Power Consumption
Input Voltage
Illuminator
19 VDC
Getting Started
Maintenance
Troubleshooting Guide
Product Specification
Step 1
Power
Step 3
Controlling Multiple A360X
Step 4
Mounting
Step 2
Control
Connect the A360X to the power adapter and
plug it into a wall outlet. Turn the Intensity Tuning
Knob (B) to the right to turn on the light.
• Turn the Intensity Tuning Knob (B) to adjust the
brightness of the fixture.
• Turn the Color Tuning Knob (F) to adjust the light
to the desired color.
• A360X can be connected and controlled through
Kessil Spectral Controller X with a Type-C USB
Cable (K-Link Cable).
• Connect two or more lights with K-Link Cables
as shown in the image.
• Multiple A360X lights can be controlled by either
a single external controller or manually.
• When controlling without an external controller,
tuning controls on any light control all other
lights in chain.
• Screw the Hanging Ring (D) into the
center screw hole.
• Hang the light with the two
Screw Hooks (C) and the two
Hanging Brackets (E).
• To install the Hanging
Brackets (E), remove the
screws on the A360X, use
the same screws to secure
the fasteners with triangular
rings onto the light fixture.
Problem
Make sure the unit is connected to the power adapter and the power
adapter is plugged into an outlet with the correct specifications.
Make sure the power adapter has the right specifications.
Make sure the unit has not overheated by operating at a room
temperature above 100°F/40°C.
Make sure electrical power is available to the AC outlet being used.
Make sure the power adapter has the right specifications.
Make sure the device is operating within the specified operating
temperature range. If unit overheats, it will automatically shut down.
Make sure the fan is operating properly.
Cause / Solution
1.Keep the air intake holes, Venting Holes (H), and fan clear of dust. To clean the fan, unplug the unit and
insert the tip of a CO2 dust blower (or similar dust blower) in one of the Venting Holes (H) on the unit's
outer shell. Hold and spray. You can also gently vacuum out the light through the venting holes.
2.Keep the Lens (I) clean. If the lens becomes contaminated with water, dust, or other particles, unplug
the unit and clean the lens with isopropyl alcohol. Wet a cotton swab or a napkin in isopropyl alcohol,
gently wipe the surface of the lens, and let it dry.
3.Keep plastic covers for K-Link ports plugged in when the ports are not in use. Keep the ports clean all
the time.
Please make sure to perform maintenance before doing any troubeshooting.
Light doesn’t turn ON
Unit is flickering
90W MAX
Input
Output
Listed Power Adapter
19 VDC, 4.74A
100-240 VAC, 47-63 Hz, 1.5 A MAX
Kessil Lighting
A DiCon Brand
1689 Regatta Blvd, Richmond, CA 94804
(510) 620-5250
www.kessil.com
(Controller X not included)
This is a LED light source emitting 40 % or more of total radiation
power of the range 250-800 nm in the range of 400-480 nm, and
intended for coral growth.
@kessilled
@kessil
kessil.com
kessil.led
kessiltube