operation with 
unpressurised tanks (open water heaters) is 

not

 

possible!
Operation only with potable water.

Product is only suitable for installation indoors!

Attention! 

Only install in frost-free places.

WARNING - 

California Prop 65

This product can expose you to chemicals 
including Nickel and/or Lead, which is/are known 
to the State of California to cause cancer/birth 
defects or other reproductive harm.
For more information go to: 

www.P65Warnings.ca.gov

 .

Summary of Contents for Edition 400 51505 010050

Page 1: ...ni per l installazione NL CS PL RU Montagehandleiding Návod k instalaci Instrukcja montażu Инструкция по монтажу Edition 400 74314_000 06 2018 US ES Mounting instruction Instrucciones de instalación CA Instructions d installation 51505 010050 51505 020050 51505 030050 51505 040050 51505 050050 51505 120050 51505 130050 ...

Page 2: ...rozměry Wymiary montażowe Установочные размеры max7 1 16 max180 179 Ø1 7 16 Ø36 14 1 2 360 Ø1 3 8 max1 9 16 max40 6 153 6 1 4 159 2 5 8 67 Ø1 7 8 Ø48 7 1 16 Ø2 1 2 1 1 15 16 25 50 7 3 4 197 Ø1 1 4 Ø32 Ø63 Ø35 3 8 comp 6 6 51505 XX0050 US Mounting dimensions ES Las dimensiones de montaje CA Dimensions de montage inch and mm pulgades y mm pouces et mm 45 45 ...

Page 3: ... Service at office usa keuco com For warranty and care information please refer to the attached warranty and care instruc tions These instructions are for both the installer for installation and the user for operation and main tenance of the product After installation please hand them over to the user to keep Symbols and explanations Attention Warning against bodily injury or damage to property No...

Page 4: ...io de KEUCO Managment Inc office usa keuco com En el pasaporte de mantenimiento y garantía adjunto encontrará indicaciones sobre la garantía y el mantenimiento Este manual está dirigido al instalador para el montaje así como al usuario para el manejo y mantenimiento del producto Por favor después de la instalación este manual se debe entregar al usuario para que lo conserve Símbolos y significado ...

Page 5: ...de voir page 11 Pour obtenir la réparation sous garantie ou le remplacemen veuillez prendre contact avec le Service à la clientèle de KEUCO Managment Inc office usa keuco com Les consignes relatives à la garantie et à l entretien figurent sur la carte d entretien et de garantie jointe Ces instructions sont destinées à l installateur pour effectuer le montage et pour l utilisateur pour utiliser le ...

Page 6: ...6 2 6 4 5 1 1 2 13mm 16mm 1 2 3 3 4 ...

Page 7: ...7 7 9 8 12 10 13 1 2 24mm 2 5mm 1 2 3 1 2 3 4 A B 1 9mm 2 11 6 _ ...

Page 8: ...8 ...

Page 9: ...9 ...

Page 10: ...10 ...

Page 11: ...erdelen CS PL RU Sada náhradních Zestaw części Запчасти 50100000495 50100XX0489 50100XX0494 50100000578 50100000491 50100000564 50100000565 50100XX0566 50100XX0038 50100010176 50100XX0496 50100000533 50100000225 XX 01 02 03 04 05 12 13 US Spare parts ES Piezas de recambio CA Liste de pièces 51505 XX0150 ...

Page 12: ...P4 2DT Phone 44 10442865220 E Mail admin keuco co uk FR KEUCO SARL 5 Rue du Martelberg F 67700 Monswiller Téléphone 33 3 88700200 E Mail bureau keuco fr NL KEUCO GmbH Co KG Kantoor Nederland Postbus 1286 5004 BG Tilburg Telefoon 31 88 6 333 999 E Mail info keuco nl RU KEUCO GmbH Co KG Представительство в России Космодамианская набережная дом 4 22 корпус Б 115035 Москва Электронная почта US KEUCO M...

Reviews: